Vascular segmentation in medical images is crucial for disease diagnosis and surgical navigation. However, the segmented vascular structure is often discontinuous due to its slender nature and inadequate prior modeling. In this paper, we propose a novel Serpentine Window Mamba (SWinMamba) to achieve accurate vascular segmentation. The proposed SWinMamba innovatively models the continuity of slender vascular structures by incorporating serpentine window sequences into bidirectional state space models. The serpentine window sequences enable efficient feature capturing by adaptively guiding global visual context modeling to the vascular structure. Specifically, the Serpentine Window Tokenizer (SWToken) adaptively splits the input image using overlapping serpentine window sequences, enabling flexible receptive fields (RFs) for vascular structure modeling. The Bidirectional Aggregation Module (BAM) integrates coherent local features in the RFs for vascular continuity representation. In addition, dual-domain learning with Spatial-Frequency Fusion Unit (SFFU) is designed to enhance the feature representation of vascular structure. Extensive experiments on three challenging datasets demons
The segmentation of 2D vascular structures via deep learning holds significant clinical value but is hindered by the scarcity of annotated data, severely limiting its widespread application. Developing a universal few-shot vascular segmentation model is highly desirable, yet remains challenging due to the need for extensive training and the inherent complexities of vascular imaging. In this work, we propose UniVG (Generative Data-engine Foundation Model for Universal Few-shot 2D Vascular Image Segmentation), a novel approach that learns the compositionality of vascular images and constructing a generative foundation model for robust vascular segmentation. UniVG enables the synthesis and learning of diverse and realistic vascular images through two key innovations: 1) Compositional learning for flexible and diverse vascular synthesis: It decomposes and recombines vascular structures with varying morphological features and diverse foreground-background configurations to generate richly diverse synthetic image-label pairs. 2) Few-shot generative adaptation for transferable segmentation: It fine-tunes pre-trained models with minimal annotated data to bridge the gap between synthetic an
MR vascular Fingerprinting proposes to use the MR Fingerprinting framework to quantitatively and simultaneously map several microvascular characteristics at a sub-voxel scale. The initial implementation assessed the local blood oxygenation saturation (SO 2), blood volume fraction (BVf) and vessel averaged radius (R) in humans and rodent brains using simple 2D representations of the vascular network during dictionary generation. In order to improve the results and possibly extend the approach to pathological environments and other biomarkers, we propose in this study to use 3D realistic vascular geometries in the numerical simulations. 28,000 different synthetic voxels containing vascular networks segmented from whole brain healthy mice microscopy images were created. A Bayesian-based regression model was used for map reconstruction. We show on 8 healthy and 9 tumor bearing rats that realistic vascular representations yield microvascular estimates in better agreement with the literature than 2D or 3D cylindrical models. Furthermore, tumoral blood oxygenation estimates obtained with the proposed approach are the only ones correlating with in vivo optic-fiber measurements performed in
With the advent of robot-assisted surgery, the role of data-driven approaches to integrate statistics and machine learning is growing rapidly with prominent interests in objective surgical skill assessment. However, most existing work requires translating robot motion kinematics into intermediate features or gesture segments that are expensive to extract, lack efficiency, and require significant domain-specific knowledge. We propose an analytical deep learning framework for skill assessment in surgical training. A deep convolutional neural network is implemented to map multivariate time series data of the motion kinematics to individual skill levels. We perform experiments on the public minimally invasive surgical robotic dataset, JHU-ISI Gesture and Skill Assessment Working Set (JIGSAWS). Our proposed learning model achieved a competitive accuracy of 92.5%, 95.4%, and 91.3%, in the standard training tasks: Suturing, Needle-passing, and Knot-tying, respectively. Without the need of engineered features or carefully-tuned gesture segmentation, our model can successfully decode skill information from raw motion profiles via end-to-end learning. Meanwhile, the proposed model is able to
Cerebral blood flow regulation is critical for brain function, and its disruption is implicated in various neurological disorders. Many existing models do not fully capture the complex, multiscale interactions among neuronal activity, astrocytic signaling, and vascular dynamics--especially in key brainstem regions. In this work, we present a 3D-1D-0D multiscale computational framework for modeling the neuro-glial-vascular unit (NGVU) in the dorsal vagal complex (DVC). Our approach integrates a quadripartite synapse model--which represents the interplay among excitatory and inhibitory neurons, astrocytes, and vascular smooth muscle cells--with a hierarchical description of vascular dynamics that couples a three-dimensional microcirculatory network with a one-dimensional macrocirculatory representation and a zero-dimensional synaptic component. By linking neuronal spiking, astrocytic calcium and gliotransmitter signaling, and vascular tone regulation, our model reproduces key features of functional hyperemia and elucidates the feedback loops that help maintain cerebral blood flow. Simulation results demonstrate that neurotransmitter release triggers astrocytic responses that modulate
Autonomous microrobots in blood vessels could enable minimally invasive therapies, but navigation is challenged by dense, moving obstacles. We propose a real-time path planning framework that couples an analytic geometry global planner (AGP) with two reactive local escape controllers, one based on rules and one based on reinforcement learning, to handle sudden moving obstacles. Using real-time imaging, the system estimates the positions of the microrobot, obstacles, and targets and computes collision-free motions. In simulation, AGP yields shorter paths and faster planning than weighted A* (WA*), particle swarm optimization (PSO), and rapidly exploring random trees (RRT), while maintaining feasibility and determinism. We extend AGP from 2D to 3D without loss of speed. In both simulations and experiments, the combined global planner and local controllers reliably avoid moving obstacles and reach targets. The average planning time is 40 ms per frame, compatible with 25 fps image acquisition and real-time closed-loop control. These results advance autonomous microrobot navigation and targeted drug delivery in vascular environments.
The recent Segment Anything Model (SAM) 2 has demonstrated remarkable foundational competence in semantic segmentation, with its memory mechanism and mask decoder further addressing challenges in video tracking and object occlusion, thereby achieving superior results in interactive segmentation for both images and videos. Building upon our previous empirical studies, we further explore the zero-shot segmentation performance of SAM 2 in robot-assisted surgery based on prompts, alongside its robustness against real-world corruption. For static images, we employ two forms of prompts: 1-point and bounding box, while for video sequences, the 1-point prompt is applied to the initial frame. Through extensive experimentation on the MICCAI EndoVis 2017 and EndoVis 2018 benchmarks, SAM 2, when utilizing bounding box prompts, outperforms state-of-the-art (SOTA) methods in comparative evaluations. The results with point prompts also exhibit a substantial enhancement over SAM's capabilities, nearing or even surpassing existing unprompted SOTA methodologies. Besides, SAM 2 demonstrates improved inference speed and less performance degradation against various image corruption. Although slightly u
The diffusion of minimally invasive, endovascular interventions motivates the development of visualization methods for complex vascular networks. We propose a planar representation of blood vessel trees which preserves the properties that are most relevant to catheter navigation: topology, length and curvature. Taking as input a three-dimensional digital angiography, our algorithm produces a faithful two-dimensional map of the patient's vessels within a few seconds. To this end, we propose optimized implementations of standard morphological filters and a new recursive embedding algorithm that preserves the global orientation of the vascular network. We showcase our method on peroperative images of the brain, pelvic and knee artery networks. On the clinical side, our method simplifies the choice of devices prior to and during the intervention. This lowers the risk of failure during navigation or device deployment and may help to reduce the gap between expert and common intervention centers. From a research perspective, our method simulates the cadaveric display of artery trees from anatomical dissections. This opens the door to large population studies on the branching patterns and
Vessel dynamics simulation is vital in studying the relationship between geometry and vascular disease progression. Reliable dynamics simulation relies on high-quality vascular meshes. Most of the existing mesh generation methods highly depend on manual annotation, which is time-consuming and laborious, usually facing challenges such as branch merging and vessel disconnection. This will hinder vessel dynamics simulation, especially for the population study. To address this issue, we propose a deep learning-based method, dubbed as DVasMesh to directly generate structured hexahedral vascular meshes from vascular images. Our contributions are threefold. First, we propose to formally formulate each vertex of the vascular graph by a four-element vector, including coordinates of the centerline point and the radius. Second, a vectorized graph template is employed to guide DVasMesh to estimate the vascular graph. Specifically, we introduce a sampling operator, which samples the extracted features of the vascular image (by a segmentation network) according to the vertices in the template graph. Third, we employ a graph convolution network (GCN) and take the sampled features as nodes to esti
Concept erasure in text-to-image diffusion models is crucial for mitigating harmful content, yet existing methods often compromise generative quality. We introduce Semantic Surgery, a novel training-free, zero-shot framework for concept erasure that operates directly on text embeddings before the diffusion process. It dynamically estimates the presence of target concepts in a prompt and performs a calibrated vector subtraction to neutralize their influence at the source, enhancing both erasure completeness and locality. The framework includes a Co-Occurrence Encoding module for robust multi-concept erasure and a visual feedback loop to address latent concept persistence. As a training-free method, Semantic Surgery adapts dynamically to each prompt, ensuring precise interventions. Extensive experiments on object, explicit content, artistic style, and multi-celebrity erasure tasks show our method significantly outperforms state-of-the-art approaches. We achieve superior completeness and robustness while preserving locality and image quality (e.g., 93.58 H-score in object erasure, reducing explicit content to just 1 instance, and 8.09 H_a in style erasure with no quality degradation).
Vascular tracking of angiographic image sequences is one of the most clinically important tasks in the diagnostic assessment and interventional guidance of cardiac disease. However, this task can be challenging to accomplish because of unsatisfactory angiography image quality and complex vascular structures. Thus, this study proposed a new greedy graph search-based method for vascular tracking. Each vascular branch is separated from the vasculature and is tracked independently. Then, all branches are combined using topology optimization, thereby resulting in complete vasculature tracking. A gray-based image registration method was applied to determine the tracking range, and the deformation field between two consecutive frames was calculated. The vascular branch was described using a vascular centerline extraction method with multi-probability fusion-based topology optimization. We introduce an undirected acyclic graph establishment technique. A greedy search method was proposed to acquire all possible paths in the graph that might match the tracked vascular branch. The final tracking result was selected by branch matching using dynamic time warping with a DAISY descriptor. The sol
This paper develops a new vascular respiratory motion compensation algorithm, Motion-Related Compensation (MRC), to conduct vascular respiratory motion compensation by extrapolating the correlation between invisible vascular and visible non-vascular. Robot-assisted vascular intervention can significantly reduce the radiation exposure of surgeons. In robot-assisted image-guided intervention, blood vessels are constantly moving/deforming due to respiration, and they are invisible in the X-ray images unless contrast agents are injected. The vascular respiratory motion compensation technique predicts 2D vascular roadmaps in live X-ray images. When blood vessels are visible after contrast agents injection, vascular respiratory motion compensation is conducted based on the sparse Lucas-Kanade feature tracker. An MRC model is trained to learn the correlation between vascular and non-vascular motions. During the intervention, the invisible blood vessels are predicted with visible tissues and the trained MRC model. Moreover, a Gaussian-based outlier filter is adopted for refinement. Experiments on in-vivo data sets show that the proposed method can yield vascular respiratory motion compensa
Accurate identification of brain function is necessary to understand the neurobiology of cognitive ageing, and thereby promote well-being across the lifespan. A common tool used to investigate neurocognitive ageing is functional magnetic resonance imaging (fMRI). However, although fMRI data are often interpreted in terms of neuronal activity, the blood-oxygen-level-dependent (BOLD) signal measured by fMRI includes contributions of both vascular and neuronal factors, which change differentially with age. While some studies investigate vascular ageing factors, the results of these studies are not well known within the field of neurocognitive ageing and therefore vascular confounds in neurocognitive fMRI studies are common. In contrast to over 10,000 BOLD-fMRI papers on ageing, fewer than 20 have applied techniques to correct for vascular effects. However, neurovascular ageing is not only a confound in fMRI, but an important feature in its own right, to be assessed alongside measures of neuronal ageing. We review current approaches to dissociate neuronal and vascular components of BOLD-fMRI of regional activity and functional connectivity. We highlight emerging evidence that vascular
Materials science has a significant impact on society and its quality of life, e.g., through the development of safer, more durable, more economical, environmentally friendly, and sustainable materials. Visual computing in materials science integrates computer science disciplines from image processing, visualization, computer graphics, pattern recognition, computer vision, virtual and augmented reality, machine learning, to human-computer interaction, to support the acquisition, analysis, and synthesis of (visual) materials science data with computer resources. Therefore, visual computing may provide fundamentally new insights into materials science problems by facilitating the understanding, discovery, design, and usage of complex material systems. This seminar is considered as a follow-up of the Dagstuhl Seminar 19151 Visual Computing in Materials Sciences, held in April 2019. Since then, the field has kept evolving and many novel challenges have emerged, with regard to more traditional topics in visual computing, such as topology analysis or image processing and analysis, to recently emerging topics, such as uncertainty and ensemble analysis, and to the integration of new resear
The cerebrovascular tree is a complex anatomical structure that plays a crucial role in the brain irrigation. A precise identification of the bifurcations in the vascular network is essential for understanding various cerebral pathologies. Traditional methods often require manual intervention and are sensitive to variations in data quality. In recent years, deep learning techniques, and particularly autoencoders, have shown promising performances for feature extraction and pattern recognition in a variety of domains. In this paper, we propose two novel approaches for vascular bifurcation identification based respectiveley on Autoencoder and geometrical features. The performance and effectiveness of each method in terms of classification of vascular bifurcations using medical imaging data is presented. The evaluation was performed on a sample database composed of 91 TOF-MRA, using various evaluation measures, including accuracy, F1 score and confusion matrix.
For a nullhomologous Legendrian knot in a closed contact 3-manifold Y we consider a contact structure obtained by positive rational contact surgery. We prove that in this situation the Heegaard Floer contact invariant of Y is mapped by a surgery cobordism to the contact invariant of the result of contact surgery. In addition we characterize the spin-c structure on the cobordism that induces the relevant map. As a consequence we determine necessary and sufficient conditions for the nonvanishing of the contact invariant after rational surgery when Y is the standard 3-sphere, generalizing previous results of Lisca-Stipsicz and Golla. In fact our methods allow direct calculation of the contact invariant in terms of the rational surgery mapping cone of Ozsváth and Szabó. The proof involves a construction called reducible open book surgery, which reduces in special cases to the capping-off construction studied by Baldwin.
The analysis of biological networks encompasses a wide variety of fields from genomic research of protein-protein interaction networks, to the physiological study of biologically optimized tree-like vascular networks. It is certain that different biological networks have different optimization criteria and we are interested in those networks optimized for fluid transport within the circulatory system. Many theories currently exist. For instance, distributive vascular geometry data is typically consistent with a theoretical model that requires simultaneous minimization of both the power loss of laminar flow and a cost function proportional to the total volume of material needed to maintain the system (Murray's law). However, how this optimized system breaks down (or is altered) due to disease has yet to be characterized in detail in terms of branching geometry and geometric interrelationships. This is important for understanding how vasculature remodels under changes of functional demands. For instance, in polycystic kidney disease (PKD), drastic cyst development may lead to a significant alteration of the vascular geometry (or vascular changes may be a preceding event). Understandi
The attrition of women in academic careers is a major concern, particularly in Science, Technology, Engineering, and Mathematics subjects. One factor that can contribute to the attrition is the lack of visible role models for women in academia. At early career stages, the behaviour of the local community may play a formative role in identifying ingroup role models, shaping women's impressions of whether or not they can be successful in academia. One common and formative setting to observe role models is the local departmental academic seminar, talk, or presentation. We thus quantified women's visibility through the question-asking behaviour of academics at seminars using observations and an online survey. From the survey responses of over 600 academics in 20 countries, we found that women reported asking fewer questions after seminars compared to men. This impression was supported by observational data from almost 250 seminars in 10 countries: women audience members asked absolutely and proportionally fewer questions than male audience members. When asked why they did not ask questions when they wanted to, women, more than men, endorsed internal factors (e.g., not working up the ne
Purpose: Interventions at the otobasis operate in the narrow region of the temporal bone where several highly sensitive organs define obstacles with minimal clearance for surgical instruments. Nonlinear trajectories for potential minimally-invasive interventions can provide larger distances to risk structures and optimized orientations of surgical instruments, thus improving clinical outcomes when compared to existing linear approaches. In this paper, we present fast and accurate planning methods for such nonlinear access paths. Methods: We define a specific motion planning problem in SE(3) = R3 x SO(3) with notable constraints in computation time and goal pose that reflect the requirements of temporal bone surgery.We then present k-RRT-Connect: two suitable motion planners based on bidirectional Rapidly-exploring Random Trees (RRT) to solve this problem efficiently. Results: The benefits of k-RRT-Connect are demonstrated on real CT data of patients. Their general performance is shown on a large set of realistic synthetic anatomies. We also show that these new algorithms outperform state of the art methods based on circular arcs or Bezier-Splines when applied to this specific probl
Ultrasound imaging plays an important role in the diagnosis of vascular lesions. Accurate segmentation of the vascular wall is important for the prevention, diagnosis and treatment of vascular diseases. However, existing methods have inaccurate localization of the vascular wall boundary. Segmentation errors occur in discontinuous vascular wall boundaries and dark boundaries. To overcome these problems, we propose a new boundary-delineation network (BDNet). We use the boundary refinement module to re-delineate the boundary of the vascular wall to obtain the correct boundary location. We designed the feature extraction module to extract and fuse multi-scale features and different receptive field features to solve the problem of dark boundaries and discontinuous boundaries. We use a new loss function to optimize the model. The interference of class imbalance on model optimization is prevented to obtain finer and smoother boundaries. Finally, to facilitate clinical applications, we design the model to be lightweight. Experimental results show that our model achieves the best segmentation results and significantly reduces memory consumption compared to existing models for the dataset.