In ophthalmic surgery, developing an AI system capable of interpreting surgical videos and predicting subsequent operations requires numerous ophthalmic surgical videos with high-quality annotations, which are difficult to collect due to privacy concerns and labor consumption. Text-guided video generation (T2V) emerges as a promising solution to overcome this issue by generating ophthalmic surgical videos based on surgeon instructions. In this paper, we present Ophora, a pioneering model that can generate ophthalmic surgical videos following natural language instructions. To construct Ophora, we first propose a Comprehensive Data Curation pipeline to convert narrative ophthalmic surgical videos into a large-scale, high-quality dataset comprising over 160K video-instruction pairs, Ophora-160K. Then, we propose a Progressive Video-Instruction Tuning scheme to transfer rich spatial-temporal knowledge from a T2V model pre-trained on natural video-text datasets for privacy-preserved ophthalmic surgical video generation based on Ophora-160K. Experiments on video quality evaluation via quantitative analysis and ophthalmologist feedback demonstrate that Ophora can generate realistic and re
The advancement of general medical Multimodal Large Language Models (MLLMs) has shown great potential for building conversational assistants to support clinical diagnosis. However, their adaptation to highly specialized domains such as ophthalmology remains underexplored, primarily due to the scarcity of large-scale, domain-specific instruction-tuning data. Existing ophthalmic datasets for conversational agents are often limited in scale and largely rely on images from established public benchmarks, limiting the scalability of ophthalmic MLLMs and their ability to capture real-world clinical complexity. To address this gap, we propose $\textbf{OphIn-Engine}$, an ophthalmology-specific instruction data curation pipeline that constructs high-quality instruction data from open-access ophthalmology web-scale videos. The pipeline integrates multimodal transcription for extracting image-transcript pairs, visual cue separation and scoring for identifying clinically relevant visual descriptions, and instruction synthesis with quality control for generating accurate and diverse clinical dialogues. Using this engine, we introduce $\textbf{OphIn-500K}$, a large-scale multimodal ophthalmology
Foundation models (FMs) have shown great promise in medical image analysis by improving generalization across diverse downstream tasks. In ophthalmology, several FMs have recently emerged, but there is still no clear answer to fundamental questions: Which FM performs the best? Are they equally good across different tasks? What if we combine all FMs together? To our knowledge, this is the first study to systematically evaluate both single and fused ophthalmic FMs. To address these questions, we propose FusionFM, a comprehensive evaluation suite, along with two fusion approaches to integrate different ophthalmic FMs. Our framework covers both ophthalmic disease detection (glaucoma, diabetic retinopathy, and age-related macular degeneration) and systemic disease prediction (diabetes and hypertension) based on retinal imaging. We benchmarked four state-of-the-art FMs (RETFound, VisionFM, RetiZero, and DINORET) using standardized datasets from multiple countries and evaluated their performance using AUC and F1 metrics. Our results show that DINORET and RetiZero achieve superior performance in both ophthalmic and systemic disease tasks, with RetiZero exhibiting stronger generalization on
Visual Question Answering (VQA) holds great promise for clinical support, particularly in ophthalmology, where retinal fundus photography is essential for diagnosis. However, ophthalmic VQA benchmarks primarily emphasize answer accuracy, neglecting the explicit visual evidence necessary for clinical interpretability. In this work, we introduce FundusGround, a new benchmark for clinically interpretable ophthalmic VQA with spatially-grounded lesion evidence. Specifically, we propose a three-stage pipeline that collects 10,719 fundus images with 15,595 image-level meticulously annotated lesions. To ensure anatomical consistency and clinical validity, all lesions are spatially localized using the Early Treatment Diabetic Retinopathy Study (ETDRS) grid, enabling standardized mapping to nine clinically meaningful retinal regions. Built upon this structured lesion evidence, 72,706 questions are then generated spanning four formats: open-ended, closed-ended, single-choice, and multiple-choice. We further benchmark multiple general- and medical- large vision-language models using dual metrics for answer accuracy and lesion-level reasoning. The experiments demonstrate that incorporating lesi
The conventional manufacturing of ophthalmic lenses is an inefficient subtractive process where up to 97% of the material is discarded through grinding, polishing, and edging. Fluidic Shaping has emerged as a powerful alternative, utilizing surface tension to form optical-quality surfaces. While the approach enabled the creation of ophthalmic lenses without grinding or polishing, it was limited to lenses with a circular or elliptical footprint and still required the wasteful edging process to fit the lenses into the eyewear rims. Here, the Cookie Cutter algorithm is introduced, generalizing the Fluidic Shaping approach to be applicable to arbitrary domains, thus eliminating all subtractive processes. This mathematical framework calculates the unique varying edge-height required for a boundary frame, allowing a liquid polymer to naturally settle into a target spherocylindrical prescription within an arbitrary rim footprint. By utilizing neutral buoyancy to negate gravity, the liquid polymer is shaped solely by surface tension and subsequently cured, resulting in a lens that fits directly into commercial eyewear rims without any mechanical post-processing. The method is validated exp
Despite significant progress in Multi-modal Large Language Models (MLLMs), their clinical reasoning capacity for multi-modal diagnosis remains largely unexamined. Current benchmarks, mostly single-modality data, can't evaluate progressive reasoning and cross-modal integration essential for clinical practice. We introduce the Cross-Modality Progressive Clinical Reasoning (X-PCR) benchmark, the first comprehensive evaluation of MLLMs through a complete ophthalmology diagnostic workflow, with two reasoning tasks: 1) a six-stage progressive reasoning chain spanning image quality assessment to clinical decision-making, and 2) a cross-modality reasoning task integrating six imaging modalities. The benchmark comprises 26,415 images and 177,868 expert-verified VQA pairs curated from 51 public datasets, covering 52 ophthalmic diseases. Evaluation of 21 MLLMs reveals critical gaps in progressive reasoning and cross-modal integration. Dataset and code: https://github.com/CVI-SZU/X-PCR.
Medical Large Language Models (MLLMs) play a crucial role in ophthalmic diagnosis, holding significant potential to address vision-threatening diseases. However, their accuracy is constrained by hallucinations stemming from limited ophthalmic knowledge, insufficient visual localization and reasoning capabilities, and a scarcity of multimodal ophthalmic data, which collectively impede precise lesion detection and disease diagnosis. Furthermore, existing medical benchmarks fail to effectively evaluate various types of hallucinations or provide actionable solutions to mitigate them. To address the above challenges, we introduce EH-Benchmark, a novel ophthalmology benchmark designed to evaluate hallucinations in MLLMs. We categorize MLLMs' hallucinations based on specific tasks and error types into two primary classes: Visual Understanding and Logical Composition, each comprising multiple subclasses. Given that MLLMs predominantly rely on language-based reasoning rather than visual processing, we propose an agent-centric, three-phase framework, including the Knowledge-Level Retrieval stage, the Task-Level Case Studies stage, and the Result-Level Validation stage. Experimental results s
We present VisionFM, a foundation model pre-trained with 3.4 million ophthalmic images from 560,457 individuals, covering a broad range of ophthalmic diseases, modalities, imaging devices, and demography. After pre-training, VisionFM provides a foundation to foster multiple ophthalmic artificial intelligence (AI) applications, such as disease screening and diagnosis, disease prognosis, subclassification of disease phenotype, and systemic biomarker and disease prediction, with each application enhanced with expert-level intelligence and accuracy. The generalist intelligence of VisionFM outperformed ophthalmologists with basic and intermediate levels in jointly diagnosing 12 common ophthalmic diseases. Evaluated on a new large-scale ophthalmic disease diagnosis benchmark database, as well as a new large-scale segmentation and detection benchmark database, VisionFM outperformed strong baseline deep neural networks. The ophthalmic image representations learned by VisionFM exhibited noteworthy explainability, and demonstrated strong generalizability to new ophthalmic modalities, disease spectrum, and imaging devices. As a foundation model, VisionFM has a large capacity to learn from div
Early ophthalmic screening in low-resource and remote settings is constrained by access to specialized equipment and trained practitioners. We present SKINOPATHY AI, a smartphone-first web application that delivers five complementary, explainable screening modules entirely through commodity mobile hardware: (1) redness quantification via LAB a* color-space normalization; (2) blink-rate estimation using MediaPipe FaceMesh Eye Aspect Ratio (EAR) with adaptive thresholding; (3) pupil light reflex characterization through Pupil-to-Iris Ratio (PIR) time-series analysis; (4) scleral color indexing foricterus and anemia proxies via LAB/HSV statistics; and (5) iris-landmark-calibrated lesion encroachment measurement with millimeter-scale estimates and longitudinal trend tracking. The system is implemented as a React/FastAPI stack with OpenCV and MediaPipe, MongoDB-backed session persistence, and PDF report generation. All algorithms are fully deterministic, privacy-preserving, and designed for non-diagnostic consumer triage. We detail system architecture, algorithm design, evaluation methodology, clinical context, and ethical boundaries of the platform. SKINOPATHY AI demonstrates that mult
Domain specific large language models are increasingly used to support patient education, triage, and clinical decision making in ophthalmology, making rigorous evaluation essential to ensure safety and accuracy. This study evaluated four small medical LLMs Meerkat-7B, BioMistral-7B, OpenBioLLM-8B, and MedLLaMA3-v20 in answering ophthalmology related patient queries and assessed the feasibility of LLM based evaluation against clinician grading. In this cross sectional study, 180 ophthalmology patient queries were answered by each model, generating 2160 responses. Models were selected for parameter sizes under 10 billion to enable resource efficient deployment. Responses were evaluated by three ophthalmologists of differing seniority and by GPT-4-Turbo using the S.C.O.R.E. framework assessing safety, consensus and context, objectivity, reproducibility, and explainability, with ratings assigned on a five point Likert scale. Agreement between LLM and clinician grading was assessed using Spearman rank correlation, Kendall tau statistics, and kernel density estimate analyses. Meerkat-7B achieved the highest performance with mean scores of 3.44 from Senior Consultants, 4.08 from Consulta
Cataract surgery remains one of the most widely performed and effective procedures for vision restoration. Effective surgical planning requires integrating diverse clinical examinations for patient assessment, intraocular lens (IOL) selection, and risk evaluation. Large language models (LLMs) have shown promise in supporting clinical decision-making. However, existing LLMs often lack the domain-specific expertise to interpret heterogeneous ophthalmic data and provide actionable surgical plans. To enhance the model's ability to interpret heterogeneous ophthalmic reports, we propose a knowledge-driven Multi-Agent System (MAS), where each agent simulates the reasoning process of specialist ophthalmologists, converting raw clinical inputs into structured, actionable summaries in both training and deployment stages. Building on MAS, we introduce CataractSurg-80K, the first large-scale benchmark for cataract surgery planning that incorporates structured clinical reasoning. Each case is annotated with diagnostic questions, expert reasoning chains, and structured surgical recommendations. We further introduce Qwen-CSP, a domain-specialized model built on Qwen-4B, fine-tuned through a multi
Medical image classification is a core task in computer-aided diagnosis (CAD), playing a pivotal role in early disease detection, treatment planning, and patient prognosis assessment. In ophthalmic practice, fluorescein fundus angiography (FFA) and indocyanine green angiography (ICGA) provide hemodynamic and lesion-structural information that conventional fundus photography cannot capture. However, due to the single-modality nature, subtle lesion patterns, and significant inter-device variability, existing methods still face limitations in generalization and high-confidence prediction. To address these challenges, we propose CLEAR-Mamba, an enhanced framework built upon MedMamba with optimizations in both architecture and training strategy. Architecturally, we introduce HaC, a hypernetwork-based adaptive conditioning layer that dynamically generates parameters according to input feature distributions, thereby improving cross-domain adaptability. From a training perspective, we develop RaP, a reliability-aware prediction scheme built upon evidential uncertainty learning, which encourages the model to emphasize low-confidence samples and improves overall stability and reliability. We
Accurate 3D reconstruction of hands and instruments is critical for vision-based analysis of ophthalmic microsurgery, yet progress has been hampered by the lack of realistic, large-scale datasets and reliable annotation tools. In this work, we introduce OphNet-3D, the first extensive RGB-D dynamic 3D reconstruction dataset for ophthalmic surgery, comprising 41 sequences from 40 surgeons and totaling 7.1 million frames, with fine-grained annotations of 12 surgical phases, 10 instrument categories, dense MANO hand meshes, and full 6-DoF instrument poses. To scalably produce high-fidelity labels, we design a multi-stage automatic annotation pipeline that integrates multi-view data observation, data-driven motion prior with cross-view geometric consistency and biomechanical constraints, along with a combination of collision-aware interaction constraints for instrument interactions. Building upon OphNet-3D, we establish two challenging benchmarks-bimanual hand pose estimation and hand-instrument interaction reconstruction-and propose two dedicated architectures: H-Net for dual-hand mesh recovery and OH-Net for joint reconstruction of two-hand-two-instrument interactions. These models le
Multimodal ophthalmic imaging-based diagnosis integrates color fundus image with optical coherence tomography (OCT) to provide a comprehensive view of ocular pathologies. However, the uneven global distribution of healthcare resources often results in real-world clinical scenarios encountering incomplete multimodal data, which significantly compromises diagnostic accuracy. Existing commonly used pipelines, such as modality imputation and distillation methods, face notable limitations: 1)Imputation methods struggle with accurately reconstructing key lesion features, since OCT lesions are localized, while fundus images vary in style. 2)distillation methods rely heavily on fully paired multimodal training data. To address these challenges, we propose a novel multimodal alignment and fusion framework capable of robustly handling missing modalities in the task of ophthalmic diagnostics. By considering the distinctive feature characteristics of OCT and fundus images, we emphasize the alignment of semantic features within the same category and explicitly learn soft matching between modalities, allowing the missing modality to utilize existing modality information, achieving robust cross-m
Visual impairment represents a major global health challenge, with multimodal imaging providing complementary information that is essential for accurate ophthalmic diagnosis. This comprehensive survey systematically reviews the latest advances in multimodal deep learning methods in ophthalmology up to the year 2025. The review focuses on two main categories: task-specific multimodal approaches and large-scale multimodal foundation models. Task-specific approaches are designed for particular clinical applications such as lesion detection, disease diagnosis, and image synthesis. These methods utilize a variety of imaging modalities including color fundus photography, optical coherence tomography, and angiography. On the other hand, foundation models combine sophisticated vision-language architectures and large language models pretrained on diverse ophthalmic datasets. These models enable robust cross-modal understanding, automated clinical report generation, and decision support. The survey critically examines important datasets, evaluation metrics, and methodological innovations including self-supervised learning, attention-based fusion, and contrastive alignment. It also discusses
Multimodal large language models (MLLMs) have recently demonstrated remarkable reasoning abilities with reinforcement learning paradigm. Although several multimodal reasoning models have been explored in the medical domain, most of them focus exclusively on basic reasoning, which refers to shallow inference based on visual feature matching. However, real-world clinical diagnosis extends beyond basic reasoning, demanding reasoning processes that integrate heterogeneous clinical information (such as chief complaints and medical history) with multimodal medical imaging data. To bridge this gap, we introduce MM-Retinal-Reason, the first ophthalmic multimodal dataset with the full spectrum of perception and reasoning. It encompasses both basic reasoning tasks and complex reasoning tasks, aiming to enhance visual-centric fundamental reasoning capabilities and emulate realistic clinical thinking patterns. Building upon MM-Retinal-Reason, we propose OphthaReason, the first ophthalmology-specific multimodal reasoning model with step-by-step reasoning traces. To enable flexible adaptation to both basic and complex reasoning tasks, we specifically design a novel method called Uncertainty-Awar
High-fidelity surgical video generation can greatly improve medical training and the development of AI, adapting these generative models for precise video editing remains a formidable challenge. Modifying surgical attributes, such as instrument tissue interactions or procedural phases is challenging due to the strict anatomical and temporal constraints. In this paper, we propose OphEdit, a novel training-free framework for the text-guided editing of ophthalmic surgical videos. Our approach leverages a deterministic second-order ODE inversion pipeline to capture Attention Value (V) tensors from the original video. By selectively injecting these stored tensors into the conditional Classifier-Free Guidance (CFG) branch during the denoising phase, OphEdit rigorously preserves the intricate anatomical geometry of the eye while seamlessly mapping text-driven semantic modifications onto the video stream. Clinical evaluations demonstrates that OphEdit effectively handles complex surgical transformations, such as instrument swaps and procedural variations, with superior structural fidelity and temporal consistency compared to natural-domain video editors. Our work represents the first appli
Purpose: The integration of multimodal imaging into operating rooms paves the way for comprehensive surgical scene understanding. In ophthalmic surgery, by now, two complementary imaging modalities are available: operating microscope (OPMI) imaging and real-time intraoperative optical coherence tomography (iOCT). This first work toward temporal OPMI and iOCT feature fusion demonstrates the potential of multimodal image processing for multi-head prediction through the example of precise instrument tracking in vitreoretinal surgery. Methods: We propose a multimodal, temporal, real-time capable network architecture to perform joint instrument detection, keypoint localization, and tool-tissue distance estimation. Our network design integrates a cross-attention fusion module to merge OPMI and iOCT image features, which are efficiently extracted via a YoloNAS and a CNN encoder, respectively. Furthermore, a region-based recurrent module leverages temporal coherence. Results: Our experiments demonstrate reliable instrument localization and keypoint detection (95.79% mAP50) and show that the incorporation of iOCT significantly improves tool-tissue distance estimation, while achieving real-t
Ophthalmic image segmentation serves as a critical foundation for ocular disease diagnosis. Although fully convolutional neural networks (CNNs) are commonly employed for segmentation, they are constrained by inductive biases and face challenges in establishing long-range dependencies. Transformer-based models address these limitations but introduce substantial computational overhead. Recently, a simple yet efficient Multilayer Perceptron (MLP) architecture was proposed for image classification, achieving competitive performance relative to advanced transformers. However, its effectiveness for ophthalmic image segmentation remains unexplored. In this paper, we introduce MM-UNet, an efficient Mixed MLP model tailored for ophthalmic image segmentation. Within MM-UNet, we propose a multi-scale MLP (MMLP) module that facilitates the interaction of features at various depths through a grouping strategy, enabling simultaneous capture of global and local information. We conducted extensive experiments on both a private anterior segment optical coherence tomography (AS-OCT) image dataset and a public fundus image dataset. The results demonstrated the superiority of our MM-UNet model in comp
Purpose: To develop a bilingual multimodal visual question answering (VQA) benchmark for evaluating VLMs in ophthalmology. Methods: Ophthalmic image posts and associated captions published between January 1, 2016, and December 31, 2024, were collected from WeChat Official Accounts. Based on these captions, bilingual question-answer (QA) pairs in Chinese and English were generated using GPT-4o-mini. QA pairs were categorized into six subsets by question type and language: binary (Binary_CN, Binary_EN), single-choice (Single-choice_CN, Single-choice_EN), and open-ended (Open-ended_CN, Open-ended_EN). The benchmark was used to evaluate the performance of three VLMs: GPT-4o, Gemini 2.0 Flash, and Qwen2.5-VL-72B-Instruct. Results: The final OphthalWeChat dataset included 3,469 images and 30,120 QA pairs across 9 ophthalmic subspecialties, 548 conditions, 29 imaging modalities, and 68 modality combinations. Gemini 2.0 Flash achieved the highest overall accuracy (0.548), outperforming GPT-4o (0.522, P < 0.001) and Qwen2.5-VL-72B-Instruct (0.514, P < 0.001). It also led in both Chinese (0.546) and English subsets (0.550). Subset-specific performance showed Gemini 2.0 Flash excelled i