Percutaneous epicardial access (PEA), performed on a beating heart under fluoroscopy, enables arrhythmia treatment. However, advancing a needle toward the thin and moving pericardium remains highly challenging and risky. To address this problem, we present a physics-driven sonification method for Extended Reality (XR)-based multisensory navigation to enhance user perception during the critical needle landing phase in PEA. Dynamic cardiac anatomy from 4D CTA was reconstructed and registered to a real-world coordinate system. Real-time needle tracking provided the position of the needle tip relative to moving cardiac structures and drove an audio-visual feedback module. The visual display presented navigational cues and dynamic anatomy, while the auditory display encoded physiological cardiac states using a multilayer physical membrane model. A phantom study was conducted with twelve cardiologists performing needle insertions under visual-only and multisensory feedback. The multisensory method significantly improved navigation safety ($χ^2 = 11.30$, $p < 0.01$), reducing myocardial contact (3.64% vs. 7.27%) and increasing correct access (90.91% vs. 52.73%). Needle placement accura
Percutaneous dilatational tracheostomy (PDT) is frequently performed on patients in intensive care units for prolonged mechanical ventilation. The needle puncture, as the most critical step of PDT, could lead to adverse consequences such as major bleeding and posterior tracheal wall perforation if performed inaccurately. Current practices of PDT puncture are all performed manually with no navigation assistance, which leads to large position and angular errors (5 mm and 30 degree). To improve the accuracy and reduce the difficulty of the PDT procedure, we propose a system that automates the needle insertion using a velocity-controlled robotic manipulator. Guided using pose data from two electromagnetic sensors, one at the needle tip and the other inside the trachea, the robotic system uses an adaptive constrained controller to adapt the uncertain kinematic parameters online and avoid collisions with the patient's body and tissues near the target. Simulations were performed to validate the controller's implementation, and then four hundred PDT punctures were performed on a mannequin to evaluate the position and angular accuracy. The absolute median puncture position error was 1.7 mm
3D ultrasound (US) imaging has shown significant benefits in enhancing the outcomes of percutaneous liver tumour ablation. Its clinical integration is crucial for transitioning 3D US into the therapeutic domain. However, challenges of tumour identification in US images continue to hinder its broader adoption. In this work, we propose a novel framework for integrating 3D US into the standard ablation workflow. We present a key component, a clinically viable 2D US-CT/MRI registration approach, leveraging 3D US as an intermediary to reduce registration complexity. To facilitate efficient verification of the registration workflow, we also propose an intuitive multimodal image visualization technique. In our study, 2D US-CT/MRI registration achieved a landmark distance error of approximately 2-4 mm with a runtime of 0.22s per image pair. Additionally, non-rigid registration reduced the mean alignment error by approximately 40% compared to rigid registration. Results demonstrated the efficacy of the proposed 2D US-CT/MRI registration workflow. Our integration framework advanced the capabilities of 3D US imaging in improving percutaneous tumour ablation, demonstrating the potential to exp
Background: While intravascular imaging, particularly optical coherence tomography (OCT), improves percutaneous coronary intervention (PCI) outcomes, its interpretation is operator-dependent. General-purpose artificial intelligence (AI) shows promise but lacks domain-specific reliability. We evaluated the performance of CA-GPT, a novel large model deployed on an AI-OCT system, against that of the general-purpose ChatGPT-5 and junior physicians for OCT-guided PCI planning and assessment. Methods: In this single-center analysis of 96 patients who underwent OCT-guided PCI, the procedural decisions generated by the CA-GPT, ChatGPT-5, and junior physicians were compared with an expert-derived procedural record. Agreement was assessed using ten pre-specified metrics across pre-PCI and post-PCI phases. Results: For pre-PCI planning, CA-GPT demonstrated significantly higher median agreement scores (5[IQR 3.75-5]) compared to both ChatGPT-5 (3[2-4], P<0.001) and junior physicians (4[3-4], P<0.001). CA-GPT significantly outperformed ChatGPT-5 across all individual pre-PCI metrics and showed superior performance to junior physicians in stent diameter (90.3% vs. 72.2%, P<0.05) and len
In percutaneous pelvic trauma surgery, accurate placement of Kirschner wires (K-wires) is crucial to ensure effective fracture fixation and avoid complications due to breaching the cortical bone along an unsuitable trajectory. Surgical navigation via mixed reality (MR) can help achieve precise wire placement in a low-profile form factor. Current approaches in this domain are as yet unsuitable for real-world deployment because they fall short of guaranteeing accurate visual feedback due to uncontrolled bending of the wire. To ensure accurate feedback, we introduce StraightTrack, an MR navigation system designed for percutaneous wire placement in complex anatomy. StraightTrack features a marker body equipped with a rigid access cannula that mitigates wire bending due to interactions with soft tissue and a covered bony surface. Integrated with an Optical See-Through Head-Mounted Display (OST HMD) capable of tracking the cannula body, StraightTrack offers real-time 3D visualization and guidance without external trackers, which are prone to losing line-of-sight. In phantom experiments with two experienced orthopedic surgeons, StraightTrack improves wire placement accuracy, achieving the
During Percutaneous Nephrolithotomy (PCNL) operations, the surgeon is required to define the incision point on the patient's back, align the needle to a pre-planned path, and perform puncture operations afterward. The procedure is currently performed manually using ultrasound or fluoroscopy imaging for needle orientation, which, however, implies limited accuracy and low reproducibility. This work incorporates Augmented Reality (AR) visualization with an optical see-through head-mounted display (OST-HMD) and Human-Robot Collaboration (HRC) framework to empower the surgeon's task completion performance. In detail, Eye-to-Hand calibration, system registration, and hologram model registration are performed to realize visual guidance. A Cartesian impedance controller is used to guide the operator during the needle puncture task execution. Experiments are conducted to verify the system performance compared with conventional manual puncture procedures and a 2D monitor-based visualisation interface. The results showed that the proposed framework achieves the lowest median and standard deviation error across all the experimental groups, respectively. Furthermore, the NASA-TLX user evaluatio
Navigation for thoracoabdominal puncture surgery is used to locate the needle entry point on the patient's body surface. The traditional reflective ball navigation method is difficult to position the needle entry point on the soft, irregular, smooth chest and abdomen. Due to the lack of clear characteristic points on the body surface using structured light technology, it is difficult to identify and locate arbitrary needle insertion points. Based on the high stability and high accuracy requirements of surgical navigation, this paper proposed a novel method, a muti-modal 3D small object medical marker detection method, which identifies the center of a small single ring as the needle insertion point. Moreover, this novel method leverages Fourier transform enhancement technology to augment the dataset, enrich image details, and enhance the network's capability. The method extracts the Region of Interest (ROI) of the feature image from both enhanced and original images, followed by generating a mask map. Subsequently, the point cloud of the ROI from the depth map is obtained through the registration of ROI point cloud contour fitting. In addition, this method employs Tukey loss for opt
Cancer cases have been rising globally, resulting in nearly 10 million deaths in 2023. Biopsy, crucial for diagnosis, is often performed under ultrasound (US) guidance, demanding precise hand coordination and cognitive decision-making. Robot-assisted interventions have shown improved accuracy in lesion targeting by addressing challenges such as noisy 2D images and maintaining consistent probe-to-surface contact. Recent research has focused on fully autonomous robotic US systems to enable standardized diagnostic procedures and reproducible US-guided therapy. This study presents a fully autonomous system for US-guided needle placement capable of performing end-to-end clinical workflow. The system autonomously: 1) identifies the liver region on the patient's abdomen surface, 2) plans and executes the US scanning path using impedance control, 3) localizes lesions from the US images in real-time, and 4) targets the identified lesions, all without human intervention. This study evaluates both position and impedance-controlled systems. Validation on agar phantoms demonstrated a targeting error of 5.74 +- 2.70 mm, highlighting its potential for accurately targeting tumors larger than 5 mm.
The increasing availability of wearable electrocardiography (ECG) devices enables the continuous monitoring of individual ECG alterations. This could be beneficial for patients suffering from acute ischemia but with non-standard ECG findings that do not fit to the subject-independent and absolute thresholds defined in clinical guidelines. In this work, we evaluate the inter-patient magnitude of individual ECG alterations during ischemia. The freely available STAFF III database provides 12-lead ECG recordings of patients before, during, and after elective percutaneous coronary intervention(PCI), where a coronary vessel is widened with a balloon inflation. We compute individual alterations of ST-interval and T-wave amplitudes w.r.t. QRS amplitude over time for each patient and lead. We demonstrate that determining relative ST-interval/T-wave amplitudes and deriving individual alterations over time is feasible in standard and non-standard ECG recordings. To demonstrate clinical relevance, we use the features for differentiating N=54 STAFF III patients with atherosclerotic plaque in either the right coronary artery (RCA) or left ascending artery (LAD). Results show significant differen
Surgical phase recognition (SPR) is a crucial element in the digital transformation of the modern operating theater. While SPR based on video sources is well-established, incorporation of interventional X-ray sequences has not yet been explored. This paper presents Pelphix, a first approach to SPR for X-ray-guided percutaneous pelvic fracture fixation, which models the procedure at four levels of granularity -- corridor, activity, view, and frame value -- simulating the pelvic fracture fixation workflow as a Markov process to provide fully annotated training data. Using added supervision from detection of bony corridors, tools, and anatomy, we learn image representations that are fed into a transformer model to regress surgical phases at the four granularity levels. Our approach demonstrates the feasibility of X-ray-based SPR, achieving an average accuracy of 93.8% on simulated sequences and 67.57% in cadaver across all granularity levels, with up to 88% accuracy for the target corridor in real data. This work constitutes the first step toward SPR for the X-ray domain, establishing an approach to categorizing phases in X-ray-guided surgery, simulating realistic image sequences to e
Background and Purpose: Percutaneous renal access in the context of percutaneous nephrolithotomy (PCNL) is a difficult technique, requiring rapid and precise access to a particular calix. We present a computerized system designed to improve percutaneous renal access by projecting the ultrasound puncture tract onto fluoroscopic images. Materials and Methods: The system consists of a computer and a localizer allowing spatial localization of the position of the various instruments. Without any human intervention, the ultrasound nephrostomy tract is superimposed in real time onto fluoroscopic images acquired in various views. Results: We tested our approach by laboratory experiments on a phantom. Also, after approval by our institution's Ethics Committee, we validated this technique in the operating room during PCNL in one patient. Conclusion: Our system is reliable, and the absence of image-processing procedures makes it robust. We have initiated a prospective study to validate this technique both for PCNL specialists and as a learning tool.
This paper introduces the principles of computer assisted percutaneous renal puncture, that would provide the surgeon with an accurate pre-operative 3D planning on CT images and, after a rigid registration with space-localized echographic data, would help him to perform the puncture through an intuitive 2D/3D interface. The whole development stage relied on both CT and US images of a healthy subject. We carried out millimetric registrations on real data, then guidance experiments on a kidney phantom showed encouraging results.
Background. Percutaneous coronary intervention(PCI) in stable coronary artery disease(CAD) is commonly triggered by abnormal myocardial perfusion imaging(MPI). However, due to the possibilities of multivessel disease and variability of coronary artery perfusion distribution, opportunity exists to better align anatomic stenosis with perfusion abnormalities to improve revascularization decisions. This study aims to develop a 3D multi-modality fusion approach to assist decision-making for PCI. Methods. Coronary arteries from fluoroscopic angiography(FA) were reconstructed into 3D artery anatomy. Left ventricular(LV) epicardial surface was extracted from SPECT. The 3D artery anatomy was non-rigidly fused with the LV epicardial surface. The accuracy of the 3D fusion was evaluated via both computer simulation and real patient data. For technical validation, simulated FA and MPI were integrated and then compared with the ground truth from a digital phantom. For clinical validation, FA and SPECT images were integrated and then compared with the ground truth from CT angiograms. Results. In the technical evaluation, the distance-based mismatch error between simulated fluoroscopy and phantom
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlapping ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection from a large number of randomized geometrical arrangements is presented. Two uncertainty parameters are introduced to account for tissue shrinking and tolerance of non-ablated tumour volume. For seven clinical renal T1a, T1b and T2a tumours, ablation plans were proposed by the software. All proposals are comparable to manual plans of an experienced physician with regard to the number of required ablation zones.
In this work, the Theory of Porous Media (TPM) is employed to model percutaneous vertebroplasty, a medical procedure in which acrylic cement is injected into cancellous vertebral bone. Previously, isothermal macroscale models have been derived to describe this material injection and the mechanical interactions which arise. However, the temperature of the injected cement is typically below the human body temperature, necessitating the extension of these models to the non-isothermal case. Following the modelling principles of the TPM and considering local thermal non-equilibrium conditions, our model introduces three energy balances as well as additional constitutive relations. If restricted to local thermal equilibrium conditions, our model equations are in agreement with other examples of TPM-based models. We observe that our model elicits physically reasonable behaviour in numerical simulations which employ parameter values and initial and boundary conditions relevant for our application. Noting that we neglect capillary effects, we claim our model to be thermodynamically consistent despite the employment of simplifying assumptions during its derivation, such as the Coleman and No
Ultrasound-guided percutaneous needle insertion is a standard procedure employed in both biopsy and ablation in clinical practices. However, due to the complex interaction between tissue and instrument, the needle may deviate from the in-plane view, resulting in a lack of close monitoring of the percutaneous needle. To address this challenge, we introduce a robot-assisted ultrasound (US) imaging system designed to seamlessly monitor the insertion process and autonomously restore the visibility of the inserted instrument when misalignment happens. To this end, the adversarial structure is presented to encourage the generation of segmentation masks that align consistently with the ground truth in high-order space. This study also systematically investigates the effects on segmentation performance by exploring various training loss functions and their combinations. When misalignment between the probe and the percutaneous needle is detected, the robot is triggered to perform transverse searching to optimize the positional and rotational adjustment to restore needle visibility. The experimental results on ex-vivo porcine samples demonstrate that the proposed method can precisely segment
Respiratory motion limits the accuracy and precision of abdominal percutaneous procedures. In this paper, respiratory motion is compensated robotically using motion estimation models. Additionally, a teleoperated insertion is performed using proximity-based haptic feedback to guide physicians during insertion, enabling a radiation-free remote insertion for the end-user. The study has been validated using a robotic liver phantom, and five insertions were performed. The resulting motion estimation errors were below 3 mm for all directions of motion, and the overall resulting 3D insertion errors were 2.60, 7.75, and 2.86 mm for the superior-inferior, lateral, and anterior-posterior directions of motion, respectively. The proposed approach is expected to minimize the chances of inaccurate treatment or diagnosis due to respiratory-induced motion and reduce radiation exposure.
Robotic-assisted percutaneous coronary intervention (PCI) holds considerable promise for elevating precision and safety in cardiovascular procedures. Nevertheless, current systems heavily depend on human operators, resulting in variability and the potential for human error. To tackle these challenges, Sim4EndoR, an innovative reinforcement learning (RL) based simulation environment, is first introduced to bolster task-level autonomy in PCI. This platform offers a comprehensive and risk-free environment for the development, evaluation, and refinement of potential autonomous systems, enhancing data collection efficiency and minimizing the need for costly hardware trials. A notable aspect of the groundbreaking Sim4EndoR is its reward function, which takes into account the anatomical constraints of the vascular environment, utilizing the geometric characteristics of vessels to steer the learning process. By seamlessly integrating advanced physical simulations with neural network-driven policy learning, Sim4EndoR fosters efficient sim-to-real translation, paving the way for safer, more consistent robotic interventions in clinical practice, ultimately improving patient outcomes.
Precise percutaneous needle detection is crucial for ultrasound (US)-guided interventions. However, inherent limitations such as speckles, needle-like artifacts, and low resolution make it challenging to robustly detect needles, especially when their visibility is reduced or imperceptible. To address this challenge, we propose VibNet, a learning-based framework designed to enhance the robustness and accuracy of needle detection in US images by leveraging periodic vibration applied externally to the needle shafts. VibNet integrates neural Short-Time Fourier Transform and Hough Transform modules to achieve successive sub-goals, including motion feature extraction in the spatiotemporal space, frequency feature aggregation, and needle detection in the Hough space. Due to the periodic subtle vibration, the features are more robust in the frequency domain than in the image intensity domain, making VibNet more effective than traditional intensity-based methods. To demonstrate the effectiveness of VibNet, we conducted experiments on distinct \textit{ex vivo} porcine and bovine tissue samples. The results obtained on porcine samples demonstrate that VibNet effectively detects needles even w
Ultrasound (US)-guided needle insertion is widely employed in percutaneous interventions. However, providing feedback on the needle tip position via US imaging presents challenges due to noise, artifacts, and the thin imaging plane of US, which degrades needle features and leads to intermittent tip visibility. In this paper, a Mamba-based US needle tracker MambaXCTrack utilizing structured state space models cross-correlation (SSMX-Corr) and implicit motion prompt is proposed, which is the first application of Mamba in US needle tracking. The SSMX-Corr enhances cross-correlation by long-range modeling and global searching of distant semantic features between template and search maps, benefiting the tracking under noise and artifacts by implicitly learning potential distant semantic cues. By combining with cross-map interleaved scan (CIS), local pixel-wise interaction with positional inductive bias can also be introduced to SSMX-Corr. The implicit low-level motion descriptor is proposed as a non-visual prompt to enhance tracking robustness, addressing the intermittent tip visibility problem. Extensive experiments on a dataset with motorized needle insertion in both phantom and tissu