Osseointegration is crucial to the success of biomedical implants. Additive manufacturing of implants offers a high degree of design freedom, enabling precise control over implant geometry and material composition. Bioactive glass (BG) can substantially enhance bone binding and bioactivity; however, limited research has been conducted on its incorporation into additively manufactured implants. The performance of BG varies depending on the incorporation method, and the spatial and temporal evolution of its integration remains unclear. In this study, we synthesized Ti-6Al-4V/58S BG composites by using the selective laser melting method and systematically compared the effects of BG coating and doping in additively manufactured implants. In vivo histological results from animal tests were statistically analyzed and discussed in terms of osseointegration over 4- and 12-week periods. Bone-to-implant contact (BIC) and bone density (BD) were used as quantitative metrics to evaluate interactions between the implants and surrounding bone. Our findings indicate that both BG-doped and BG-coated implants accelerated bone ingrowth during the early stages of healing. BG-coated implants demonstrat
Biomedical implants offer transformative tools to improve medical outcomes. To realize minimally invasive implants with miniaturized volume and weight, wireless power transfer has been extensively studied to replace bulky batteries that dominate the volume of traditional implants and require surgical replacements. Ultra-sonic and magnetoelectric WPT modalities, which leverage low frequency acoustic electrical coupling for energy transduction, become viable solutions for mm-scale receivers. This work presents a fully integrated power management unit for ME WPT in millimetric implants. The PMU achieves load independent maximum power extraction and usage by continuously matching the impedance of the transducer, dynamically optimizing the power stage across varying input divided by load conditions, and reusing the storage energy to sustain the system when input power drops. Its parallel-input regulation and storing stages architecture prevent the cascading power loss. With the skewed-duty-cycle MPPT technique and regulation efficiency optimizer, the PMU achieves a peak MPPT efficiency of 98.5 percent and a peak system overall efficiency of 73.33 percent. Additionally, the PMU includes
High-strength composite hydrogels cellulose-polyacrylamide were synthesized by free-radical polymerization of acrylamide conducted inside the previously formed physical network of regenerated plant cellulose. Partial hydrolysis of the amide groups of these hydrogels yielded their ionic forms with a degree of hydrolysis of 0.1 and 0.25. The cylindrical hydrogel samples of three compositions were implanted in the preformed osteochondral defects of the rabbit's femoral knee joints. No signs of migration or disintegration of the tested implants were revealed in the course of in vivo tests as long as 90 and 120 days after the implantation. The mechanical behavior of both the virgin hydrogels-implants and the implants extracted from the joints after in vivo experiments was studied in detail. The morphology and chemical composition of the extracted implants were studied by SEM combined with the EDX method. The results obtained were shown that the mechanical characteristics of hydrogel implants remained practically unchanged after in vivo tests. The extracted implants, as well as the initial hydrogels, endured cyclic compression loading at the amplitude up to 50 %. Compression stresses up
The development of tissue-engineered cardiovascular implants can improve the lives of large segments of our society who suffer from cardiovascular diseases. Regenerative tissues are fabricated using a process called tissue maturation. Furthermore, it is highly challenging to produce cardiovascular regenerative implants with sufficient mechanical strength to withstand the loading conditions within the human body. Therefore, biohybrid implants for which the regenerative tissue is reinforced by standard reinforcement material (e.g. textile or 3d printed scaffold) can be an interesting solution. In silico models can significantly contribute to characterizing, designing, and optimizing biohybrid implants. The first step towards this goal is to develop a computational model for the maturation process of tissue-engineered implants. This paper focuses on the mechanical modeling of textile-reinforced tissue-engineered cardiovascular implants. First, we propose an energy-based approach to compute the collagen evolution during the maturation process. Then, we apply the concept of structural tensors to model the anisotropic behavior of the extracellular matrix and the textile scaffold. Next, t
Spatially distributed peripheral nerve recordings can be used to reconstruct motor intention and improve natural control of prosthetics However, many existing clinical solutions rely on percutaneous wires to access peripheral nerves; these sites are prone to infection and motion-induced electrode degradation, preventing chronic use. To address the need for fully wireless neural recording systems, this paper presents DustNet: a spatially-distributed network of ultrasonically-powered neural recording implants capable of supporting up to 8 simultaneously recording nodes over a single ultrasound link. To enable high throughput multi-implant communication, DustNet implements a time-division multiple-access (TDMA) protocol with up to 16-level amplitude modulation of the ultrasound backscatter that achieves up to 4x higher data rates than traditional on-off keying methods. Each neural implant consists of a 0.7x0.7x0.7 mm$^3$ piezoceramic transducer, a 100 nF off-chip capacitor, and an IC mounted on a flexible PCB. The implant IC was fabricated in a 28nm CMOS process and occupies an area of 0.43 mm$^2$. System functionality was verified at 90mm depth in oil, achieving a maximum measured da
Objective: This work aims to demonstrate a low-power, biomimetic auditory sensing concept for fully implantable cochlear implants. The approach draws inspiration from the frequency selectivity and temporal encoding of the cochlea, and uses neuromorphic spike generation to replace conventional signal processing blocks. The goal is to establish a compact, energy-efficient front-end architecture suitable for future implantable systems. Methods: An auditory sensing unit was implemented, consisting of a piezoelectric MEMS cantilever mechanically coupled to a single VO$_2$ nanogap Mott memristor-based oscillator. This configuration enables FFT-free, frequency-selective sensing and direct spike generation, forming a biomimetic auditory front end. The concept was experimentally examined using controlled mechanical excitation. Results: The sensing unit exhibited frequency-selective detection of mechanical vibrations in the nanometer to tens-of-nanometers displacement range and generated biomimetic spiking waveforms. Spike rate-encoding of the input amplitude was demonstrated, with output spiking frequencies tunable between approximately 100 Hz and 1 kHz depending on the excitation level. Th
Background. Osteoarthritis affects about 528 million people worldwide, causing pain and stiffness in the joints. Arthroplasty is commonly performed to treat joint osteoarthritis, reducing pain and improving mobility. Nevertheless, a significant share of patients remain unsatisfied with their surgery. Personalised arthroplasty was introduced to improve surgical outcomes however current solutions require delays, making it difficult to integrate in clinical routine. We propose a fully automated workflow to design patient-specific implants for total knee arthroplasty. Methods. The proposed pipeline first uses artificial neural networks to segment the femur and tibia proximal and distal extremities. Then the full bones are reconstructed using augmented statistical shape models, combining shape and landmarks information. Finally, 77 morphological parameters are computed to design patient-specific implants. The developed workflow has been trained on 91 CT scans and evaluated on 41 CT scans, in terms of accuracy and execution time. Results. The workflow accuracy was $0.4\pm0.2mm$ for segmentation, $1.0\pm0.3mm$ for full bone reconstruction, and $2.2\pm1.5mm$ for anatomical landmarks determ
Despite significant advancements in wireless smart implants over the last two decades, current implantable devices still operate passively and require additional electronic modules for wireless transmission of the stored biological data. To address these challenges, we propose an innovative wireless force sensing paradigm for implantable systems through the integration of mechanical metamaterials and nano energy harvesting technologies. We demonstrate composite mechanical metamaterial implants capable of serving as all-in-one wireless force sensing units, incorporating functions for power generation, sensing and transmission with ultra-low power requirements. In this alternative communication approach, the electrical signals harvested by the implants from mechanical stimuli are utilized directly for the wireless transmission of the sensed data. We conduct experimental and theoretical studies to demonstrate the wireless detection of the generated strain-induced polarization electric field using electrodes. The feasibility of the proposed wireless force sensing approach is evaluated through a proof-of-concept orthopedic implant in the form of a total knee replacement. The findings in
The development of tissue engineering structures (scaffolds) for the reconstruction of bone tissue defects is the relevant task of modern biomedical materials science. Compared to metal-based structures, polymer constructs provide numerous advantages, among them - better processibility and metallosis avoidance. Owing to its high mechanical performance and biocompatibility, polyetherketoneketone (PEKK) became a promising material for the development of such structures. Previously, a method for the immobilization of hydroxyapatite (HAp) on PEKK surface was proposed by our group for the enhancement of stem cell adhesion. In the present study, we propose a single-step method of HAp immobilization on the surface of 3D-printed porous PEKK implants. The proposed approach allowed to preserve the morphology (pore diameter, width of the printed lines) of the pristine implants. With that, up to 35.0+-14.0 % of the sample surface were coated with HAp particles, which resulted in improved hydrophilicity (0 degrees water contact angle). The calcium and phosphorus content on the surface of the modified samples was up to 17.4+-4.1 and 8.0+-1.7 wt. %, respectively. Importantly, the proposed modific
Wireless communication is critical for the non-invasive in-situ monitoring of vital signs in deep tissues. Wireless ultrasonic links demonstrated so far solved the shortcomings of electromagnetic wave-based communication methods. However, they either require highly customized and complex designs for the implant electronics or rely on physical changes in implanted metamaterials. Here, we report a wireless, passive, frequency-based, and electronics-free ultrasonic communication method for deep tissue sensor implants. The device consists of a piezoelectric crystal used as the ultrasonic antenna, considerably simplifying the implant design, and can be integrated with any capacitive implantable sensor. We demonstrate the applicability of the passive communication method using a commercial pressure sensor at a depth of 5 cm with decent precision and accuracy.
Self-powered intracardiac implant devices show great promise for future clinical applications due to their extended operational lifespan and the potential to reduce the need for high-risk repeat surgeries. This study investigates the feasibility of harvesting energy from cardiac motion through in vivo testing of intracardiac devices. Comprehensive three-dimensional translational and rotational cardiac motions are captured in a porcine model using a miniaturized 9-degree-of-freedom motion sensor implanted at six strategic epicardial sites. Kinematic criteria are developed to evaluate the energy harvesting potential of each implant site based on the available kinetic energy, acceleration, and jerk factors. The recorded heart motion signals are analyzed and applied to a conceptual energy harvester proposed to identify the optimal implant site. The results reveal that the left ventricular apex emerges as a preferable site for energy harvesting, particularly at moderate heart rates. These findings offer valuable insights into optimizing self-powered intracardiac implants, reducing dependency on battery replacements, and enhancing long-term patient safety.
This work proposes a gradient-based method to design bone implants using triply-periodic minimal surfaces (TPMS) of spatially varying thickness to maximize bone in-growth. Bone growth into the implant is estimated using a finite element based mechanobiological model considering the magnitude and frequency of in vivo loads, as well as the density distribution of the surrounding bone. The wall thicknesses of the implant unit cells are determined via linear interpolation of the thicknesses over a user defined grid of control points, avoiding mesh dependency and providing control over the sensitivity computation costs. The TPMS structure is modeled as a homogenized material to reduce computational cost. Local properties of the implant are determined at run-time on an element-by-element basis using a pre-constructed surrogate model of the TPMS's physical and geometric properties as a function of the local wall thickness and the density of in-grown bone. Design sensitivities of the bone growth within the implant are computed using the direct sensitivity method. The methodology is demonstrated on a cementless hip, optimizing the implant for bone growth subject to wall thickness constraint
Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in devices. Despite successful demonstrations of millimetric battery free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery. This article presents an omnidirectional WPT platform for millimetric bioelectronic implants, employing the emerging magnetoelectric (ME) WPT modality, and magnetic field steering technique based on multiple transmitter (TX) coils. To accurately sense the weak coupling in a miniature implant and adaptively control the multicoil TX array in a closed loop, we develop an active echo (AE) scheme using a tiny coil on the implant. Our prototype comprises a fully integrated 14.2 mm3 implantable stimulator embedding a custom low power system on chip (SoC) powered by an ME film, a TX with a custom three channel AE RX chip, and a multicoil TX array with mutual induct
In this paper, we propose and evaluate a method of generating low-cost device signatures for distributed wireless brain implants, using a Pseudo-Random Binary Sequence (PRBS) Generator that utilizes a modified Ring-Oscillator-based Physical Unclonable Function (RO-PUF). The modified RO-PUF's output is used as a seed for the PRBS generator, which creates a multi-bit output that can be mapped to a time-slot when the implant is allowed to communicate with the external world using duty-cycled time-division multiplexing. A 9-bit PRBS generator is shown in hardware (with a TSMC 65 nm test chip implementation) that demonstrates < 100 nW Power consumption in measurement (72% lower power and 78% lower area than a traditional 9-bit RO-PUF implementation), which supports 26 implants with the probability of time-slot collision being < 50%. This potentially creates a pathway for low-cost device signature generation for highly resource-constrained scenarios such as wireless, distributed neural implants.
Surface modification is an important topic to improve dental implants. Corundum residues, which are part of current dental implant blasting, disappeared on Straumann dental implants in recent publications. In our investigations of the surface of 4 different Straumann implants using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) we found the following three main findings: surfaces are nearly corundum-free, disseminated gap-framed corundum particles and significant molecular carbon residues. The data strongly suggest that Straumann applies a modified surface technology on dental implants to remove corundum residues and involving unclear carbons. One explanation could be, a Straumann patent involving a dextran coating allowing easy corundum particle removal by aqueous solution, while unintended molecular carbon residues cannot explain all findings. This change of the production process without a new approval by the FDA would be a violation of US federal law and the carbon bindings are a possible danger to patients.
This study aims to assess the composition of scattered particles generated in proton therapy for tumours situated proximal to titanium dental implants. The investigation involves decomposing the mixed field and recording Linear Energy Transfer (LET) spectra to quantify the influence of metallic dental inserts located behind the tumour. A conformal proton beam was used to deliver the treatment plan to an anthropomorphic head phantom with two types of implants (Ti and plastic) inserted in the target volume. The stray radiation resulting during the irradiation was detected by a hybrid semiconductor pixel detector MiniPIX Timepix3 that was placed distal to the Spread-out Bragg peak. Visualization and field decomposition of stray radiation were generated using algorithms trained in particle recognition based on artificial intelligence convolution neural networks (AI CNN). Spectral sensitive aspects of the scattered radiation were collected using two angular positions of the detector relative to the beam direction: 0 and 60°. Using AI CNN, 3 classes of particles were identified: protons, electrons & photons, ions & fast neutrons. Placing a Ti implant in the beam's path resulted i
Drug-releasing implants are gaining momentum in the treatment of glaucoma. However, they present several limitations, such as the inability to provide an even distribution of the drug in the trabecular meshwork. CFD simulations were used in this work to study the interplay between ocular fluid dynamics and drug diffusion to explore the options to achieve a homogeneous drug distribution in the target tissue. The analysis finds that thermal convective currents do not result in efficient mixing within the eye's anterior chamber. This results in highly localized drug delivery in the trabecular meshwork when using a gravity-placed cylindrical implant. Placing the implant in the posterior chamber results in improved mixing, although it presents the risk of therapeutical drugs being absorbed by the corneal endothelium instead of reaching the trabecular meshwork. Finally, a ring implant next to the trabecular meshwork is tested, which would give rise to a homogeneous concentration around the entirety of the trabecular meshwork. However, implanting a 360° ring with cylindrical cross-section next to the trabecular meshwork can entail significant surgical challenges, so the solution could con
Data collection and analysis from multiple implant nodes in humans can provide targeted medicine and treatment strategies that can prevent many chronic diseases. This data can be collected for a long time and processed using artificial intelligence (AI) techniques in a medical network for early detection and prevention of diseases. Additionally, machine learning (ML) algorithms can be applied for the analysis of big data for health monitoring of the population. Wireless powering, sensing, and communication are essential parts of future wireless implants that aim to achieve the aforementioned goals. In this paper, we present the technical development of a wireless implant that is powered by radio frequency (RF) at 401 MHz, with the sensor data being communicated to an on-body reader. The implant communication is based on two simultaneous wireless links: RF backscatter for implant-to-on-body communication and a galvanic link for intra-body implant-to-implant connectivity. It is demonstrated that RF powering, using the proposed compact antennas, can provide an efficient and integrable system for powering up to an 8 cm depth inside body tissues. Furthermore, the same antennas are utili
Millimeter-scale implants using ultrasound for power and communication have been proposed for a range of deep-tissue applications, including neural recording and stimulation. However, published implementations have shown high sensitivity to misalignment with the external ultrasound transducer. Ultrasonic beamforming using a phased array to these implants can improve tolerance to misalignment, reduce implant volume, and allow multiple implants to be operated simultaneously in different locations. This paper details the design of a custom planar phased array ultrasound system, which is capable of steering and focusing ultrasound power within a 3D volume. Analysis and simulation is performed to determine the choice of array element pitch, with special attention given to maximizing the power available at the implant while meeting FDA limits for diagnostic ultrasound. Time reversal is proposed as a computationally simple approach to beamforming that is robust despite scattering and inhomogeneity of the acoustic medium. This technique is demonstrated both in active drive and pulse-echo modes, and it is experimentally compared with other beamforming techniques by measuring energy transfer
As the commercial surgical guide design software usually does not support the export of implant position for pre-implantation data, existing methods have to scan the post-implantation data and map the implant to pre-implantation space to get the label of implant position for training. Such a process is time-consuming and heavily relies on the accuracy of registration algorithm. Moreover, not all hospitals have paired CBCT data, limitting the construction of multi-center dataset. Inspired by the way dentists determine the implant position based on the neighboring tooth texture, we found that even if the implant area is masked, it will not affect the determination of the implant position. Therefore, we propose to mask the implants in the post-implantation data so that any CBCT containing the implants can be used as training data. This paradigm enables us to discard the registration process and makes it possible to construct a large-scale multi-center implant dataset. On this basis, we proposes ImplantFairy, a comprehensive, publicly accessible dental implant dataset with voxel-level 3D annotations of 1622 CBCT data. Furthermore, according to the area variation characteristics of the