Dielectric cylindrical waveguides are widely used for confining and guiding of electromagnetic waves in relatively wide range of frequencies. They have found numerous technological and scientific applications in telecommunications, medicine, material science, photonics and quantum optics. The electromagnetic field Green function is the central object in investigations of different types of radiation processes in those structures. In this paper, we review and further develop the recurrence procedure for evaluating the electromagnetic field Green function in a medium made of any number of homogeneous cylindrical layers. The general results are specified for a cylindrical waveguide immersed in a homogeneous medium. Expressions are provided for all the components of the Green tensor in both regions inside and outside the cylinder. As an application of the results for the Green function, we consider the radiation of a charged particle rotating around a dielectric cylinder. The intensities for all types of radiation processes are discussed. They include the synchrotron-Cherenkov radiation at large distances from the cylinder and the radiation on guided and surface polaritonic modes confi
The theory of radiation of twisted photons in elliptical multifrequency undulators is developed. It is shown that helical multifrequency undulators can be employed as a bright and versatile source of photons in the states that are superpositions of the modes with definite projection of total angular momentum (TAM), amplitude, and relative phase. All these parameters of the state are readily controlled by the undulator design. The explicit expression for the amplitude of radiation of a twisted photon from a charged particle in the multifrequency undulator is derived. The energy spectrum of radiation and the selection rules for the TAM projection of radiated photons are described. The symmetry properties of the spectrum with respect to the TAM projection are established. The interpretation to the energy spectrum and to the selection rules is given in terms of virtual photons mediating between the charged particle and the undulator. The results obtained are also applicable to radiation of twisted photons produced by ultrarelativistic charged particles moving in plane multifrequency electromagnetic waves.
We explore asymptotically locally anti-de Sitter spacetimes exhibiting gravitational radiative behavior, employing null gauges that allow for a well-defined flat limit. The radiative content in the bulk is captured by the boundary Cotton and stress tensor, which we collect into a radiative vector. We reinterpret this vector holographically in terms of fluid variables in the dual boundary theory. For algebraically special solutions, we uncover a close connection between bulk radiation and dissipative corrections in the boundary stress tensor, demonstrating a direct link between radiation and entropy production in the boundary fluid. This reveals a rich interplay between radiative dynamics in the bulk and out-of-equilibrium conformal physics at the boundary. We then investigate the flat limit of this correspondence in the context of flat-space holography. In this setting, we construct a Carrollian analogue of the radiative vector and introduce Celestial observables, such as energy detectors, which emerge naturally from the bulk's radiative structure. Our analysis shows that bulk radiation sources the Carrollian viscous stress tensor and heat current, which encodes the Bondi news in t
A recent proposal reinterprets the eikonal as the scattering generator, which computes scattering observables through an action as a symmetry generator. The aim of this study is to incorporate dissipative effects from radiation into this framework, where the eikonal is generalised to the radiation eikonal by including mediator field degrees of freedom. The proposed generalisation is tested through several post-Minkowskian scattering observables; scattering waveform, radiated momentum, and (time asymmetric) radiation loss in the impulse.
We investigate the electromagnetic radiation from a chain of relativistic charged particles uniformly rotating along equatorial orbit around a dielectric ball. For weak absorption of radiation in the ball material, at certain rotation frequency the radiation intensity becomes significantly higher than the corresponding value for a chain of charges rotating in free space or in a transparent medium with the same dielectric constant as that for the ball material. In the case of an equidistant distribution of charged particles along the orbit we determine the values of parameters of the problem for which the charges in the chain emit coherently. It is shown that the radiation intensity on a given harmonic increases in proportion to the square of the number of emitting charges. We also show that the relative shifts in the particles locations up to 10\% do not destroy the coherence properties of the radiation. It is demonstrated that the coherence effects may also dominate in the radiation intensity for chains with non-equidistant distributions of particles. The numerical results obtained for different dielectric balls have revealed the emitted radiation to be in the GHz/THz frequency ra
We extend the angular power density formulae for spontaneous radiation emission from planar undulators to include finite emittance and angular misalignment of the electron beam. Then we calculate and compare power densities estimated from integral approach with Gaussian beam distribution and summation approach with the macro-particle allocation covering the particle beam phase space. After showing that both approaches converge to each other, we apply the macro-particle approach to study power absorbed and transmitted by various apertures at the front end of the 9-ID beamline at the National Synchrotron Light Source-II. Our analysis indicate that the electron beam misalignment could lead to unwarranted power deposition at tighter apertures that would have been otherwise difficult to account in the aperture design/choice process using the geometric ray-tracing approach.
The Geiger photodiodes, or single photon avalanche photodiodes, for a radiation tolerant solid-state photomultiplier (SSPM) are being designed using Aluminum Gallium Arsenide (AlGaAs) and are less than 1 micrometer thick. Studies on the changes in dark current compared to silicon from thermal neutron damage were conducted demonstrating that the design concept is feasible, as the device sensitivity to incident radiation is low relative to silicon devices. To achieve the required high fields for Geiger mode operation within a thin device, a triple mesa structure was developed, and simulations show a favorable field profile that constrains the highest electric fields to the middle of the device and keeps the field strength at all corners and surfaces 3-6x lower than the field in the center at breakdown.
A central component of the European Spallation Source is the high-power proton accelerator. The accelerator aims in the future to provide 2 GeV protons to a rotating tungsten target for the production of neutrons at 5 MW of average beam power for neutron scattering studies. Extensive shielding surrounds the accelerator, in order to provide sufficient safety for the public and workers against radiation produced along it's length. This largely comprises several meters of soil, called the berm, and concrete structures located around the accelerator tunnel. However, due to the need for access to the accelerator, during maintenance and connections for other utilities, the shielding contains a number of penetrations which leads to weaknesses in localized areas. For these reasons, shielding design of such a facility must take care to address issues related to both the deep-penetration of the radiation through thick shields, while at the same time accounting for the streaming nature of the radiation through ducts and chicanes. In addition, radiation produced from activated components of the accelerator also poses risks for workers and public. For example, activated magnets will need mainte
Artificial intelligence (AI) is about to touch every aspect of radiotherapy from consultation, treatment planning, quality assurance, therapy delivery, to outcomes modeling. There is an urgent need to train radiation oncologists and medical physicists in data science to help shepherd AI solutions into clinical practice. Poorly trained personnel may do more harm than good when attempting to apply rapidly developing and complex technologies. As the amount of AI research expands in our field, the radiation oncology community needs to discuss how to educate future generations in this area. The National Cancer Institute (NCI) Workshop on AI in Radiation Oncology (Shady Grove, MD, April 4-5, 2019) was the first (https://dctd.cancer.gov/NewsEvents/20190523_ai_in_radiation_oncology.htm) of two data science workshops in radiation oncology hosted by the NCI in 2019. During this workshop, the Training and Education Working Group was formed by volunteers among the invited attendees. Its members represent radiation oncology, medical physics, radiology, computer science, industry, and the NCI. In this perspective article written by members of the Training and Education Working Group, we provide
The main features of radiation by relativistic electrons are well approximated in the Weizsacker-Williams method of virtual quanta. This method is best known for its application to radiation during elementary particle collisions, but is equally useful in describing "classical" radiation emitted during the interaction of a single relativistic electron with an extended system, such as synchrotron radiation, undulator radiation, transition radiation and Cerenkov radiation.
Diagnostic imaging procedure using ionizing radiation has been growing due to its enormous benefits. However, using ionizing radiation is also associated with harmful biological effects. Therefore it is important to take consideration on harmful effects of ionizing radiation and have adequate awareness on the area, in order to protect people without limiting the benefits. In Ethiopia, the status of radiation protection practices have not been studied previously, which remain nearly unknown especially around the study area. Thus, in filing this gap the present study initiated to assess status of implementation of radiation protection system. General observation, questionnaire and dose rate measurements were used to get all necessary data for the study. The dose rate measurements at control room (CR), waiting room (WR) and inside X-ray room (XR) were carried out using well calibrated Thermo FH 40 G-L10 survey meter. The results of the general observation and the questionnaire showed poor practice of radiation protection system. The dose rate recordings from CR and WR, when the X-ray machine being switched on or off are within permissible allowed value at all hospitals. XR machine off
We study the impact of ultraviolet background (UVB) radiation field and the local stellar radiation on the H_I column density distribution f(N_HI) of damped Ly-alpha systems (DLAs) and sub-DLAs at z=3 using cosmological smoothed particle hydrodynamics simulations. We find that, in the previous simulations with an optically thin approximation, the UVB was sinking into the H_I cloud too deeply, and therefore we underestimated the f(N_HI) at 19 < log(N_HI) < 21.2 compared to the observations. If the UVB is shut off in the high-density regions with n_gas > 6 x 10^{-3} cm^{-3}, then we reproduce the observed f(N_HI) at z=3 very well. We also investigate the effect of local stellar radiation by post-processing our simulation with a radiative transfer code, and find that the local stellar radiation does not change the f(N_HI) very much. Our results show that the shape of f(N_HI) is determined primarily by the UVB with a much weaker effect by the local stellar radiation and that the optically thin approximation often used in cosmological simulation is inadequate to properly treat the ionization structure of neutral gas in and out of DLAs. Our result also indicates that the DLA gas
This paper presents the scenario that gravitational waves, generated in core-collapse of a pre-supernova star, can produce both electromagnetic radiation and sound radiation as gravitational waves propagate outward from the collapsing core. While the energy of this co-produced electromagnetic and sound radiation is orders of magnitude smaller than the initiating gravitational radiation, the power may be sufficient to re-ignite fusion outside the collapsing core. The non-equilibrium re-ignition of fusion, in roughly the same time frame as the strongest neutrino emissions, would change the configuration of the pre-supernova star and subsequently the ejecta and the evolution of the stellar expansion of the supernova remnant. Although the co-produced electromagnetic or sound radiation could not contribute directly to the supernova explosion, the associated non-equilibrium re-ignition of fusion would alter the state outside the core leaving an observable signature in the ejecta of the supernova remnant. The aim of this paper is to argue that including this hypothesized co-produced radiation in computational models of core collapse supernovae would contribute to the evolution of the stel
In this paper, a high-order gas-kinetic scheme is developed for the equation of radiation hydrodynamics in equilibrium-diffusion limit which describes the interaction between matter and radiation. To recover RHE, the Bhatnagar-Gross-Krook (BGK) model with modified equilibrium state is considered. In the equilibrium-diffusion limit, the time scales of radiation diffusion and hydrodynamic part are different, and it will make the time step very small for the fully explicit scheme. An implicit-explicit (IMEX) scheme is applied, in which the hydrodynamic part is treated explicitly and the radiation diffusion is treated implicitly. For the hydrodynamics part, a time dependent gas distribution function can be constructed by the integral solution of modified BGK equation, and the time dependent numerical fluxes can be obtained by taking moments of gas distribution function. For the radiation diffusion term, the nonlinear generalized minimal residual (GMRES) method is used. To achieve the temporal accuracy, a two-stage method is developed, which is an extension of two-stage method for hyperbolic conservation law. For the spatial accuracy, the multidimensional weighted essential non-oscillat
Ionizing radiation is known to delay the cell cycle progression. In particular after particle exposure significant delays have been observed and it has been shown that the extent of delay affects the expression of damage such as chromosome aberrations. Thus, to predict how cells respond to ionizing radiation and to derive reliable estimates of radiation risks, information about radiation-induced cell cycle perturbations is required. In the present study we describe and apply a method for retrieval of information about the time-course of all cell cycle phases from experimental data on the mitotic index only. We study the progression of mammalian cells through the cell cycle after exposure. The analysis reveals a prolonged block of damaged cells in the G2 phase. Furthermore, by performing an error analysis on simulated data valuable information for the design of experimental studies has been obtained. The analysis showed that the number of cells analyzed in an experimental sample should be at least 100 to obtain a relative error less than 20%.
It is widely believed that string theory easily allows for a QCD axion in the cosmologically favoured mass range. The required small decay constant, $f_a\ll M_P$, can be implemented by using a large compactification volume. This points to the Large Volume Scenario which in turn makes certain cosmological predictions: First, the closed string axion behaves similarly to a field-theoretic axion in the pre-inflationary scenario, i.e. the initial value can be tuned but one is constrained by isocurvature fluctuations. In addition, the volume represents a long-lived modulus that may lead to an early matter-dominated phase. Finally, the decay of the volume modulus to its own axion tends to overproduce dark radiation. In this paper we aim to carefully analyze the cosmology by studying models that not only allow for a QCD axion but also include inflation. Quite generally, limits on isocurvature fluctuations restrict us to relatively low-scale inflation, which in the present stringy context points to Kähler moduli inflation. As a novel feature we find that the lightest (volume) modulus couples strongly to the Higgs. It hence quickly decays to the SM, thus resolving the original dark radiation
The isolated black hole radiation of both Hawking and Zel'dovich are idealized abstractions as there is always another body to distort the potential. This is considered with respect to both gravitational tunneling, and black hole "no-hair" theorems. The effects of a second body are to lower the gravitational barrier of a black hole and to give the barrier a finite rather than infinite width so tha a particle can escape by tunneling (as in field emission) or over the top of the lowered barrier (as in Schottky emission). Thus radiation may be emitted from black holes in a process differing from that of Hawking radiation, P SH, which has been undetected for over 24 years. The radiated power from a black hole derived here is PR e ^2__ PSH, where e ^2__ is he ransmission probability for radiation through the barrier. This is similar to electric field emission of electrons from a metal in that the emission can in principle be modulated and beamed. The temperature and entropy of black holes are reexamined. Miniscule black holes herein may help explain the missing mass of the universe, accelerated expansion of the universe, and anomalous rotation of spiral galaxies. A gravitational interfe
The purpose of this study is to measure the internal radiation dose using a human blood sample. In the literature, there is no process that allows the direct measurement of the internal radiation dose received by a person. The luminescence counts from a blood sample having a laboratory-injected radiation dose and the waste blood of the patient injected with a radiopharmaceutical for diagnostic purposes were both measured. The decay and dose-response curves were plotted for the different doses. The doses received by the different blood aliquots can be determined by interpolating the luminescence counts to the dose-response curve. This study shows that the dose received by a person can be measured directly, simply and retrospectively by using only a very small amount of blood sample. The results will have important ramifications for the medicine and healthcare fields in particular. This will also be very important in cases of suspicion of radiation poisoning, malpractice and so on.
During the past decay many experimental configurations to improve the yield of hydrogen by electrolysis. These attempts include tests of different materials for the electrodes. This study proposes the use of γ-radiation of waste sources of nuclear reactors. The related experimental configuration can be reduced to boxes filled with water exposed to ionizing radiation and capacitors as electrodes as well-known in other technical disciplies. Test measurements based on radiation of a linear accelerator (6 MV beam) provided significant differences of the yield of hydrogen between with and without radiation.
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results show larger cell sizes are more susceptible to radiation damage with the largest 50 um SiPMs showing the greatest increase in current as a function of dose. Current increases were observed for doses as low at ~2 rad(Si) for protons and ~20 rad(Si) for electrons. The U.S. Naval Research Laboratory's (NRL) Strontium Iodide Radiation Instrument (SIRI-1) experienced a 528 uA increase in the bias current of the on-board 2x2 SensL J-series 60035 SiPM over its one-year mission in sun-synchronous orbit. The work here focuses on the increase in bulk current observed with increasing radiation damage and was performed to better quantify this effect as a function of dose for future mission. These include the future NRL mission SIRI-2, the follow on to SIRI-1, Glowbug and the GAGG Radiation Instrument (