Text-conditioned generative models for volumetric medical imaging provide semantic control but lack explicit anatomical guidance, often resulting in outputs that are spatially ambiguous or anatomically inconsistent. In contrast, structure-driven methods ensure strong anatomical consistency but typically assume access to ground-truth annotations, which are unavailable when the target image is to be synthesized. We propose a retrieval-augmented approach for Text-to-CT generation that integrates semantic and anatomical information under a realistic inference setting. Given a radiology report, our method retrieves a semantically related clinical case using a 3D vision-language encoder and leverages its associated anatomical annotation as a structural proxy. This proxy is injected into a text-conditioned latent diffusion model via a ControlNet branch, providing coarse anatomical guidance while maintaining semantic flexibility. Experiments on the CT-RATE dataset show that retrieval-augmented generation improves image fidelity and clinical consistency compared to text-only baselines, while additionally enabling explicit spatial controllability, a capability inherently absent in such appro
Large-scale text-to-image foundation models have achieved remarkable visual realism, yet generating human images with correct anatomical structures remains challenging. Existing approaches enforce anatomical constraints through part-specific modules or localized loss weighting during supervised fine-tuning on high-quality human photos, but such datasets are limited and often provide ambiguous optimization signals due to confounding factors such as lighting, pose, and background. Preference-based alignment offers an alternative, but standard Direct Preference Optimization (DPO) treats all pixels equally and therefore fails to exploit the localized nature of anatomical artifacts. To address this, we propose the framework of Alignment via Synthetic Anatomical Preference (ASAP), which constructs controlled preference pairs through a localized degradation mechanism applied to high-fidelity human images. This mechanism performs a controlled experiment on images by introducing explicit anatomical errors in targeted regions while preserving the remaining content. With this mechanism, we create the Human Anatomical Preference (HAP) dataset with over 10K curated pairs for effective anatomica
Accurately delineating tissues and reconstructing their chromophore compositions from Multispectral Optoacoustic Tomography (MSOT) images is a key challenge in optoacoustic imaging. The difficulty arises because light fluence distributions within tissue intrinsically depend on spectral optical properties, making the inverse problem inherently ill-posed. Currently, there is a lack of studies leveraging a priori probabilistic anatomical knowledge to guide tissue segmentation and infer chromophore composition. Moreover, most current studies address these two tasks sequentially, which can result in errors accumulating. through the process. To address these issues, we present Anatomical Priors for Reconstruction of Optoacoustic Tomography (APRECOT), a method that leverages probabilistic models of anatomical structures and tissue properties, to enable simultaneous segmentation of tissues and reconstruction of their bulk chromophore compositions. In this proof-of-concept using in-silico data, we show that incorporating probabilistic anatomical context strongly improves the accuracy of bulk chromophore concentration estimation compared to reference methods that do not use any anatomical co
Diffusion models have enabled remarkably high-quality medical image generation, yet it is challenging to enforce anatomical constraints in generated images. To this end, we propose a diffusion model-based method that supports anatomically-controllable medical image generation, by following a multi-class anatomical segmentation mask at each sampling step. We additionally introduce a random mask ablation training algorithm to enable conditioning on a selected combination of anatomical constraints while allowing flexibility in other anatomical areas. We compare our method ("SegGuidedDiff") to existing methods on breast MRI and abdominal/neck-to-pelvis CT datasets with a wide range of anatomical objects. Results show that our method reaches a new state-of-the-art in the faithfulness of generated images to input anatomical masks on both datasets, and is on par for general anatomical realism. Finally, our model also enjoys the extra benefit of being able to adjust the anatomical similarity of generated images to real images of choice through interpolation in its latent space. SegGuidedDiff has many applications, including cross-modality translation, and the generation of paired or counte
Panoramic radiograph (PR) is fundamentally used in routine dental care, but it inherently provides only a two-dimensional (2D) projection of complex three-dimensional (3D) craniofacial anatomy. Most existing learning-based methods attempt to computationally recover this 3D information by directly regressing native cone-beam computed tomography (CBCT) volumes from PR. However, this direct mapping requires the model to simultaneously learn common anatomical structures and patient-specific morphological variations. This entangled formulation makes the ill-posed 2D-to-3D inverse problem highly ambiguous, often producing over-smoothed reconstructions with blurred anatomical boundaries. To address this, we propose HyDAR-Pano3D, a two-stage framework that reformulates PR-to-CBCT reconstruction as a disentangled anatomical recovery problem. In Stage 1, a dual-encoder network integrates radiographic features with SAM-derived semantic priors to reconstruct an arch-normalized canonical volume. In Stage 2, an Anatomical Restoration Network predicts a prior-constrained structured deformation field to map this canonical volume back to the native space, restoring individual morphological variatio
Multi-modal Magnetic Resonance Imaging (MRI) is imperative for accurate brain tumor segmentation, offering indispensable complementary information. Nonetheless, the absence of modalities poses significant challenges in achieving precise segmentation. Recognizing the shared anatomical structures between mono-modal and multi-modal representations, it is noteworthy that mono-modal images typically exhibit limited features in specific regions and tissues. In response to this, we present Anatomical Consistency Distillation and Inconsistency Synthesis (ACDIS), a novel framework designed to transfer anatomical structures from multi-modal to mono-modal representations and synthesize modality-specific features. ACDIS consists of two main components: Anatomical Consistency Distillation (ACD) and Modality Feature Synthesis Block (MFSB). ACD incorporates the Anatomical Feature Enhancement Block (AFEB), meticulously mining anatomical information. Simultaneously, Anatomical Consistency ConsTraints (ACCT) are employed to facilitate the consistent knowledge transfer, i.e., the richness of information and the similarity in anatomical structure, ensuring precise alignment of structural features acro
This work addresses the computational problem of generating reproducible projection-space observations from heterogeneous anatomical scenes whose components may undergo independent spatial transformations. We propose a transformation-driven framework for synthetic projection imaging from multimodal anatomical data and demonstrate it on mandibular-motion scenarios. In contrast to conventional Digitally Reconstructed Radiograph (DRR) approaches primarily designed for registration, projection realism, or rendering efficiency, the proposed formulation treats projection imaging as an observation process operating on an explicitly represented anatomical scene. Independently transformable volumetric and surface-based anatomical objects are embedded within a shared scene representation and propagated directly into projection space through explicit transformations. Projection geometry, acquisition modelling, material interpretation, and image presentation remain explicitly separated, enabling controlled exploration of methodological assumptions while preserving reproducibility and direct comparability between generated projections. Particular emphasis is placed on transformation-driven anat
Video transformers have recently demonstrated strong potential for echocardiogram (echo) analysis, leveraging self-supervised pre-training and flexible adaptation across diverse tasks. However, like other models operating on videos, they are prone to learning spurious correlations from non-diagnostic regions such as image backgrounds. To overcome this limitation, we propose the Video Anatomically Constrained Transformer (ViACT), a novel framework that integrates anatomical priors directly into the transformer architecture. ViACT represents a deforming anatomical structure as a point set and encodes both its spatial geometry and corresponding image patches into transformer tokens. During pre-training, ViACT follows a masked autoencoding strategy that masks and reconstructs only anatomical patches, enforcing that representation learning is focused on the anatomical region. The pre-trained model can then be fine-tuned for tasks localized to this region. In this work we focus on the myocardium, demonstrating the framework on echo analysis tasks such as left ventricular ejection fraction (EF) regression and cardiac amyloidosis (CA) detection. The anatomical constraint focuses transforme
Deep-learning-based denoising methods have significantly improved Low-Dose CT (LDCT) image quality. However, existing models often over-smooth important anatomical details due to their purely data-driven attention mechanisms. To address this challenge, we propose a novel LDCT denoising framework, BioAtt. The key innovation lies in attending anatomical prior distributions extracted from the pretrained vision-language model BiomedCLIP. These priors guide the denoising model to focus on anatomically relevant regions to suppress noise while preserving clinically relevant structures. We highlight three main contributions: BioAtt outperforms baseline and attention-based models in SSIM, PSNR, and RMSE across multiple anatomical regions. The framework introduces a new architectural paradigm by embedding anatomic priors directly into spatial attention. Finally, BioAtt attention maps provide visual confirmation that the improvements stem from anatomical guidance rather than increased model complexity.
Accurate delineation of anatomical structures in volumetric CT scans is crucial for diagnosis and treatment planning. While AI has advanced automated segmentation, current approaches typically target individual structures, creating a fragmented landscape of incompatible models with varying performance and disparate evaluation protocols. Foundational segmentation models address these limitations by providing a holistic anatomical view through a single model. Yet, robust clinical deployment demands comprehensive training data, which is lacking in existing whole-body approaches, both in terms of data heterogeneity and, more importantly, anatomical coverage. In this work, rather than pursuing incremental optimizations in model architecture, we present CADS, an open-source framework that prioritizes the systematic integration, standardization, and labeling of heterogeneous data sources for whole-body CT segmentation. At its core is a large-scale dataset of 22,022 CT volumes with complete annotations for 167 anatomical structures, representing a significant advancement in both scale and coverage, with 18 times more scans than existing collections and 60% more distinct anatomical targets.
Anatomical mesh segmentation requires models that operate directly on irregular surface geometry while remaining robust to arbitrary patient pose and mesh resolution variation. Existing task-specific mesh and point-cloud methods are not equivariant, and can degrade sharply under test-time perturbation, for example dropping by 25-26 IoU points on intraoral scan segmentation at $40^\circ$ tilt. We present EAMS, an Equivariant Anatomical Mesh Segmentor built on Equivariant Mesh Neural Networks (EMNN), and evaluate it across four clinically distinct tasks spanning edge-, vertex-, and face-level supervision. We combine intrinsic mesh descriptors with anatomy-aware priors, including PCA-derived frames for dental arches and liver surfaces, and augment message passing to provide lightweight global context. Across intracranial aneurysm and intraoral segmentation, EAMS variants are competitive with specialized baselines on unperturbed inputs while remaining stable under geometric perturbations, and on liver surfaces they expose a favorable trade-off between canonical-pose accuracy and rotation robustness. These results show that a lightweight ($<2$M parameters) equivariant framework can d
Generative modeling of anatomical structures plays a crucial role in virtual imaging trials, which allow researchers to perform studies without the costs and constraints inherent to in vivo and phantom studies. For clinical relevance, generative models should allow targeted control to simulate specific patient populations rather than relying on purely random sampling. In this work, we propose a steerable generative model based on implicit neural representations. Implicit neural representations naturally support topology changes, making them well-suited for anatomical structures with varying topology, such as the thyroid. Our model learns a disentangled latent representation, enabling fine-grained control over shape variations. Evaluation includes reconstruction accuracy and anatomical plausibility. Our results demonstrate that the proposed model achieves high-quality shape generation while enabling targeted anatomical modifications.
Anatomical understanding through deep learning is critical for automatic report generation, intra-operative navigation, and organ localization in medical imaging; however, its progress is constrained by the scarcity of expert-labeled data. A promising remedy is to leverage an annotated reference image to guide the interpretation of an unlabeled target. Although recent vision-language models (VLMs) exhibit non-trivial visual reasoning, their reference-based understanding and fine-grained localization remain limited. We introduce RAU, a framework for reference-based anatomical understanding with VLMs. We first show that a VLM learns to identify anatomical regions through relative spatial reasoning between reference and target images, trained on a moderately sized dataset. We validate this capability through visual question answering (VQA) and bounding box prediction. Next, we demonstrate that the VLM-derived spatial cues can be seamlessly integrated with the fine-grained segmentation capability of SAM2, enabling localization and pixel-level segmentation of small anatomical regions, such as vessel segments. Across two in-distribution and two out-of-distribution datasets, RAU consisten
3D brain MRI studies often examine subtle morphometric differences between cohorts that are hard to detect visually. Given the high cost of MRI acquisition, these studies could greatly benefit from image syntheses, particularly counterfactual image generation, as seen in other domains, such as computer vision. However, counterfactual models struggle to produce anatomically plausible MRIs due to the lack of explicit inductive biases to preserve fine-grained anatomical details. This shortcoming arises from the training of the models aiming to optimize for the overall appearance of the images (e.g., via cross-entropy) rather than preserving subtle, yet medically relevant, local variations across subjects. To preserve subtle variations, we propose to explicitly integrate anatomical constraints on a voxel-level as prior into a generative diffusion framework. Called Probabilistic Causal Graph Model (PCGM), the approach captures anatomical constraints via a probabilistic graph module and translates those constraints into spatial binary masks of regions where subtle variations occur. The masks (encoded by a 3D extension of ControlNet) constrain a novel counterfactual denoising UNet, whose
3D medical image generation is essential for data augmentation and patient privacy, calling for reliable and efficient models suited for clinical practice. However, current methods suffer from limited anatomical fidelity, restricted axial length, and substantial computational cost, placing them beyond reach for regions with limited resources and infrastructure. We introduce TRACE, a framework that generates 3D medical images with spatiotemporal alignment using a 2D multimodal-conditioned diffusion approach. TRACE models sequential 2D slices as video frame pairs, combining segmentation priors and radiology reports for anatomical alignment, incorporating optical flow to sustain temporal coherence. During inference, an overlapping-frame strategy links frame pairs into a flexible length sequence, reconstructed into a spatiotemporally and anatomically aligned 3D volume. Experimental results demonstrate that TRACE effectively balances computational efficiency with preserving anatomical fidelity and spatiotemporal consistency. Code is available at: https://github.com/VinyehShaw/TRACE.
Medical Phrase Grounding (MPG) maps radiological findings described in medical reports to specific regions in medical images. The primary obstacle hindering progress in MPG is the scarcity of annotated data available for training and validation. We propose anatomical grounding as an in-domain pre-training task that aligns anatomical terms with corresponding regions in medical images, leveraging large-scale datasets such as Chest ImaGenome. Our empirical evaluation on MS-CXR demonstrates that anatomical grounding pre-training significantly improves performance in both a zero-shot learning and fine-tuning setting, outperforming state-of-the-art MPG models. Our fine-tuned model achieved state-of-the-art performance on MS-CXR with an mIoU of 61.2, demonstrating the effectiveness of anatomical grounding pre-training for MPG.
Progress in anatomical 3D shape classification is limited by the complexity of mesh data and the lack of standardized benchmarks, highlighting the need for robust learning methods and reproducible evaluation. We introduce two key steps toward clinically and benchmark-ready anatomical shape classification via self-supervised graph autoencoding. We propose Precomputed Structural Pooling (PSPooling), a non-learnable mesh pooling operator designed for efficient and structure-preserving graph coarsening in 3D anatomical shape analysis. PSPooling precomputes node correspondence sets based on geometric proximity, enabling parallelizable and reversible pooling and unpooling operations with guaranteed support structure. This design avoids the sparsity and reconstruction issues of selection-based methods and the sequential overhead of edge contraction approaches, making it particularly suitable for high-resolution medical meshes. To demonstrate its effectiveness, we integrate PSPooling into a self-supervised graph autoencoder that learns anatomy-aware representations from unlabeled surface meshes. We evaluate the downstream benefits on MedShapeNet19, a new curated benchmark dataset we derive
Cardiac amyloidosis (CA) is a rare cardiomyopathy, with typical abnormalities in clinical measurements from echocardiograms such as reduced global longitudinal strain of the myocardium. An alternative approach for detecting CA is via neural networks, using video classification models such as convolutional neural networks. These models process entire video clips, but provide no assurance that classification is based on clinically relevant features known to be associated with CA. An alternative paradigm for disease classification is to apply models to quantitative features such as strain, ensuring that the classification relates to clinically relevant features. Drawing inspiration from this approach, we explicitly constrain a transformer model to the anatomical region where many known CA abnormalities occur -- the myocardium, which we embed as a set of deforming points and corresponding sampled image patches into input tokens. We show that our anatomical constraint can also be applied to the popular self-supervised learning masked autoencoder pre-training, where we propose to mask and reconstruct only anatomical patches. We show that by constraining both the transformer and pre-train
We propose a self-supervised model producing 3D anatomical positional embeddings (APE) of individual medical image voxels. APE encodes voxels' anatomical closeness, i.e., voxels of the same organ or nearby organs always have closer positional embeddings than the voxels of more distant body parts. In contrast to the existing models of anatomical positional embeddings, our method is able to efficiently produce a map of voxel-wise embeddings for a whole volumetric input image, which makes it an optimal choice for different downstream applications. We train our APE model on 8400 publicly available CT images of abdomen and chest regions. We demonstrate its superior performance compared with the existing models on anatomical landmark retrieval and weakly-supervised few-shot localization of 13 abdominal organs. As a practical application, we show how to cheaply train APE to crop raw CT images to different anatomical regions of interest with 0.99 recall, while reducing the image volume by 10-100 times. The code and the pre-trained APE model are available at https://github.com/mishgon/ape .
Particle-based shape modeling (PSM) is a family of approaches that automatically quantifies shape variability across anatomical cohorts by positioning particles (pseudo landmarks) on shape surfaces in a consistent configuration. Recent advances incorporate implicit radial basis function representations as self-supervised signals to better capture the complex geometric properties of anatomical structures. However, these methods still lack self-adaptivity -- that is, the ability to automatically adjust particle configurations to local geometric features of each surface, which is essential for accurately representing complex anatomical variability. This paper introduces two mechanisms to increase surface adaptivity while maintaining consistent particle configurations: (1) a novel neighborhood correspondence loss to enable high adaptivity and (2) a geodesic correspondence algorithm that regularizes optimization to enforce geodesic neighborhood consistency. We evaluate the efficacy and scalability of our approach on challenging datasets, providing a detailed analysis of the adaptivity-correspondence trade-off and benchmarking against existing methods on surface representation accuracy a