As the commercial surgical guide design software usually does not support the export of implant position for pre-implantation data, existing methods have to scan the post-implantation data and map the implant to pre-implantation space to get the label of implant position for training. Such a process is time-consuming and heavily relies on the accuracy of registration algorithm. Moreover, not all hospitals have paired CBCT data, limitting the construction of multi-center dataset. Inspired by the way dentists determine the implant position based on the neighboring tooth texture, we found that even if the implant area is masked, it will not affect the determination of the implant position. Therefore, we propose to mask the implants in the post-implantation data so that any CBCT containing the implants can be used as training data. This paradigm enables us to discard the registration process and makes it possible to construct a large-scale multi-center implant dataset. On this basis, we proposes ImplantFairy, a comprehensive, publicly accessible dental implant dataset with voxel-level 3D annotations of 1622 CBCT data. Furthermore, according to the area variation characteristics of the
In the design of surgical guides for implant placement, determining the precise implant position is a critical step. However, the implant region itself is often characterized by a lack of distinctive texture in medical images. Consequently, artificial intelligence (AI) models must infer the correct implant position and angulation (slope) primarily by analyzing the texture of the surrounding teeth, which poses a significant challenge. To address this, we propose ImplantMamba, a network architecture designed for long-range sequential modeling to integrate texture information from adjacent teeth. Our approach explicitly couples the regression of the implant position with its slope. The core of ImplantMamba is a hybrid encoder that combines Convolutional Neural Networks (CNNs) with Mamba layers. This design enables the network to hierarchically extract local anatomical features through CNNs while simultaneously modeling global contextual dependencies across the entire scan volume via Mamba's selective scan operations, leading to a more comprehensive understanding of the implant site. Furthermore, we introduce a Slope-Coupled Prediction Branch (SCP). This branch is designed to connect t
Peri-implant inflammation in orthodontic mini-implant may lead to patient discomfort and treatment failure. This study aims to evaluate the effects of diode laser application on the health of mini-implant, preventing peri-implantitis and promoting healing. A randomized controlled trial was conducted involving 30 orthodontic patients (12 males and 18 females, aged 18-32) who had mini-implants implanted on both sides of the maxilla for anterior teeth retraction. One side of each patient was assigned to either an experimental group receiving diode laser irradiation (650 nm, 25 mW) at specific postoperative intervals or a control group receiving simulated radiation. Clinical assessments included plaque index, modified sulcus bleeding index, probing depth, and incidence of peri-implant mucositis and implant mobility, measured at 1, 4, and 12 weeks post-implantation. Additionally, interleukin-1 beta (IL-1\b{eta}) levels in peri-implant fluid were analyzed via enzyme-linked immunosorbent assay (ELISA). Results indicated that the experimental group exhibited significantly lower plaque indices, sulcus bleeding indices, and probing depths (p < 0.05) compared to the control group. Moreover
Surgical guide plate is an important tool for the dental implant surgery. However, the design process heavily relies on the dentist to manually simulate the implant angle and depth. When deep neural networks have been applied to assist the dentist quickly locates the implant position, most of them are not able to determine the implant depth. Inspired by the video grounding task which localizes the starting and ending time of the target video segment, in this paper, we simplify the implant depth prediction as video grounding and develop a Texture Perceive Implant Depth Prediction Network (TPNet), which enables us to directly output the implant depth without complex measurements of oral bone. TPNet consists of an implant region detector (IRD) and an implant depth prediction network (IDPNet). IRD is an object detector designed to crop the candidate implant volume from the CBCT, which greatly saves the computation resource. IDPNet takes the cropped CBCT data to predict the implant depth. A Texture Perceive Loss (TPL) is devised to enable the encoder of IDPNet to perceive the texture variation among slices. Extensive experiments on a large dental implant dataset demonstrated that the pr
Brain-Computer Interfaces (BCIs) have revolutionized neuroscience applications, from motor rehabilitation to neuroergonomics. Traditional implantable BCIs with invasive microelectrode arrays pose challenges, notably the need for wired connections and inherent implantation risks. This paper introduces a battery-free wireless BCI system, consolidating an implant and its external supporting system. Our design centers on a dual-function antenna system: firstly, an inductive coupling mechanism enables wireless power transfer, sufficiently powering the implant's Application-Specific Integrated Circuit (ASIC) for stimulation and readout without an implant battery. Secondly, a backscatter antenna in the implant facilitates battery-free, high-data-rate wireless connectivity (up to 32 Mbps). This system not only enhances the BCI experience by eliminating wires but also retains data fidelity and energy efficiency, promising a safer, more efficient interface for tasks like robotic arm control.
Bimodal cochlear implant users show poor localization performance. One reason for this is a difference in the processing latency between the hearing aid and the cochlear implant side. It has been shown that reducing this latency difference acutely improves the localization performance of bimodal cochlear implant users. However, due to the frequency dependency of both the device latencies and the acoustic hearing ear, current frequency-independent latency adjustments cannot fully compensate for the differences, leaving open which latency adjustment is best. We therefore measured the localization performance of eleven bimodal cochlear implant users for multiple cochlear implant latencies. We confirm previous studies that adjusting the interaural latency improves localization in all eleven bimodal cochlear implant users. However, the latency that leads to the best localization performance for most subjects was not at the latency calculated to compensate for the interaural difference at intermediate frequencies (1 kHz). Nine of eleven subjects localized best with a cochlear implant latency that was slightly shorter than the calculated latency compensation.
Magnetocardiography system is a medical device that diagnoses cardiac disease by measuring magnetic fields generated from electric currents flowing through the myocardium. However, the accuracy of measurement data can be degraded if strong magnetic materials are present or magnetic field changes occur near the MCG system. With the widespread use of implants, the number of patients with metallic implants is increasing, but there is a lack of in-depth research on the potential impact of implant materials on the results of the MCG examination. This study aims to analyze the effect of implant materials on MCG measurements and establish relevant criteria. In this study, a 96-channel MCG system employing Superconducting Quantum Interference Device sensors, specifically first-order gradiometers based on the Double Relaxation Oscillation SQUID method, and a Magnetically Shielded Room were utilized. Ti6Al4V ELI was selected as the representative implant material sample. Experiments were conducted under extreme conditions, where a sample significantly larger than an actual implant was placed as close as possible to the sensors. As a result, when the implant material was at the minimum distan
While cervical arthroplasty using Total Disc Replacement (TDR) implants is an established treatment for persistent neck and arm pain, revision rates limit it from reaching its full potential. To address the underlying complications, we developed finite element simulation-driven design optimizations for a TDR's bone-implant interface and motion-preservation features. These automated processes explored high-dimensional design spaces iteratively through analysis of design variations interplay with spinal structures. The optimizations were metamodel-based using artificial neural networks and a hybrid optimizer. They optimized the motion-preservation zone towards replicating the asymptomatic spinal segment's ligaments strain profiles and its facet joint force profiles during main motions. This design process aims to minimize the risk for postoperative pain, avoidable degeneration and to restore segmental biomechanics, to prevent adjacent segment effects. Designs with single articulation and with dual articulation (with a mobile insert) were optimized. The bone-implant interface was optimized with the aim to minimize the risk for subsidence and implant migration. The optimizations improv
Accurate reconstruction of implanted knee models is crucial in orthopedic surgery and biomedical engineering, enhancing preoperative planning, optimizing implant design, and improving surgical outcomes. Traditional methods rely on labor-intensive and error-prone manual segmentation. This study proposes a novel approach using machine learning (ML) algorithms and morphing techniques for precise 3D reconstruction of implanted knee models. The methodology begins with acquiring preoperative imaging data, such as fluoroscopy or X-ray images of the patient's knee joint. A convolutional neural network (CNN) is then trained to automatically segment the femur contour of the implanted components, significantly reducing manual effort and ensuring high accuracy. Following segmentation, a morphing algorithm generates a personalized 3D model of the implanted knee joint, using the segmented data and biomechanical principles. This algorithm considers implant position, size, and orientation to simulate the knee joint's shape. By integrating morphological data with implant-specific parameters, the reconstructed models accurately reflect the patient's implant anatomy and configuration. The approach's
The design and benchtop operation of a wireless miniature epiretinal stimulator implant is reported. The implant is optically powered and controlled using safe illumination at near-infrared wavelengths. An application-specific integrated circuit (ASIC) hosting a digital control unit is used to control the implant's electrodes. The ASIC is powered using an advanced photovoltaic (PV) cell and programmed using a single photodiode. Diamond packaging technology is utilized to achieve high-density integration of the implant optoelectronic circuitry, as well as individual connections between a stimulator chip and 256 electrodes, within a 4.6 mm x 3.7 mm x 0.9 mm implant package. An ultrahigh efficiency PV cell with a monochromatic power conversion efficiency of 55% is used to power the implant. On-board photodetection circuity with a bandwidth of 3.7 MHz is used for forward data telemetry of stimulation parameters. In comparison to implants which utilize inductively coupled coils, laser power delivery enables a high degree of miniaturization and lower surgical complexity. The device presented combines the benefits of implant miniaturization and a flexible stimulation strategy provided by
This study presents a computational optimisation framework of a hip implant through the development of a functionally graded biomimetic lattice structure, whose design was structurally optimised to limit stress shielding. The optimisation technique was inspired by the inverse of a bone remodelling algorithm, promoting an even stress distribution throughout the design region, by reducing the density and consequently the stiffness, in regions where strain energy was higher than the reference level. The result of the optimisation technique provided a non-uniform graded density distribution field that showed lower density level on the sides of the implant stem, and higher material density around the medial axis of the stem. The optimised material distribution was captured using mapping of a triply periodic minimal surface lattice structure on the implant, which resulted in porous lattice surfaces inside the solid implant. The performance of the porous implant design was evaluated through implementation of a finite element bone remodelling algorithm and comparing the bone response with a femur with fully solid implant model, in terms of stress distribution and mass change. The results o
Self-powered intracardiac implant devices show great promise for future clinical applications due to their extended operational lifespan and the potential to reduce the need for high-risk repeat surgeries. This study investigates the feasibility of harvesting energy from cardiac motion through in vivo testing of intracardiac devices. Comprehensive three-dimensional translational and rotational cardiac motions are captured in a porcine model using a miniaturized 9-degree-of-freedom motion sensor implanted at six strategic epicardial sites. Kinematic criteria are developed to evaluate the energy harvesting potential of each implant site based on the available kinetic energy, acceleration, and jerk factors. The recorded heart motion signals are analyzed and applied to a conceptual energy harvester proposed to identify the optimal implant site. The results reveal that the left ventricular apex emerges as a preferable site for energy harvesting, particularly at moderate heart rates. These findings offer valuable insights into optimizing self-powered intracardiac implants, reducing dependency on battery replacements, and enhancing long-term patient safety.
Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in devices. Despite successful demonstrations of millimetric battery free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery. This article presents an omnidirectional WPT platform for millimetric bioelectronic implants, employing the emerging magnetoelectric (ME) WPT modality, and magnetic field steering technique based on multiple transmitter (TX) coils. To accurately sense the weak coupling in a miniature implant and adaptively control the multicoil TX array in a closed loop, we develop an active echo (AE) scheme using a tiny coil on the implant. Our prototype comprises a fully integrated 14.2 mm3 implantable stimulator embedding a custom low power system on chip (SoC) powered by an ME film, a TX with a custom three channel AE RX chip, and a multicoil TX array with mutual induct
In implant prosthesis treatment, the surgical guide of implant is used to ensure accurate implantation. However, such design heavily relies on the manual location of the implant position. When deep neural network has been proposed to assist the dentist in locating the implant position, most of them take a single slice as input, which do not fully explore 3D contextual information and ignoring the influence of implant slope. In this paper, we design a Text Guided 3D Context and Slope Aware Triple Network (TCSloT) which enables the perception of contextual information from multiple adjacent slices and awareness of variation of implant slopes. A Texture Variation Perception (TVP) module is correspondingly elaborated to process the multiple slices and capture the texture variation among slices and a Slope-Aware Loss (SAL) is proposed to dynamically assign varying weights for the regression head. Additionally, we design a conditional text guidance (CTG) module to integrate the text condition (i.e., left, middle and right) from the CLIP for assisting the implant position prediction. Extensive experiments on a dental implant dataset through five-fold cross-validation demonstrated that the
Statement of problem. Dental implant geometry affects the mechanical performance and fatigue behavior of butt-joint implant-supported restorations. However, failure of the implant component has been generally studied by ignoring the prosthetic screw, which is frequently the critical restoration component Purpose. Evaluate the effect of 3 main implant geometric parameters: the implant body diameter, the platform diameter, and the implant-abutment connection type (external versus internal butt-joint) on the fatigue life of the prosthetic screw. The experimental values were further compared with the theoretical ones obtained by using a previously published methodology M&M. 4 different designs of direct-to-implant dental restorations from the manufacturer BTI were tested. Forty-eight fatigue tests were performed in an axial fatigue testing machine according to ISO 14801. Linear regression models, 95% interval confidence bands for the linear regression, and 95% prediction intervals of the fatigue load-life results were obtained and compared through an analysis of covariance to determine the influence of the 3 parameters under study on the fatigue behavior Results. Linear regression
This work proposes a gradient-based method to design bone implants using triply-periodic minimal surfaces (TPMS) of spatially varying thickness to maximize bone in-growth. Bone growth into the implant is estimated using a finite element based mechanobiological model considering the magnitude and frequency of in vivo loads, as well as the density distribution of the surrounding bone. The wall thicknesses of the implant unit cells are determined via linear interpolation of the thicknesses over a user defined grid of control points, avoiding mesh dependency and providing control over the sensitivity computation costs. The TPMS structure is modeled as a homogenized material to reduce computational cost. Local properties of the implant are determined at run-time on an element-by-element basis using a pre-constructed surrogate model of the TPMS's physical and geometric properties as a function of the local wall thickness and the density of in-grown bone. Design sensitivities of the bone growth within the implant are computed using the direct sensitivity method. The methodology is demonstrated on a cementless hip, optimizing the implant for bone growth subject to wall thickness constraint
Implant prosthesis is the most appropriate treatment for dentition defect or dentition loss, which usually involves a surgical guide design process to decide the implant position. However, such design heavily relies on the subjective experiences of dentists. In this paper, a transformer-based Implant Position Regression Network, ImplantFormer, is proposed to automatically predict the implant position based on the oral CBCT data. We creatively propose to predict the implant position using the 2D axial view of the tooth crown area and fit a centerline of the implant to obtain the actual implant position at the tooth root. Convolutional stem and decoder are designed to coarsely extract image features before the operation of patch embedding and integrate multi-level feature maps for robust prediction, respectively. As both long-range relationship and local features are involved, our approach can better represent global information and achieves better location performance. Extensive experiments on a dental implant dataset through five-fold cross-validation demonstrated that the proposed ImplantFormer achieves superior performance than existing methods.
In traumatic medical emergencies, the patients heavily depend on cranioplasty - the craft of neurocranial repair using cranial implants. Despite the improvements made in recent years, the design of a patient-specific implant (PSI) is among the most complex, expensive, and least automated tasks in cranioplasty. Further research in this area is needed. Therefore, we created a prototype application with a graphical user interface (UI) specifically tailored for semi-automatic implant generation, where the users only need to perform high-level actions. A general outline of the proposed implant generation process involves setting an area of interest, aligning the templates, and then creating the implant in voxel space. Furthermore, we show that the alignment can be improved significantly, by only considering clipped geometry in the vicinity of the defect border. The software prototype will be open-sourced at https://github.com/3Descape/Cranial_Implant_Design
Spatially distributed peripheral nerve recordings can be used to reconstruct motor intention and improve natural control of prosthetics However, many existing clinical solutions rely on percutaneous wires to access peripheral nerves; these sites are prone to infection and motion-induced electrode degradation, preventing chronic use. To address the need for fully wireless neural recording systems, this paper presents DustNet: a spatially-distributed network of ultrasonically-powered neural recording implants capable of supporting up to 8 simultaneously recording nodes over a single ultrasound link. To enable high throughput multi-implant communication, DustNet implements a time-division multiple-access (TDMA) protocol with up to 16-level amplitude modulation of the ultrasound backscatter that achieves up to 4x higher data rates than traditional on-off keying methods. Each neural implant consists of a 0.7x0.7x0.7 mm$^3$ piezoceramic transducer, a 100 nF off-chip capacitor, and an IC mounted on a flexible PCB. The implant IC was fabricated in a 28nm CMOS process and occupies an area of 0.43 mm$^2$. System functionality was verified at 90mm depth in oil, achieving a maximum measured da
Breast implants are widely used after breast cancer resection and must be changed regularly to avoid a rupture. To date, there are no quantitative criteria to help this decision. The mechanical evolution of the gels and membranes of the implants is still under investigated, although it can lead to early rupture. In this study, 35 breast explants having been implanted in patients for up to 17 years were characterized by ex vivo measurements of their mechanical properties. Using Acoustic Radiation Force Impulse (ARFI) ultrasound elastography, an imaging method for non-destructive mechanical characterization, an increase in the stiffness of the explants has been observed. This increase was correlated with the implantation duration, primarily after 8 years of implantation. With an increase of the shear modulus of up to a factor of nearly 3, the loss of flexibility of the implants is likely to lead to a significant increase of their risk of rupture. A complementary analysis of the gel from the explants by mass spectrometry imaging (MSI) and liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) confirms the presence of metabolites of cholesterol originating from th