Photoplethysmography (PPG) plays a crucial role in continuous cardiovascular health monitoring as a non-invasive and cost-effective modality. However, PPG signals are susceptible to motion artifacts and noise, making accurate estimation of vital signs such as arterial blood pressure (ABP) challenging. Existing estimation methods are often restricted to a single-task or environment, limiting their generalizability across diverse PPG decoding scenarios. Moreover, recent general-purpose approaches typically rely on predictions over multi-second intervals, discarding the morphological characteristics of vital signs. To address these challenges, we propose PENGUIN, a generative flow-matching framework that extends deep state space models, enabling fine-grained conditioning on PPG for reconstructing multiple vital signs as continuous waveforms. We evaluate PENGUIN using six real-world PPG datasets across three distinct vital sign reconstruction tasks (electrocardiogram reconstruction, respiratory monitoring, and ABP monitoring). Our method consistently outperformed both task-specific and general-purpose baselines, demonstrating PENGUIN as a general framework for robust vital sign reconst
We consider the problem of assessing a group of nodes in a network. Our focus is on vitality indices -- a natural class of centrality measures that evaluate the importance of a node by examining the impact of its removal on the network. We conduct a comprehensive analysis of group vitality indices. Specifically, we show that every vitality index admits a unique extension to groups, which can be defined using a group variant of the Shapley value recently proposed in the literature. We also provide an axiomatization of the entire class, along with two specific group vitality indices that satisfy additional normalization conditions. Furthermore, we study the computational properties of all vitality indices, as well as Group Attachment Centrality.
In this work, we introduce an innovative approach to estimate the vital signs of multiple human subjects simultaneously in a non-contact way using a Frequency Modulated Continuous Wave (FMCW) radar-based system. Traditional vital sign monitoring methods often face significant limitations, including subject discomfort with wearable devices, challenges in calibration, and the risk of infection transmission through contact measurement devices. To address these issues, this research is motivated by the need for versatile, non-contact vital monitoring solutions applicable in various critical scenarios. This work also explores the challenges of extending this capability to an arbitrary number of subjects, including hardware and theoretical limitations. Supported by rigorous experimental results and discussions, the paper illustrates the system's potential to redefine vital sign monitoring. An FPGA-based implementation is also presented as proof of concept for a hardware-based and portable solution, improving upon previous works by offering 2.7x faster execution and 18.4% less Look-Up Table (LUT) utilization, as well as providing over 7400x acceleration compared to its software counterpar
The integration of vital signs in healthcare has witnessed a steady rise, promising health professionals to assist in their daily tasks to improve patient treatment. In life-threatening situations, like rescue operations, crucial decisions need to be made in the shortest possible amount of time to ensure that excellent treatment is provided during life-saving measurements. The integration of vital signs in the treatment holds the potential to improve time utilization for rescuers in such critical situations. They furthermore serve to support health professionals during the treatment with useful information and suggestions. To achieve such a goal, the KIRETT project serves to provide treatment recommendations and situation detection, combined on a wrist-worn wearable for rescue operations.This paper aims to present the significant role of vital signs in the improvement of decision-making during rescue operations and show their impact on health professionals and patients in need.
Despite the remarkable progress of deep-learning methods generating a target vital sign waveform from a source vital sign waveform, most existing models are designed exclusively for a specific source-to-target pair. This requires distinct model architectures, optimization procedures, and pre-processing pipelines, resulting in multiple models that hinder usability in clinical settings. To address this limitation, we propose the Multi-Directional Vital-Sign Converter (MD-ViSCo), a unified framework capable of generating any target waveform such as electrocardiogram (ECG), photoplethysmogram (PPG), or arterial blood pressure (ABP) from any single input waveform with a single model. MD-ViSCo employs a shallow 1-Dimensional U-Net integrated with a Swin Transformer that leverages Adaptive Instance Normalization (AdaIN) to capture distinct waveform styles. To evaluate the efficacy of MD-ViSCo, we conduct multi-directional waveform generation on two publicly available datasets. Our framework surpasses state-of-the-art baselines (NabNet & PPG2ABP) on average across all waveform types, lowering Mean absolute error (MAE) by 8.8% and improving Pearson correlation (PC) by 4.9% over two data
Vital sign monitoring plays a critical role in healthcare and well-being, as parameters such as respiration and heart rate offer valuable insights into an individual's physiological state. While wearable devices allow for continuous measurement, their use in settings like in-home elderly care is often hindered by discomfort or user noncompliance. As a result, contactless solutions based on radar sensing have garnered increasing attention. This is due to their unobtrusive design and preservation of privacy advantages compared to camera-based systems. However, a single radar perspective can fail to capture breathing-induced chest movements reliably, particularly when the subject's orientation is unfavorable. To address this limitation, we integrate a reconfigurable intelligent surface (RIS) that provides an additional sensing path, thereby enhancing the robustness of respiratory monitoring. We present a novel model for multi-path vital sign sensing that leverages both the direct radar path and an RIS-reflected path. We further discuss the potential benefits and improved performance our approach offers in continuous, privacy-preserving vital sign monitoring.
Let G be a directed weighted graph (DiGraph) on n vertices and m edges with source s and sink t. An edge in G is vital if its removal reduces the capacity of (s,t)-mincut. Since the seminal work of Ford and Fulkerson, a long line of work has been done on computing the most vital edge and all vital edges of G. Unfortunately, after 60 years, the existing results are for undirected or unweighted graphs. We present the following result for DiGraph, which solves an open problem stated by Ausiello et al. 1. There is an algorithm that computes all vital edges as well as the most vital edge of G using O(n) maxflow computations. Vital edges play a crucial role in the design of Sensitivity Oracle (SO) for (s,t)-mincut. For directed graphs, the only existing SO is for unweighted graphs by Picard and Queyranne. We present the first and optimal SO for DiGraph. 2. (a) There is an O(n) space SO that can report in O(1) time the capacity of (s,t)-mincut and (b) an O($n^2$) space SO that can report an (s,t)-mincut in O(n) time after failure/insertion of an edge. For unweighted graphs, Picard and Queyranne designed an O(m) space DAG that stores and characterizes all mincuts for all vital edges. Conve
Radar-based vital sign monitoring (VSM) systems have become valuable for non-contact health monitoring by detecting physiological activities, such as respiration and heartbeat, remotely. However, the conventional phased array used in VSM is vulnerable to privacy breaches, as an eavesdropper can extract sensitive vital sign information by analyzing the reflected radar signals. In this paper, we propose a novel approach to protect privacy in radar-based VSM by modifying the radar transmitter hardware, specifically by strategically selecting the transmit antennas from the available antennas in the transmit array. By dynamically selecting which antennas connect or disconnect to the radio frequency chain, the transmitter introduces additional phase noise to the radar echoes, generating false frequencies in the power spectrum of the extracted phases at the eavesdropper's receiver. The antenna activation pattern is designed to maximize the variance of the phases introduced by antenna selection, which effectively makes the false frequencies dominate the spectrum, obscuring the actual vital sign frequencies. Meanwhile, the authorized receiver, having knowledge of the antenna selection patte
Real-time vital sign monitoring is gaining immense significance not only in the medical field but also in personal health management. Facing the needs of different application scenarios of the smart and healthy city in the future, the low-cost, large-scale, scalable, and distributed vital sign monitoring system is of great significance. In this work, a seamlessly integrated contact and contactless vital sign monitoring system, which can simultaneously implement respiration and heartbeat monitoring, is proposed. In contact vital sign monitoring, the chest wall movement due to respiration and heartbeat is translated into changes in the optical output intensity of a fiber Bragg grating (FBG). The FBG is also an important part of radar signal generation for contactless vital sign monitoring, in which the chest wall movement is translated into phase changes of the radar de-chirped signal. By analyzing the intensity of the FBG output and phase of the radar de-chirped signal, real-time respiration and heartbeat monitoring are realized. In addition, due to the distributed structure of the system and its good integration with the wavelength-division multiplexing optical network, it can be m
Accurate phase demodulation is critical for vital sign detection using millimeter-wave radar. However, in complex environments, time-varying DC offsets and phase imbalances can severely degrade demodulation performance. To address this, we propose a novel DC offset calibration method alongside a Hilbert and Differential Cross-Multiply (HADCM) demodulation algorithm. The approach estimates time-varying DC offsets from neighboring signal peaks and valleys, then employs both differential forms and Hilbert transforms of the I/Q channel signals to extract vital sign information. Simulation and experimental results demonstrate that the proposed method maintains robust performance under low signal-to-noise ratios. Compared to existing demodulation techniques, it offers more accurate signal recovery in challenging scenarios and effectively suppresses noise interference.
This paper investigates the application of millimeter-wave (mmWave) radar for the estimation of human vital signs. Aiming to obtain more accurate frequency estimation for periodic signals of respiration and heartbeat, we propose the harmonic MUSIC (HMUSIC) algorithm to consider harmonic components for frequency estimation of vital sign signals. In the experiments, we tested different subjects' vital signs. Experimental results demonstrate that the 89-th percentile errors in respiration rate and the 88-th percentile errors in heartbeat rate are less than 3 respirations per minute and 5 beats per minute.
Neural networks are widely adopted to solve complex and challenging tasks. Especially in high-stakes decision-making, understanding their reasoning process is crucial, yet proves challenging for modern deep networks. Feature visualization (FV) is a powerful tool to decode what information neurons are responding to and hence to better understand the reasoning behind such networks. In particular, in FV we generate human-understandable images that reflect the information detected by neurons of interest. However, current methods often yield unrecognizable visualizations, exhibiting repetitive patterns and visual artifacts that are hard to understand for a human. To address these problems, we propose to guide FV through statistics of real image features combined with measures of relevant network flow to generate prototypical images. Our approach yields human-understandable visualizations that both qualitatively and quantitatively improve over state-of-the-art FVs across various architectures. As such, it can be used to decode which information the network uses, complementing mechanistic circuits that identify where it is encoded. Code is available at: https://github.com/adagorgun/VITAL
Detecting and predicting septic shock early is crucial for the best possible outcome for patients. Accurately forecasting the vital signs of patients with sepsis provides valuable insights to clinicians for timely interventions, such as administering stabilizing drugs or optimizing infusion strategies. Our research examines N-BEATS, an interpretable deep-learning forecasting model that can forecast 3 hours of vital signs for sepsis patients in intensive care units (ICUs). In this work, we use the N-BEATS interpretable configuration to forecast the vital sign trends and compare them with the actual trend to understand better the patient's changing condition and the effects of infused drugs on their vital signs. We evaluate our approach using the publicly available eICU Collaborative Research Database dataset and rigorously evaluate the vital sign forecasts using out-of-sample evaluation criteria. We present the performance of our model using error metrics, including mean squared error (MSE), mean average percentage error (MAPE), and dynamic time warping (DTW), where the best scores achieved are 18.52e-4, 7.60, and 17.63e-3, respectively. We analyze the samples where the forecasted t
This report introduces VitalLens, an app that estimates vital signs such as heart rate and respiration rate from selfie video in real time. VitalLens uses a computer vision model trained on a diverse dataset of video and physiological sensor data. We benchmark performance on several diverse datasets, including VV-Medium, which consists of 289 unique participants. VitalLens outperforms several existing methods including POS and MTTS-CAN on all datasets while maintaining a fast inference speed. On VV-Medium, VitalLens achieves mean absolute errors of 0.71 bpm for heart rate estimation, and 0.76 bpm for respiratory rate estimation.
Wireless techniques for monitoring human vital signs, such as heart and breathing rates, offer a promising solution in the context of joint communication and sensing (JCAS) with applications in medicine, sports, safety, security, and even the military. This paper reports experimental results obtained at the Fraunhofer Institute for Integrated Circuits in Ilmenau, demonstrating the effectiveness of an indoor orthogonal frequency-division multiplexing (OFDM) JCAS system for detecting human heart and breathing rates. The system operated in a bistatic configuration at an FR2 frequency of 26.5 GHz with a variable bandwidth of up to 1 GHz. Measurements were taken under various scenarios, including a subject lying down, sitting, or walking, in both line-of-sight and non-line-of-sight conditions, and with one or two subjects present simultaneously. The results indicate that while vital sign detection is generally feasible, its effectiveness is influenced by several factors, such as the subjects clothing, activity, as well as the distance and angle relative to the sensing system. In addition, no significant influence of bandwidth was detected since the vital signs information is encoded in
Non-contact vital sign monitoring has many advantages over conventional methods in being comfortable, unobtrusive and without any risk of spreading infection. The use of millimeter-wave (mmWave) radars is one of the most promising approaches that enable contact-less monitoring of vital signs. Novel low-power implementations of this technology promise to enable vital sign sensing in embedded, battery-operated devices. The nature of these new low-power sensors exacerbates the challenges of accurate and robust vital sign monitoring and especially the problem of heart-rate tracking. This work focuses on the investigation and characterization of three Frequency Modulated Continuous Wave (FMCW) low-power radars with different carrier frequencies of 24 GHz, 60 GHz and 120 GHz. The evaluation platforms were first tested on phantom models that emulated human bodies to accurately evaluate the baseline noise, error in range estimation, and error in displacement estimation. Additionally, the systems were also used to collect data from three human subjects to gauge the feasibility of identifying heartbeat peaks and breathing peaks with simple and lightweight algorithms that could potentially ru
Sepsis is a leading cause of mortality in intensive care units (ICUs), representing a substantial medical challenge. The complexity of analyzing diverse vital signs to predict sepsis further aggravates this issue. While deep learning techniques have been advanced for early sepsis prediction, their 'black-box' nature obscures the internal logic, impairing interpretability in critical settings like ICUs. This paper introduces a framework that combines a deep learning model with an attention mechanism that highlights the critical time steps in the forecasting process, thus improving model interpretability and supporting clinical decision-making. We show that the attention mechanism could be adapted to various black box time series forecasting models such as N-HiTS and N-BEATS. Our method preserves the accuracy of conventional deep learning models while enhancing interpretability through attention-weight-generated heatmaps. We evaluated our model on the eICU-CRD dataset, focusing on forecasting vital signs for sepsis patients. We assessed its performance using mean squared error (MSE) and dynamic time warping (DTW) metrics. We explored the attention maps of N-HiTS and N-BEATS, examinin
Contact-free vital sign monitoring, which uses wireless signals for recognizing human vital signs (i.e, breath and heartbeat), is an attractive solution to health and security. However, the subject's body movement and the change in actual environments can result in inaccurate frequency estimation of heartbeat and respiratory. In this paper, we propose a robust mmWave radar and camera fusion system for monitoring vital signs, which can perform consistently well in dynamic scenarios, e.g., when some people move around the subject to be tracked, or a subject waves his/her arms and marches on the spot. Three major processing modules are developed in the system, to enable robust sensing. Firstly, we utilize a camera to assist a mmWave radar to accurately localize the subjects of interest. Secondly, we exploit the calculated subject position to form transmitting and receiving beamformers, which can improve the reflected power from the targets and weaken the impact of dynamic interference. Thirdly, we propose a weighted multi-channel Variational Mode Decomposition (WMC-VMD) algorithm to separate the weak vital sign signals from the dynamic ones due to subject's body movement. Experimental
This work is on vision-based planning strategies for legged robots that separate locomotion planning into foothold selection and pose adaptation. Current pose adaptation strategies optimize the robot's body pose relative to given footholds. If these footholds are not reached, the robot may end up in a state with no reachable safe footholds. Therefore, we present a Vision-Based Terrain-Aware Locomotion (ViTAL) strategy that consists of novel pose adaptation and foothold selection algorithms. ViTAL introduces a different paradigm in pose adaptation that does not optimize the body pose relative to given footholds, but the body pose that maximizes the chances of the legs in reaching safe footholds. ViTAL plans footholds and poses based on skills that characterize the robot's capabilities and its terrain-awareness. We use the 90 kg HyQ and 140 kg HyQReal quadruped robots to validate ViTAL, and show that they are able to climb various obstacles including stairs, gaps, and rough terrains at different speeds and gaits. We compare ViTAL with a baseline strategy that selects the robot pose based on given selected footholds, and show that ViTAL outperforms the baseline.
Sepsis and septic shock are a critical medical condition affecting millions globally, with a substantial mortality rate. This paper uses state-of-the-art deep learning (DL) architectures to introduce a multi-step forecasting system to predict vital signs indicative of septic shock progression in Intensive Care Units (ICUs). Our approach utilizes a short window of historical vital sign data to forecast future physiological conditions. We introduce a DL-based vital sign forecasting system that predicts up to 3 hours of future vital signs from 6 hours of past data. We further adopt the DILATE loss function to capture better the shape and temporal dynamics of vital signs, which are critical for clinical decision-making. We compare three DL models, N-BEATS, N-HiTS, and Temporal Fusion Transformer (TFT), using the publicly available eICU Collaborative Research Database (eICU-CRD), highlighting their forecasting capabilities in a critical care setting. We evaluate the performance of our models using mean squared error (MSE) and dynamic time warping (DTW) metrics. Our findings show that while TFT excels in capturing overall trends, N-HiTS is superior in retaining short-term fluctuations wi