Poor adaptation of orbital implants remains a major contributor to postoperative complications and revision surgery. Although preformed orbital plates are widely used to reduce cost and operative time compared with customized implants, surgeons currently lack publicly available tools and standardized metrics to quantitatively compare plate fit across vendors, sizes, and patient anatomy. We developed SlicerOrbitSurgerySim, an open-source extension for the 3D Slicer platform that enables interactive virtual registration, evaluation, and comparison of multiple preformed orbital plates in a patient-specific virtual planning environment. The software generates reproducible quantitative plate-to-orbit distance metrics and visualization tools that support both patient-specific planning and population-level statistical analysis of plate adaptability. By facilitating objective comparison of implant designs and placement strategies, this tool aims to improve preoperative decision-making, reduce intraoperative plate modification, and promote collaborative research and surgical education. Pilot studies, sample datasets, and detailed tutorials are provided to support testing, transparency, and
We use a 1030 nm laser with 7 ps pulse duration and average power up to 100 W to ablate pyramid-shape subwavelength structures (SWS) on alumina and sapphire. The SWS give an effective and cryogenically robust anti-reflection coating in the millimeter-wave band. We demonstrate average ablation rate of up to 34 mm$^3$/min and 20 mm$^3$/min for structure heights of 900 $μ$m and 750 $μ$m on alumina and sapphire, respectively. These rates are a factor of 34 and 9 higher than reported previously on similar structures. We propose a model that relates structure height to cumulative laser fluence. The model depends on the absorption length $δ$, which is assumed to depend on peak fluence, and on the threshold fluence $φ_{th}$. Using a best-fit procedure we find an average $δ= 630$ nm and 650 nm, and $φ_{th} = 2.0^{+0.5}_{-0.5}$ J/cm$^2$ and $2.3^{+0.1}_{-0.1}$ J/cm$^2$ for alumina and sapphire, respectively, for peak fluence values between 30 and 70 J/cm$^{2}$. With the best fit values, the model and data values for cumulative fluence agree to within 10%. Given inputs for $δ$ and $φ_{th}$ the model is used to predict average ablation rates as a function of SWS height and average laser power.
Digital lasers control the laser beam by dynamically updating the phase patterns of the spatial light modulator (SLM) within the laser cavity. Due to the presence of nonlinear effects, such as mode competition and gain saturation in digital laser systems, it is often necessary to rely on specifically manually tailored approach or iteration processes to find suitable loaded phases in Digital lasers. This study proposes a model based on Conditional Generative Adversarial Networks (cGAN) and a modified U-Net architecture, with designed loss functions to inverse design the loaded phases. In this work, we employ deep neural networks to learn the nonlinear effects in simulated L-shape digital lasers, enabling the prediction of SLM-loaded phases for both analytical and non-analytical arbitrary structured light fields. The results demonstrate superior performance on non-analytical light fields compared to the current methods in L-shape Digital lasers. Furthermore, a transfer learning strategy is introduced, allowing knowledge obtained from one class of structured beams to be effectively reused for another, thereby enhancing generalization and improving performance under limited training da
Deep neural networks power most recent successes of artificial intelligence, spanning from self-driving cars to computer aided diagnosis in radiology and pathology. The high-stake data intensive process of surgery could highly benefit from such computational methods. However, surgeons and computer scientists should partner to develop and assess deep learning applications of value to patients and healthcare systems. This chapter and the accompanying hands-on material were designed for surgeons willing to understand the intuitions behind neural networks, become familiar with deep learning concepts and tasks, grasp what implementing a deep learning model in surgery means, and finally appreciate the specific challenges and limitations of deep neural networks in surgery. For the associated hands-on material, please see https://github.com/CAMMA-public/ai4surgery.
Background Analyzing kinematic and video data can help identify potentially erroneous motions that lead to sub-optimal surgeon performance and safety-critical events in robot-assisted surgery. Methods We develop a rubric for identifying task and gesture-specific Executional and Procedural errors and evaluate dry-lab demonstrations of Suturing and Needle Passing tasks from the JIGSAWS dataset. We characterize erroneous parts of demonstrations by labeling video data, and use distribution similarity analysis and trajectory averaging on kinematic data to identify parameters that distinguish erroneous gestures. Results Executional error frequency varies by task and gesture, and correlates with skill level. Some predominant error modes in each gesture are distinguishable by analyzing error-specific kinematic parameters. Procedural errors could lead to lower performance scores and increased demonstration times but also depend on surgical style. Conclusions This study provides insights into context-dependent errors that can be used to design automated error detection mechanisms and improve training and skill assessment.
This paper presents a comprehensive technical overview of the Linac Coherent Light Source II (LCLS-II) photoinjector laser system, its first and foremost component. The LCLS-II photoinjector laser system serves as an upgrade to the original LCLS at SLAC National Accelerator Laboratory. This advanced laser system generates high-quality laser beams for LCLS-II, contributing to the instrument's unprecedented brightness, precision, and flexibility. Our discussion extends to the various subsystems that comprise the photoinjector, including the photocathode laser, laser heater, and beam transport systems. Lastly, we draw attention to the ongoing research and development infrastructure underway to enhance the functionality and efficiency of the LCLS-II, and similar X-ray free-electron laser facilities around the world, thereby contributing to the future of laser technology and its applications.
The recent Segment Anything Model (SAM) 2 has demonstrated remarkable foundational competence in semantic segmentation, with its memory mechanism and mask decoder further addressing challenges in video tracking and object occlusion, thereby achieving superior results in interactive segmentation for both images and videos. Building upon our previous empirical studies, we further explore the zero-shot segmentation performance of SAM 2 in robot-assisted surgery based on prompts, alongside its robustness against real-world corruption. For static images, we employ two forms of prompts: 1-point and bounding box, while for video sequences, the 1-point prompt is applied to the initial frame. Through extensive experimentation on the MICCAI EndoVis 2017 and EndoVis 2018 benchmarks, SAM 2, when utilizing bounding box prompts, outperforms state-of-the-art (SOTA) methods in comparative evaluations. The results with point prompts also exhibit a substantial enhancement over SAM's capabilities, nearing or even surpassing existing unprompted SOTA methodologies. Besides, SAM 2 demonstrates improved inference speed and less performance degradation against various image corruption. Although slightly u
This paper deals with the control of laser spot in the context of minimally invasive surgery of the middle ear, e.g., cholesteatoma removal. More precisely, our work is concerned with the exhaustive burring of residual infected cells after primary mechanical resection of the pathological tissues since the latter cannot guarantee the treatment of all the infected tissues, the remaining infected cells cause regeneration of the diseases in 20%-25\-% of cases, which require a second surgery 12-18 months later. To tackle such a complex surgery, we have developed a robotic platform that consists of the combination of a macro-scale system (7 degrees of freedom (DoFs) robotic arm) and a micro-scale flexible system (2 DoFs) which operates inside the middle ear cavity. To be able to treat the residual cholesteatoma regions, we proposed a method to automatically generate optimal laser scanning trajectories inside the regions and between them. The trajectories are tacked using an image-based control scheme. The proposed method and materials were validated experimentally using the lab-made robotic platform. The obtained results in terms of accuracy and behaviour meet perfectly the laser surgery
The first time simultaneous measurements of sodium column density and the absolute flux from a sodium laser guide star, created by a monochromatic 3 W cw laser, tuned to the peak of the sodium D2 hyperfine structure, were conducted at the MMT and CFA 60 inch telescope in 1997. The results show that linearly and circularly polarized laser returns are proportional to the simultaneous sodium column density. Moreover, circularly polarized laser provides about 30% increase in fluorescent return over linearly polarized laser. A laser guide star with R = 10.3 mag. or absolute flux of 8.4x10^5 photons/s/m^2, could be formed from a 1 watt projected circularly polarized sodium laser beam when sodium layer abundance N(Na) = 3.7x10^9 /cm^2. Together with the distributed column density measurements (e.g. seasonal and diurnal variations), we can project laser power requirements for any specified guide star brightness. The mesosphere sodium column density variation was measured above Tucson sky throughout the year, through sodium absorption line measurements in stellar and solar spectra. Previous measurements, e.g. Papen et al, 1996, have not been made at this latitude (32 degrees). Further, our
This letter reports the design, construction, and experimental validation of a novel hand-held robot for in-office laser surgery of the vocal folds. In-office endoscopic laser surgery is an emerging trend in Laryngology: It promises to deliver the same patient outcomes of traditional surgical treatment (i.e., in the operating room), at a fraction of the cost. Unfortunately, office procedures can be challenging to perform; the optical fibers used for laser delivery can only emit light forward in a line-of-sight fashion, which severely limits anatomical access. The robot we present in this letter aims to overcome these challenges. The end effector of the robot is a steerable laser fiber, created through the combination of a thin optical fiber (0.225 mm) with a tendon-actuated Nickel-Titanium notched sheath that provides bending. This device can be seamlessly used with most commercially available endoscopes, as it is sufficiently small (1.1 mm) to pass through a working channel. To control the fiber, we propose a compact actuation unit that can be mounted on top of the endoscope handle, so that, during a procedure, the operating physician can operate both the endoscope and the steerab
The accumulation of atoms in the lowest energy level of a trap and the subsequent out-coupling of these atoms is a realization of a matter-wave analog of a conventional optical laser. Optical random lasers require materials that provide optical gain but, contrary to conventional lasers, the modes are determined by multiple scattering and not a cavity. We show that a Bose-Einstein condensate can be loaded in a spatially correlated disorder potential prepared in such a way that the Anderson localization phenomenon operates as a band-pass filter. A multiple scattering process selects atoms with certain momenta and determines laser modes which represents a matter-wave analog of an optical random laser.
Broadband laser ultrasonics and two dimensional Fourier transformation are used to characterize the properties of varieties of foils and plates. Laser ultrasonics generation is achieved by use of a pulsed laser which deposits pulsed laser energy on the surface of the specimen. The displacement amplitude of the resulting broadband ultrasonic modes are monitored using a two wave mixing photo-refractive interferometer. By applying a two dimensional Fourier transformation to the detected spatial and temporal displacement waveforms, the images of density of state (DOS) for the excited ultrasounds are obtained. Results are presented for a 150 um thick paper sample, a 52.8 um stainless steel foil and a 1.27 mm thick aluminum plate. The DOS image demonstrates the ability to measure the properties of each generated ultrasonic modes and provides a direct, non destructive, measure of elastic moduli of the tested specimens
Concept erasure in text-to-image diffusion models is crucial for mitigating harmful content, yet existing methods often compromise generative quality. We introduce Semantic Surgery, a novel training-free, zero-shot framework for concept erasure that operates directly on text embeddings before the diffusion process. It dynamically estimates the presence of target concepts in a prompt and performs a calibrated vector subtraction to neutralize their influence at the source, enhancing both erasure completeness and locality. The framework includes a Co-Occurrence Encoding module for robust multi-concept erasure and a visual feedback loop to address latent concept persistence. As a training-free method, Semantic Surgery adapts dynamically to each prompt, ensuring precise interventions. Extensive experiments on object, explicit content, artistic style, and multi-celebrity erasure tasks show our method significantly outperforms state-of-the-art approaches. We achieve superior completeness and robustness while preserving locality and image quality (e.g., 93.58 H-score in object erasure, reducing explicit content to just 1 instance, and 8.09 H_a in style erasure with no quality degradation).
Traditional wavefront control in high-energy, high-intensity laser systems usually lacks real-time capability, failing to address dynamic aberrations. This limits experimental accuracy due to shot-to-shot fluctuations and necessitates long cool-down phases to mitigate thermal effects, particularly as higher repetition rates become essential, e.g. in Inertial Fusion research. This paper details the development and implementation of a real-time capable adaptive optics system at the Apollon laser facility. Inspired by astronomical adaptive optics, the system uses a fiber-coupled 905 nm laser diode as a pilot beam that allows for spectral separation, bypassing the constraints of pulsed lasers. A GPU-based controller, built on the open-source CACAO framework, manages a loop comprising a bimorph deformable mirror and high-speed Shack-Hartmann sensor. Initial tests showed excellent stability and effective aberration correction. However, integration into the Apollon laser revealed critical challenges unique to the laser environment that must be resolved to ensure safe operation with amplified shots.
In this work, we focus on the fabrication of highly uniform laser-induced periodic surface structures (LIPSS) on bulk polycarbonate (PC) using 258 nm femtosecond laser pulses. A systematic approach was pursued to investigate the influence of various laser parameters such as fluence, effective number of pulses, energy dose and polarisation on the features of the generated LIPSS. Experimental results showed that linearly polarized beams produce LIPSS with period comparable to the laser wavelength. Moreover, it was observed that the orientation of LIPSS is either parallel or perpendicular to the laser polarization, depending on the excitation level. These features are similar to the LIPSS formed on dielectrics, despite the considerably higher absorption and larger extinction coefficient (~10-2) of polycarbonate at 258 nm. The orientation and features of the patterns at different excitation levels are explained using Sipe's theory, while the excitation and induced carrier densities were quantified through the application of a theoretical physical model that describes ultrafast dynamics in polymers. Furthermore, observations revealed that low excitation levels with linearly polarized en
This paper proposes a method to regulate the tissue temperature during laser surgery by robotically controlling the laser focus. Laser-tissue interactions are generally considered hard to control due to the inherent inhomogeneity of biological tissue, which can create significant variability in its thermal response to laser irradiation. In this study, we use methods from nonlinear control theory to synthesize a temperature controller capable of working on virtually any tissue type without any prior knowledge of its physical properties. The performance of the controller is evaluated in ex-vivo experiments.
Laser cooling by collisional redistribution of radiation has been successfully applied in the past for cooling dense atomic gases. Here we report on progress of work aiming at the demonstration of redistribution laser cooling in a molecular gas. The candidate molecule strontium monohydride is produced by laser ablation of strontium dihydride in a pressurized noble gas atmosphere. The composition of the ablation plasma plume is analyzed by measuring its emission spectrum. The dynamics of SrH molecular density following the ablation laser pulse is studied as a function of the buffer gas pressure and the laser intensity.
We scrutinize the behavior of eigenvalues of an electron of Helium atom as it interacts with electric field directed along $z$-axis and exposed to linearly polarized intense laser field radiation. In order to achieve this, we freeze one electron of the helium atom at its ionic ground state and the motion of the second electron in the ion core is treated via a more general case of screened Coulomb potential model. Using the Kramers-Henneberger (KH) unitary transformation, which is semiclassical counterpart of the Block-Nordsieck transformation in the quantized field formalism, the squared vector potential that appears in the equation of motion is eliminated and the resultant equation is expressed in KH frame. Within this frame, the resulting potential and the corresponding wave function have been expanded in Fourier series and using Ehlotzkys approximation, we obtain a laser-dressed potential to simulate intense laser field. By fitting the more general case of screened Coulomb potential model into the laser-dressed potential, and then expanding it in Taylor series up to $\mathcal{O}(r^4,α_0^9)$, we obtain the solution (eigenvalues and wave function) of an electron of Helium atom und
One of the most important issue in soft tissue modeling is to assess the quality of the simulations. A validation protocol is presented based on two CT scans of the patient acquired before and after cranio-maxillofacial surgery. The actual bones repositioning realized during the intervention are accurately measured and reproduced. A evaluation of the soft tissue deformation is then computed using a finite element model of the face. The simulations are therefore compared, qualitatively and quantitatively, with the actual outcome of the surgery. This protocol enable to rigorously evaluate different modeling methods, and to assess the clinical relevance of soft tissue simulation in maxillofacial surgery.
Objectives : This paper presents a new simulator for maxillo-facial surgery, that gathers the dental and the maxillo-facial analyses together into a single computer-assisted procedure. The idea is first to propose a repositioning of the maxilla, via the introduction of a 3D cephalometry, applied to a 3D virtual model of the patient's skull. Then, orthodontic data are integrated into this model, thanks to optical measurements of teeth plaster casts. Materials and Methods : The feasibility of the maxillo-facial demonstrator was first evaluated on a dry skull. To simulate malformations (and thus to simulate a "real" patient), the skull was modified and manually cut by the surgeon, in order to generate a given maxillo-facial malformation (with asymmetries in the sagittal, frontal and axial planes). Results : The validation of our simulator consisted in evaluating its ability to propose a bone repositioning diagnosis that will put the skull as it was in its original configuration. A first qualitative validation is provided in this paper, with a 1.5-mm error in the repositioning diagnosis. Conclusions : These results mainly validate the concept of a maxillo-facial numerical simulator tha