Accurately monitoring mental fatigue is critical for improving workplace safety and productivity. A recent study examined unobtrusively collected smartphone typing speed as a potential ambulatory proxy assessment of mental fatigue using data from the Intern Health Study (IHS). While population-level average typing speed patterns were found to be consistent with validated measures of mental fatigue, how these trajectories vary across participants and days may inform opportune moments for just-in-time interventions and remains an open question. Treating typing speed trajectories as sparsely observed functional data, we propose a novel sparse longitudinal functional principal component analysis (sparse LFPCA) method for decomposing variability and predicting individual curves. Specifically, sparse data are accommodated by casting covariance estimation as a structured penalized spline regression problem, enabling simultaneous estimation and smoothing of multiple covariance components while borrowing information across locations in the functional domain. Simulations show that sparse LFPCA (1) accurately estimates eigenfunctions and generates reasonable predictions for underlying curves,
The accelerometer has become an almost ubiquitous device, providing enormous opportunities in healthcare monitoring beyond step counting or other average energy estimates in 15-60 second epochs. Objective: To develop an open data set with associated open-source code for processing 50 Hz tri-axial accelerometry-based to classify patient activity levels and natural types of movement. Approach: Data were collected from 23 healthy subjects (16 males and seven females) aged between 23 and 62 years using an ambulatory device, which included a triaxial accelerometer and synchronous lead II equivalent ECG for an average of 26 minutes each. Participants followed a standardized activity routine involving five distinct activities: lying, sitting, standing, walking, and jogging. Two classifiers were constructed: a signal processing technique to distinguish between high and low activity levels and a convolutional neural network (CNN)-based approach to classify each of the five activities. Main results: The binary (high/low) activity classifier exhibited an F1 score of 0.79. The multi-class CNN-based classifier provided an F1 score of 0.83. The code for this analysis has been made available unde
Hypertension is a leading cause of morbidity and mortality worldwide. The ability to diagnose and treat hypertension in the ambulatory population is hindered by limited access and poor adherence to current methods of monitoring blood pressure (BP), specifically, cuff-based devices. Remote photoplethysmography (rPPG) evaluates an individual's pulse waveform through a standard camera without physical contact. Cameras are readily available to the majority of the global population via embedded technologies such as smartphones, thus rPPG is a scalable and promising non-invasive method of BP monitoring. The few studies investigating rPPG for BP measurement have excluded high-risk populations, including those with cardiovascular disease (CVD) or its risk factors, as well as subjects in active cardiac arrhythmia. The impact of arrhythmia, like atrial fibrillation, on the prediction of BP using rPPG is currently uncertain. We performed a study to better understand the relationship between rPPG and BP in a real-world sample of ambulatory patients from a cardiology clinic with established CVD or risk factors for CVD. We collected simultaneous rPPG, PPG, BP, ECG, and other vital signs data fro
Ambulatory blood pressure monitoring (ABPM) enables continuous measurement of blood pressure and heart rate over 24 hours and is increasingly used in clinical studies. However, ABPM data are often reduced to summary statistics, such as means or medians, which obscure temporal features like nocturnal dipping and individual chronotypes. Functional data analysis methods better capture these temporal dynamics but typically treat each ABPM measurement separately, limiting their ability to leverage correlations among matched measurements. In this work, we observe that aligning ABPM data along measurement type, time, and patient ID lends itself to a tensor representation--a multidimensional array. Although tensor learning has shown great potential in other fields, it has not been applied to ABPM data. Existing tensor learning approaches often lack temporal smoothing constraints, assume no missing data, and can be computationally demanding. To address these limitations, we propose a novel smooth tensor decomposition method that incorporates a temporal smoothing penalty and accommodates missing data. We also develop an automatic procedure for selecting the optimal smoothing parameter and te
Vision Language Models (VLMs) excel at visual question answering (VQA) but remain limited to snapshot vision, reasoning from static images. In contrast, embodied agents require ambulatory vision, actively moving to obtain more informative views. We introduce Visually Grounded Active View Selection (VG-AVS), a task that selects the most informative next viewpoint using only the visual information in the current image, without relying on scene memory or external knowledge. To support this task, we construct a synthetic dataset with automatically generated paired query-target views and question-answer prompts. We also propose a framework that fine-tunes pretrained VLMs through supervised fine-tuning (SFT) followed by RL-based policy optimization. Our approach achieves strong question answering performance based on viewpoint selection and generalizes robustly to unseen synthetic and real scenes. Furthermore, incorporating our learned VG-AVS framework into existing scene-exploration-based EQA systems improves downstream question-answering accuracy.
Chronic disease management and follow-up are vital for realizing sustained patient well-being and optimal health outcomes. Recent advancements in wearable sensing technologies, particularly wrist-worn devices, offer promising solutions for longitudinal patient follow-up by shifting from subjective, intermittent self-reporting to objective, continuous monitoring. However, collecting and analyzing wearable data presents unique challenges, such as data entry errors, non-wear periods, missing wearable data, and wearable artifacts. We therefore present an in-depth exploration of data analysis challenges tied to wrist-worn wearables and ambulatory label acquisition, using two real-world datasets (i.e., mBrain21 and ETRI lifelog2020). We introduce novel practical countermeasures, including participant compliance visualizations, interaction-triggered questionnaires to assess personal bias, and an optimized wearable non-wear detection pipeline. Further, we propose a visual analytics approach to validate processing pipelines using scalable tools such as tsflex and Plotly-Resampler. Lastly, we investigate the impact of missing wearable data on "window-of-interest" analysis methodologies. Prio
In many states, certificate-of-need (CON) laws prevent ambulatory surgical centers (ASCs) from entering the market or expanding their services. This paper estimates the causal effects of state ASC-CON law repeal on the accessibility of medical services statewide, as well as for rural areas. Our findings show that CON law repeals increase ASCs per capita by 44-47% statewide and 92-112% in rural areas. Repealing ASC-CON laws causes a continuous increase in ASCs per capita, an effect which levels off ten years after repeal. Contrary to the 'cream-skimming' hypothesis, we find no evidence that CON repeal is associated with hospital closures in rural areas. Rather, some regression models show that repeal is associated with fewer medical service reductions.
Over many decades, research is being attempted for the removal of noise in the ambulatory EEG. In this respect, an enormous number of research papers is published for identification of noise removal, It is difficult to present a detailed review of all these literature. Therefore, in this paper, an attempt has been made to review the detection and removal of an noise. More than 100 research papers have been discussed to discern the techniques for detecting and removal the ambulatory EEG. Further, the literature survey shows that the pattern recognition required to detect ambulatory method, eye open and close, varies with different conditions of EEG datasets. This is mainly due to the fact that EEG detected under different conditions has different characteristics. This is, in turn, necessitates the identification of pattern recognition technique to effectively distinguish EEG noise data from a various condition of EEG data.
This study investigates the potential of an ambulatory device that incorporates Large Language Models (LLMs) in cadence with other specialized ML models to assess anemia severity in sickle cell patients in real time. The device would rely on sensor data that measures angiogenic material levels to assess anemia severity, providing real-time information to patients and clinicians to reduce the frequency of vaso-occlusive crises because of the early detection of anemia severity, allowing for timely interventions and potentially reducing the likelihood of serious complications. The main challenges in developing such a device are the creation of a reliable non-invasive tool for angiogenic level assessment, a biophysics model and the practical consideration of an LLM communicating with emergency personnel on behalf of an incapacitated patient. A possible system is proposed, and the limitations of this approach are discussed.
The continued integration of technology into all aspects of society stresses the need to identify and understand the risk associated with assimilating new technologies. This necessity is heightened when technology is used for medical purposes like ambulatory devices that monitor a patient's vital signs. This integration creates environments that are conducive to malicious activities. The potential impact presents new challenges for the medical community. Hence, this research presents attack graph modeling as a viable solution to identifying vulnerabilities, assessing risk, and forming mitigation strategies to defend ambulatory medical devices from attackers. Common and frequent vulnerabilities and attack strategies related to the various aspects of ambulatory devices, including Bluetooth enabled sensors and Android applications are identified in the literature. Based on this analysis, this research presents an attack graph modeling example on a theoretical device that highlights vulnerabilities and mitigation strategies to consider when designing ambulatory devices with similar components.
In healthcare, detecting stress and enabling individuals to monitor their mental health and wellbeing is challenging. Advancements in wearable technology now enable continuous physiological data collection. This data can provide insights into mental health and behavioural states through psychophysiological analysis. However, automated analysis is required to provide timely results due to the quantity of data collected. Machine learning has shown efficacy in providing an automated classification of physiological data for health applications in controlled laboratory environments. Ambulatory uncontrolled environments, however, provide additional challenges requiring further modelling to overcome. This work empirically assesses several approaches utilising machine learning classifiers to detect stress using physiological data recorded in an ambulatory setting with self-reported stress annotations. A subset of the training portion SMILE dataset enables the evaluation of approaches before submission. The optimal stress detection approach achieves 90.77% classification accuracy, 91.24 F1-Score, 90.42 Sensitivity and 91.08 Specificity, utilising an ExtraTrees classifier and feature imputat
Ambulatory cardiovascular (CV) measurements provide valuable insights into individuals' health conditions in "real-life," everyday settings. Current methods of modeling ambulatory CV data do not consider the dynamic characteristics of the full data set and their relationships with covariates such as caffeine use and stress. We propose a stochastic differential equation (SDE) in the form of a dual nonlinear Ornstein--Uhlenbeck (OU) model with person-specific covariates to capture the morning surge and nighttime dipping dynamics of ambulatory CV data. To circumvent the data analytic constraint that empirical measurements are typically collected at irregular and much larger time intervals than those evaluated in simulation studies of SDEs, we adopt a Bayesian approach with a regularized Brownian Bridge sampler (RBBS) and an efficient multiresolution (MR) algorithm to fit the proposed SDE. The MR algorithm can produce more efficient MCMC samples that is crucial for valid parameter estimation and inference. Using this model and algorithm to data from the Duke Behavioral Investigation of Hypertension Study, results indicate that age, caffeine intake, gender and race have effects on disti
Continuous ambulatory monitoring of peripheral vascular perfusion could enable earlier detection of vascular dysfunction in individuals with diabetes mellitus and more timely management of cardiovascular disease. Clinical imaging modalities provide high-fidelity vascular information but are impractical for ambulatory use, whereas most wearable devices are limited to single-modality sensing and do not provide imaging. Electrical bioimpedance has the potential to bridge this gap by enabling rapid spatial and temporal imaging while remaining sensitive to hemodynamic changes. Here, we introduce a wearable ring with 8 electrodes and 32-channel bioimpedance sensing for finger blood flow imaging. In 96 healthy participants measured at rest and during autonomic maneuvers, we resolve conductivity images in the digital arteries associated with pulsatile blood flow and train neural network models for continuous cuffless blood pressure waveform estimation. We demonstrate the feasibility of bioimpedance imaging in a ring form factor, supporting its potential for ambulatory cuffless hemodynamic monitoring.
This study presents AI-HEART, a cloud-based information system for managing and analysing long-duration ambulatory electrocardiogram (ECG) recordings and supporting clinician decision-making. The platform operationalises an end-to-end pipeline that ingests multi-day three-lead ECGs, normalises inputs, performs signal preprocessing, and applies dedicated deep neural networks for wave delineation, noise/quality detection, and beat- and rhythm-level multi-class arrhythmia classification. To address class imbalance and real-world signal variability, model development combines large clinically annotated datasets with expert-in-the-loop curation and generative augmentation for under-represented rhythms. Empirical evaluation on three-lead ambulatory ECG data shows that delineation accuracy is sufficient for automated interval measurement, noise detection reliably flags poor-quality segments, and arrhythmia classification achieves high specificity with clinically useful macro-averaged performance across common and rarer rhythms. Beyond predictive accuracy, AI-HEART provides a scalable deployment approach for integrating AI into routine ECG services, enabling traceable outputs, audit-friend
The increasing prevalence of chronic diseases poses a significant challenge to global efforts to alleviate poverty, promote health equity, and control healthcare costs. This study adopts a structural approach to explore how patients manage chronic diseases by making trade-offs between inpatient care and ambulatory care outpatient services. Specifically, it investigates whether disadvantaged populations make distinct trade-offs compared to the general population and examines the impact of anti-poverty programs that reduce inpatient cost-sharing. Using health insurance claims data from a rural county in China, the study reveals that disadvantaged individuals tend to avoid ambulatory care unless it substantially lowers medical expenses. In contrast, the general population is more likely to prioritize ambulatory care, even at higher costs, to prevent disease progression. The findings also indicate that current anti-poverty insurance policies, which focus predominantly on hospitalization, inadvertently decrease ambulatory care usage by 23\%, resulting in increased healthcare costs and a 46.2\% decline in patient welfare. Counterfactual analysis suggests that reducing cost-sharing for am
Body area networks (BANs) require lightweight session key establishment, yet public key exchange imposes computation and energy costs that exceed the budgets of deeply constrained wearable nodes. This brief presents HHK, a hardware-oriented cross-location photoplethysmography (PPG) key generation architecture for BANs. The proposed datapath extracts inter-beat intervals (IBIs) from green-light PPG at multiple body sites, aligns beat timestamps across locations, applies Gray-coded equal-frequency quantization, and employs a rate-1/3 polar code fuzzy commitment (N=128, K=42) to reconcile residual timing mismatches. Post-implementation synthesis on a Xilinx XC7Z020 maps the complete datapath to 18,760 lookup tables and 20,971 flip-flops with no multipliers or embedded memories, giving 48 uJ per key generation event and 0.4 uW average power over a 120-second acquisition window. Validation across 16 participants from a real ambulatory dataset (216 hours; head, wrist, and ankle) yields 86.0-90.1% raw IBI bit agreement and 51.3-69.8% key agreement. To the best of our knowledge, HHK is the first synthesizable register-transfer level (RTL) key generation architecture for BANs validated acro
Background and Objective: Continuous wearable electrocardiogram (ECG) monitoring is increasingly used for ambulatory arrhythmia surveillance, yet forecasting impending atrial fibrillation (AF) is challenged by inter-patient ECG variability. This study investigated whether personalizing a global model via fine-tuning on an individual's ECG signals improves short-term forecasting of impending AF. Methods: A global model trained on the ICENTIA11K dataset was compared against personalized models fine-tuned across three cohorts: ICENTIA11K, IRIDIA-AF, and MobiCARE. Following preprocessing, models processed 60-second ECG segments for a five-minute forecast horizon. We evaluated the impact of adaptation data volume and analyzed ECG features, such as heart rate and RMSSD. Results: Personalized models significantly outperformed the global model, achieving AUROCs of 0.711 vs. 0.614 in ICENTIA11K and 0.686 vs. 0.585 in MobiCARE. Personalization benefits increased with the amount of patient-specific fine-tuning data. While the global model's accuracy rose as AF onset approached, personalized models in the two external cohorts exhibited distinct temporal dynamics, which may indicate the capture
Ambulatory neck-surface acceleration enables non-invasive monitoring of vocal hyperfunction, yet robust biomarkers for its subtypes remain limited. This study investigates the NeckVibe Challenge dataset to distinguish phonotraumatic (PVH) and non-phonotraumatic (NPVH) from healthy controls. We propose a hierarchical feature engineering framework comprising: (i) static, (ii) dynamic, (iii) ratio-based, (iv) coupling features capturing source filter interactions. While univariate statistical analysis shows strong separability for PVH but limited significance for NPVH, our machine learning pipeline, tailored for high-dimensional feature integration, identifies that coupling features are crucial for both tasks. We achieve an AUC of 0.891 for PVH and 0.728 for NPVH, suggesting that while PVH is near-linearly separable, NPVH discrimination benefits from modeling non-linear feature interactions.
Vocal hyperfunction (VH) is a prevalent voice disorder whose ambulatory detection remains challenging despite extensive daily voice data. Prior approaches capture week-long neck-surface accelerometer recordings but collapse them into fixed-length subject-level feature vectors, discarding within-day temporal dynamics encoding nuanced voicing feature interactions. We introduce a novel hybrid architecture combining gradient-boosted trees on day-level distributional features with a CNN-based multiple instance learning (MIL) framework that preserves and learns from from temporal dynamics throughout each day. On the held-out test set, our model exceeds the challenge baselines (AUC: 0.82 PVH, 0.77 NPVH), achieving AUCs of 0.879 for PVH (Rank 5) and 0.848 for NPVH (Rank 3), while also providing insights into clinically relevant information about both pathologies.
Objective: The Daily Phonotrauma Index (DPI) can quantify pathophysiological mechanisms associated with daily voice use in individuals with phonotraumatic vocal hyperfunction (PVH). Since DPI was developed based on week-long ambulatory voice monitoring, this study investigated if DPI can achieve comparable performance using (1) short laboratory speech tasks and (2) fewer than seven days of ambulatory data. Method: An ambulatory voice monitoring system recorded the vocal function/behavior of 134 females with PVH and vocally healthy matched controls in two different conditions. In the lab, the participants read the first paragraph of the Rainbow Passage and produced spontaneous speech (in-lab data). They were then monitored for seven days (in-field data). Separate DPI models were trained from in-lab and in-field data using the standard deviation of the difference between the magnitude of the first two harmonics (H1-H2) and the skewness of neck-surface acceleration magnitude. First, 10-fold cross-validation evaluated classification performance of in-lab and in-field DPIs. Second, the effect of the number of ambulatory monitoring days on the accuracy of in-field DPI classification was