Objective. Achieving appropriate spinopelvic alignment has been shown to be associated with improved clinical symptoms. However, measurement of spinopelvic radiographic parameters is time-intensive and interobserver reliability is a concern. Automated measurement tools have the promise of rapid and consistent measurements, but existing tools are still limited by some degree of manual user-entry requirements. This study presents a novel artificial intelligence (AI) tool called SpinePose that automatically predicts spinopelvic parameters with high accuracy without the need for manual entry. Methods. SpinePose was trained and validated on 761 sagittal whole-spine X-rays to predict sagittal vertical axis (SVA), pelvic tilt (PT), pelvic incidence (PI), sacral slope (SS), lumbar lordosis (LL), T1-pelvic angle (T1PA), and L1-pelvic angle (L1PA). A separate test set of 40 X-rays was labeled by 4 reviewers, including fellowship-trained spine surgeons and a fellowship-trained radiologist with neuroradiology subspecialty certification. Median errors relative to the most senior reviewer were calculated to determine model accuracy on test images. Intraclass correlation coefficients (ICC) were u
Current pelvic fixation techniques rely on rigid drilling tools, which inherently constrain the placement of rigid medical screws in the complex anatomy of pelvis. These constraints prevent medical screws from following anatomically optimal pathways and force clinicians to fixate screws in linear trajectories. This suboptimal approach, combined with the unnatural placement of the excessively long screws, lead to complications such as screw misplacement, extended surgery times, and increased radiation exposure due to repeated X-ray images taken ensure to safety of procedure. To address these challenges, in this paper, we present the design and development of a unique 4 degree-of-freedom (DoF) pelvic concentric tube steerable drilling robot (pelvic CT-SDR). The pelvic CT-SDR is capable of creating long S-shaped drilling trajectories that follow the natural curvatures of the pelvic anatomy. The performance of the pelvic CT-SDR was thoroughly evaluated through several S-shape drilling experiments in simulated bone phantoms.
Deep learning-based segmentation of genito-pelvic structures in MRI and CT is crucial for applications such as radiation therapy, surgical planning, and disease diagnosis. However, existing segmentation models often struggle with generalizability across imaging modalities, and anatomical variations. In this work, we propose RoMedFormer, a rotary-embedding transformer-based foundation model designed for 3D female genito-pelvic structure segmentation in both MRI and CT. RoMedFormer leverages self-supervised learning and rotary positional embeddings to enhance spatial feature representation and capture long-range dependencies in 3D medical data. We pre-train our model using a diverse dataset of 3D MRI and CT scans and fine-tune it for downstream segmentation tasks. Experimental results demonstrate that RoMedFormer achieves superior performance segmenting genito-pelvic organs. Our findings highlight the potential of transformer-based architectures in medical image segmentation and pave the way for more transferable segmentation frameworks.
Pelvic fractures, often caused by high-impact trauma, frequently require surgical intervention. Imaging techniques such as CT and 2D X-ray imaging are used to transfer the surgical plan to the operating room through image registration, enabling quick intraoperative adjustments. Specifically, segmenting pelvic fractures from 2D X-ray imaging can assist in accurately positioning bone fragments and guiding the placement of screws or metal plates. In this study, we propose a novel deep learning-based category and fragment segmentation (CFS) framework for the automatic segmentation of pelvic bone fragments in 2D X-ray images. The framework consists of three consecutive steps: category segmentation, fragment segmentation, and post-processing. Our best model achieves an IoU of 0.91 for anatomical structures and 0.78 for fracture segmentation. Results demonstrate that the CFS framework is effective and accurate.
Purpose: To evaluate the cumulative radiobiological impact of daily Megavoltage Cone-Beam Computed Tomography (MV-CBCT) imaging dose based on Normal Tissue Complication Probability (NTCP) and Excess Absolute Risk (EAR) of secondary malignancies among radiotherapy patients treated for breast, pelvic, and head and neck cancers. This study investigated whether MV-CBCT imaging dose warrants protocol personalization according to patient age, anatomical treatment site, and organ-specific radiosensitivity. Methods: This retrospective study included cohorts of breast (n=30), pelvic (n=17), and head and neck (n=20) cancer patients undergoing radiotherapy with daily MV-CBCT. Imaging plans using two common protocols (5 MU and 10 MU per fraction) were analyzed. NTCP values were estimated using logistic and Lyman-Kutcher-Burman (LKB) models, while EAR was calculated using Schneider's Organ Equivalent Dose (OED)-based model. Statistical analysis used paired t-tests, and results were further stratified by age (under 40, 40 to 60, over 60 years). Results: In breast cancer patients, NTCP for lung increased significantly under the 10 MU protocol (p<0.001). EAR was elevated in younger breast patie
The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversi
The semantic segmentation of pelvic organs via MRI has important clinical significance. Recently, deep learning-enabled semantic segmentation has facilitated the three-dimensional geometric reconstruction of pelvic floor organs, providing clinicians with accurate and intuitive diagnostic results. However, the task of labeling pelvic floor MRI segmentation, typically performed by clinicians, is labor-intensive and costly, leading to a scarcity of labels. Insufficient segmentation labels limit the precise segmentation and reconstruction of pelvic floor organs. To address these issues, we propose a semi-supervised framework for pelvic organ segmentation. The implementation of this framework comprises two stages. In the first stage, it performs self-supervised pre-training using image restoration tasks. Subsequently, fine-tuning of the self-supervised model is performed, using labeled data to train the segmentation model. In the second stage, the self-supervised segmentation model is used to generate pseudo labels for unlabeled data. Ultimately, both labeled and unlabeled data are utilized in semi-supervised training. Upon evaluation, our method significantly enhances the performance i
Accurate multi-needle localization in intraoperative CT images is crucial for optimizing seed placement in pelvic seed implant brachytherapy. However, this task is challenging due to poor image contrast and needle adhesion. This paper presents a novel approach that reframes needle localization as a tip-handle detection and matching problem to overcome these difficulties. An anchor-free network, based on HRNet, is proposed to extract multi-scale features and accurately detect needle tips and handles by predicting their centers and orientations using decoupled branches for heatmap regression and polar angle prediction. To associate detected tips and handles into individual needles, a greedy matching and merging (GMM) method designed to solve the unbalanced assignment problem with constraints (UAP-C) is presented. The GMM method iteratively selects the most probable tip-handle pairs and merges them based on a distance metric to reconstruct 3D needle paths. Evaluated on a dataset of 100 patients, the proposed method demonstrates superior performance, achieving higher precision and F1 score compared to a segmentation-based method utilizing the nnUNet model,thereby offering a more robust
Pelvic fractures pose significant diagnostic challenges, particularly in cases where fracture signs are subtle or invisible on standard radiographs. To address this, we introduce PelFANet, a dual-stream attention network that fuses raw pelvic X-rays with segmented bone images to improve fracture classification. The network employs Fused Attention Blocks (FABlocks) to iteratively exchange and refine features from both inputs, capturing global context and localized anatomical detail. Trained in a two-stage pipeline with a segmentation-guided approach, PelFANet demonstrates superior performance over conventional methods. On the AMERI dataset, it achieves 88.68% accuracy and 0.9334 AUC on visible fractures, while generalizing effectively to invisible fracture cases with 82.29% accuracy and 0.8688 AUC, despite not being trained on them. These results highlight the clinical potential of anatomy-aware dual-input architectures for robust fracture detection, especially in scenarios with subtle radiographic presentations.
Pelvic bone tumor resections remain significantly challenging due to complex three-dimensional anatomy and limited surgical visualization. Current navigation systems and patient-specific instruments, while accurate, present limitations including high costs, radiation exposure, workflow disruption, long production time, and lack of reusability. This study evaluates a real-time vision-guided surgical system combined with modular jigs to improve accuracy in pelvic bone tumor resections. A vision-guided surgical system combined with modular cutting jigs and real-time optical tracking was developed and validated. Five female pelvis sawbones were used, with each hemipelvis randomly assigned to either the vision-guided and modular jig system or traditional freehand method. A total of twenty resection planes were analyzed for each method. Accuracy was assessed by measuring distance and angular deviations from the planned resection planes. The vision-guided and modular jig system significantly improved resection accuracy compared to the freehand method, reducing the mean distance deviation from 2.07 $\pm$ 1.71 mm to 1.01 $\pm$ 0.78 mm (p=0.0193). In particular, all specimens resected using
This paper presents an approach for improving 2D/3D pelvis registration in optimization-based pose estimators using a learned initialization function. Current methods often fail to converge to the optimal solution when initialized naively. We find that even a coarse initializer greatly improves pose estimator accuracy, and improves overall computational efficiency. This approach proves to be effective also in challenging cases under more extreme pose variation. Experimental validation demonstrates that our method consistently achieves robust and accurate registration, enhancing the reliability of 2D/3D registration for clinical applications.
Accurate segmentation of Pelvic Radiation Injury (PRI) from Magnetic Resonance Images (MRI) is crucial for more precise prognosis assessment and the development of personalized treatment plans. However, automated segmentation remains challenging due to factors such as complex organ morphologies and confusing context. To address these challenges, we propose a novel Pattern Divide-and-Conquer Network (PDC-Net) for PRI segmentation. The core idea is to use different network modules to "divide" various local and global patterns and, through flexible feature selection, to "conquer" the Regions of Interest (ROI) during the decoding phase. Specifically, considering that our ROI often manifests as strip-like or circular-like structures in MR slices, we introduce a Multi-Direction Aggregation (MDA) module. This module enhances the model's ability to fit the shape of the organ by applying strip convolutions in four distinct directions. Additionally, to mitigate the challenge of confusing context, we propose a Memory-Guided Context (MGC) module. This module explicitly maintains a memory parameter to track cross-image patterns at the dataset level, thereby enhancing the distinction between glo
Automated landmark detection offers an efficient approach for medical professionals to understand patient anatomic structure and positioning using intra-operative imaging. While current detection methods for pelvic fluoroscopy demonstrate promising accuracy, most assume a fixed Antero-Posterior view of the pelvis. However, orientation often deviates from this standard view, either due to repositioning of the imaging unit or of the target structure itself. To address this limitation, we propose a novel framework that incorporates 2D/3D landmark registration into the training of a U-Net landmark prediction model. We analyze the performance difference by comparing landmark detection accuracy between the baseline U-Net, U-Net trained with Pose Estimation Loss, and U-Net fine-tuned with Pose Estimation Loss under realistic intra-operative conditions where patient pose is variable.
Surgical phase recognition (SPR) is a crucial element in the digital transformation of the modern operating theater. While SPR based on video sources is well-established, incorporation of interventional X-ray sequences has not yet been explored. This paper presents Pelphix, a first approach to SPR for X-ray-guided percutaneous pelvic fracture fixation, which models the procedure at four levels of granularity -- corridor, activity, view, and frame value -- simulating the pelvic fracture fixation workflow as a Markov process to provide fully annotated training data. Using added supervision from detection of bony corridors, tools, and anatomy, we learn image representations that are fed into a transformer model to regress surgical phases at the four granularity levels. Our approach demonstrates the feasibility of X-ray-based SPR, achieving an average accuracy of 93.8% on simulated sequences and 67.57% in cadaver across all granularity levels, with up to 88% accuracy for the target corridor in real data. This work constitutes the first step toward SPR for the X-ray domain, establishing an approach to categorizing phases in X-ray-guided surgery, simulating realistic image sequences to e
Early identification of individuals at risk of stroke remains a major clinical challenge, as prodromal motor im- pairments are often subtle and transient. In this pilot study, a wearable sensor-based framework is proposed for early pre- stroke risk screening using a single inertial measurement unit mounted on the sacral region to capture pelvic motion during gait and standing tasks. The pelvis is treated as a biomechanical proxy for global motor control, enabling the quantification of gait variability and postural drift as digital biomarkers of neurological instability. Raw inertial signals are processed using a sensor fusion pipeline to estimate pelvic kinematics, from which variability and nonlinear dynamic features are extracted. These features are subsequently used to train a machine learning model for risk stratification across control, pre-stroke, and stroke groups. Progressive increases in pelvic angular variability and postural instability are observed from the control to stroke groups, with the pre-stroke cohort exhibiting intermediate char- acteristics. As a proof-of-concept investigation, the proposed framework demonstrates the feasibility of using a minimal wearable con
Pelvic diseases in women of reproductive age represent a major global health burden, with diagnosis frequently delayed due to high anatomical variability, complicating MRI interpretation. Existing AI approaches are largely disease-specific and lack real-time compatibility, limiting generalizability and clinical integration. To address these challenges, we establish a benchmark framework for disease- and parameter-agnostic, real-time-compatible unsupervised anomaly detection in pelvic MRI. The method uses a residual variational autoencoder trained exclusively on healthy sagittal T2-weighted scans acquired across diverse imaging protocols to model normal pelvic anatomy. During inference, reconstruction error heatmaps indicate deviations from learned healthy structure, enabling detection of pathological regions without labeled abnormal data. The model is trained on 294 healthy scans and augmented with diffusion-generated synthetic data to improve robustness. Quantitative evaluation on the publicly available Uterine Myoma MRI Dataset yields an average area-under-the-curve (AUC) value of 0.736, with 0.828 sensitivity and 0.692 specificity. Additional inter-observer clinical evaluation e
Artificial intelligence is increasingly integrated into radiotherapy workflows, yet such pipelines remain vulnerable to out-of-distribution image data that may introduce unexpected behavior in clinical tasks. Deep learning-based anomaly detection for pelvic magnetic resonance imaging (MRI) remains largely unexplored, and transparent evaluation of its feasibility for full automation is limited. We developed and evaluated a fully automated, unsupervised anomaly-detection framework for pelvic and brain MRI. A two-stage framework was trained on reference images from public datasets: LUND-PROBE for pelvic MRI, and IXI, fastMRI, and fastMRI+ for brain MRI. In the first stage, MRI slices were compressed into discrete tokens; in the second, the distribution of normal tokens was modeled. Anomaly evidence was estimated by combining perceptual image differences with token-surprisal scores based on negative log-likelihood. Automated detection was evaluated on pelvic MRI with synthetic global and real clinical anomalies, and on brain MRI with clinically annotated fastMRI+ abnormalities. Sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and false-positive be
Reconstructing a 3D Stereo-lithography (STL) Model from 2D Contours of scanned structure in Digital Imaging and Communication in Medicine (DICOM) images is crucial to understand the geometry and deformity. Computed Tomography (CT) images are processed to enhance the contrast, reduce the noise followed by smoothing. The processed CT images are segmented using thresholding technique. 2D contour data points are extracted from segmented CT images and are used to construct 3D STL Models. The 2D contour data points may contain outliers as a result of segmentation of low resolution images and the geometry of the constructed 3D structure deviate from the actual. To cope with the imperfections in segmentation process, in this work we propose to use filtered 2D contour data points to reconstruct 3D STL Model. The filtered 2D contour points of each image are delaunay triangulated and joined layer-by-layer to reconstruct the 3D STL model. The 3D STL Model reconstruction is verified on i) 2D Data points of basic shapes and ii) Region of Interest (ROI) of human pelvic bone and are presented as case studies. The 3D STL model constructed from 2D contour data points of ROI of segmented pelvic bone
High-fidelity 3D anatomical reconstruction is a prerequisite for downstream clinical tasks such as preoperative planning, radiotherapy target delineation, and orthopedic implant design. We present Med-PU, a knowledge-driven framework that integrates volumetric medical image segmentation with point cloud upsampling for accurate pelvic shape reconstruction. Unlike landmark- or PCA-based statistical shape models, Med-PU learns an implicit anatomical prior directly from large-scale 3D shape data, enabling dense completion and refinement from sparse segmentation-derived point sets. The pipeline couples SAM-Med3D-based voxel segmentation, point extraction, deep upsampling, and surface reconstruction, yielding smooth and topologically consistent meshes. We evaluate Med-PU on pelvic CT datasets (MedShapePelvic for training and Pelvic1k for validation), benchmarking against state-of-the-art upsampling methods using comprehensive geometry and surface metrics. Med-PU consistently improves surface quality and anatomical fidelity while reducing artifacts, demonstrating robustness across input densities. Although validated on the pelvis, the approach is anatomy-agnostic and applicable to other s
Accurate MRI-to-CT synthesis could enable MR-only pelvic workflows by providing CT-like images with bone details while avoiding additional ionizing radiation. In this work, we investigate recently proposed drifting models for synthesizing pelvis CT images from MRI and benchmark them against convolutional neural networks (UNet, VAE), a generative adversarial network (WGAN-GP), a physics-inspired probabilistic model (PPFM), and diffusion-based methods (FastDDPM, DDIM, DDPM). Experiments are performed on two complementary datasets: Gold Atlas Male Pelvis and the SynthRAD2023 pelvis subset. Image fidelity and structural consistency are evaluated with SSIM, PSNR, and RMSE, complemented by qualitative assessment of anatomically critical regions such as cortical bone and pelvic soft-tissue interfaces. Across both datasets, the proposed drifting model achieves high SSIM and PSNR and low RMSE, surpassing strong diffusion baselines and conventional CNN-, VAE-, GAN-, and PPFM-based methods. Visual inspection shows sharper cortical bone edges, improved depiction of sacral and femoral head geometry, and reduced artifacts or over-smoothing, particularly at bone-air-soft tissue boundaries. Moreov