Strabismus affects 2-4% of the population, yet individuals recovering from corrective surgery lack accessible tools for monitoring eye alignment. Dichoptic therapies require active engagement & clinical supervision, limiting their adoption for passive self-awareness. We present GazeFlow, a browser-based self-monitoring system that uses a personalized temporal autoencoder to detect eye drift patterns from webcam-based gaze tracking & provides ambient audio feedback. Unlike alert-based systems, GazeFlow operates according to calm computing principles, morphing musical parameters in proportion to drift severity while remaining in peripheral awareness. We address the challenges of inter-individual variability & domain transfer (1000Hz research to 30Hz webcam) by introducing Binocular Temporal-Frequency Disentanglement (BTFD), Contrastive Biometric Pre-training (CBP), & Gaze-MAML. We validate our approach on the GazeBase dataset (N=50) achieving F1=0.84 for drift detection, & conduct a preliminary user study (N=6) with participants having intermittent strabismus. Participants reported increased awareness of their eye behaviour (M=5.8/7) & preference for ambient f
Purpose: Up to 4% of adults will develop strabismus in their lifetime. The most common surgical intervention involves adjusting the length of one or more extraocular muscles to correct the angular deviation. This correction depends on surgical expertise and statistical reference tables, which often fail to yield optimal results for patients with atypical eye morphology. Our work proposes a physics-based modeling approach to personalized surgical planning, accounting for patient-specific eye anatomy. Methods: We built a physics-based simulator of the eye and its muscles, incorporating patient-specific geometry and Hill-type muscle biomechanics. We solve an optimization problem to find the surgical dosage that minimizes angular deviation. The model is implemented as a fully differentiable simulation, enabling efficient optimization. We validated the framework by comparing its predictions with standard surgical tables for emmetropic eyes before applying it to anatomically atypical virtual patients. Results: Our model's predictions for emmetropic eyes were first validated, demonstrating a strong fit with standard surgical tables. More importantly, for high-myopia models, the framework
Ocular-induced abnormal head posture (AHP) is a compensatory mechanism that arises from ocular misalignment conditions, such as strabismus, enabling patients to reduce diplopia and preserve binocular vision. Early diagnosis minimizes morbidity and secondary complications such as facial asymmetry; however, current clinical assessments remain largely subjective and are further complicated by incomplete medical records. This study addresses both challenges through two complementary deep learning frameworks. First, AHP-CADNet is a multi-level attention fusion framework for automated diagnosis that integrates ocular landmarks, head pose features, and structured clinical attributes to generate interpretable predictions. Second, a curriculum learning-based imputation framework is designed to mitigate missing data by progressively leveraging structured variables and unstructured clinical notes to enhance diagnostic robustness under realistic data conditions. Evaluation on the PoseGaze-AHP dataset demonstrates robust diagnostic performance. AHP-CADNet achieves 96.9-99.0 percent accuracy across classification tasks and low prediction errors for continuous variables, with MAE ranging from 0.1
PURPOSE OF REVIEW: Despite the impressive results of recent artificial intelligence (AI) applications to general ophthalmology, comparatively less progress has been made toward solving problems in pediatric ophthalmology using similar techniques. This article discusses the unique needs of pediatric ophthalmology patients and how AI techniques can address these challenges, surveys recent applications of AI to pediatric ophthalmology, and discusses future directions in the field. RECENT FINDINGS: The most significant advances involve the automated detection of retinopathy of prematurity (ROP), yielding results that rival experts. Machine learning (ML) has also been successfully applied to the classification of pediatric cataracts, prediction of post-operative complications following cataract surgery, detection of strabismus and refractive error, prediction of future high myopia, and diagnosis of reading disability via eye tracking. In addition, ML techniques have been used for the study of visual development, vessel segmentation in pediatric fundus images, and ophthalmic image synthesis. SUMMARY: AI applications could significantly benefit clinical care for pediatric ophthalmology pa
Optokinetic nystagmus (OKN) is an involuntary eye movement responsible for stabilizing retinal images in the presence of relative motion between an observer and the environment. Fully understanding the development of optokinetic nystagmus requires a neurally plausible computational model that accounts for the neural development and the behavior. To date, work in this area has been limited. We propose a neurally plausible framework for the joint development of disparity and motion tuning in the visual cortex, the optokinetic and vergence eye movements. This framework models the joint emergence of both perception and behavior, and accounts for the importance of the development of normal vergence control and binocular vision in achieving normal monocular OKN (mOKN) behaviors. Because the model includes behavior, we can simulate the same perturbations as performed in past experiments, such as artificially induced strabismus. The proposed model agrees both qualitatively and quantitatively with a number of findings from the literature on both binocular vision as well as the optokinetic reflex. Finally, our model also makes quantitative predictions about the OKN behavior using the same me