Pin sites represent the interface where a metal pin or wire from the external environment passes through the skin into the internal environment of the limb. These pins or wires connect an external fixator to the bone to stabilize the bone segments in a patient with trauma or deformity. Because these pin sites represent an opportunity for external skin flora to enter the internal environment of the limb, infections of the pin site are common. These pin site infections are painful, annoying, and cause increased morbidity to the patients. Improving the identification and management of pin site infections would greatly enhance the patient experience when external fixators are used. For this, this paper collects and produces a dataset on pin sites wound infections and proposes a deep learning (DL) method to classify pin sites images based on their appearance: Group A displayed signs of inflammation or infection, while Group B showed no evident complications. Unlike studies that primarily focus on open wounds, our research includes potential interventions at the metal pin/skin interface. Our attention-based deep learning model addresses this complexity by emphasizing relevant regions and
Sample size calculations play a central role in study design because sample size affects study interpretability, costs, hospital resources, and staff time. For most veterinary orthopaedic risk-factor studies, either the sample size calculation or the post-hoc power calculation assumes the disease status of control subjects is perfectly ascertained, when it may not be. That means control groups may be mixtures of both unaffected cases and some unidentified affected cases. In this study, we demonstrate the consequences of using misclassified groups as control groups on the power of risk association tests, with the intent of showing that control groups with even small misclassification rates can reduce the power of association tests. In addition, we offer a range of correction factors to adjust sample size calculations back to 80% power. This was a simulation study using study designs from published orthopaedic risk-factor studies. The approach was to use their designs but simulate the data to include known proportions of misclassified affected subjects in the control group. The simulated data was used to calculate the power of a risk-association test. We calculated powers for several
Background. Osteoarthritis affects about 528 million people worldwide, causing pain and stiffness in the joints. Arthroplasty is commonly performed to treat joint osteoarthritis, reducing pain and improving mobility. Nevertheless, a significant share of patients remain unsatisfied with their surgery. Personalised arthroplasty was introduced to improve surgical outcomes however current solutions require delays, making it difficult to integrate in clinical routine. We propose a fully automated workflow to design patient-specific implants for total knee arthroplasty. Methods. The proposed pipeline first uses artificial neural networks to segment the femur and tibia proximal and distal extremities. Then the full bones are reconstructed using augmented statistical shape models, combining shape and landmarks information. Finally, 77 morphological parameters are computed to design patient-specific implants. The developed workflow has been trained on 91 CT scans and evaluated on 41 CT scans, in terms of accuracy and execution time. Results. The workflow accuracy was $0.4\pm0.2mm$ for segmentation, $1.0\pm0.3mm$ for full bone reconstruction, and $2.2\pm1.5mm$ for anatomical landmarks determ
The most recent advances in medical imaging that have transformed diagnosis, especially in the case of interpreting X-ray images, are actively involved in the healthcare sector. The advent of digital image processing technology and the implementation of deep learning models such as Convolutional Neural Networks (CNNs) have made the analysis of X-rays much more accurate and efficient. In this article, some essential techniques such as edge detection, region-growing technique, and thresholding approach, and the deep learning models such as variants of YOLOv8-which is the best object detection and segmentation framework-are reviewed. We further investigate that the traditional image processing techniques like segmentation are very much simple and provides the alternative to the advanced methods as well. Our review gives useful knowledge on the practical usage of the innovative and traditional approaches of manual X-ray interpretation. The discovered information will help professionals and researchers to gain more profound knowledge in digital interpretation techniques in medical imaging.
Robotic-assisted orthopaedic surgeries demand accurate, automated leg manipulation for improved spatial accuracy to reduce iatrogenic damage. In this study, we propose novel rigid body designs and an optical tracking volume setup for tracking of the femur, tibia and surgical instruments. Anatomical points inside the leg are measured using Computed Tomography with an accuracy of 0.3mm. Combined with kinematic modelling, we can express these points relative to any frame and across joints to sub-millimetre accuracy. It enables the setup of vectors on the mechanical axes of the femur and tibia for kinematic analysis. Cadaveric experiments are used to verify the tracking of internal anatomies and joint motion analysis. The proposed integrated solution is a first step in the automation of leg manipulation and can be used as a ground-truth for future robot-assisted orthopaedic research.
Fluoroscopic X-ray guidance is a cornerstone for percutaneous orthopaedic surgical procedures. However, two-dimensional observations of the three-dimensional anatomy suffer from the effects of projective simplification. Consequently, many X-ray images from various orientations need to be acquired for the surgeon to accurately assess the spatial relations between the patient's anatomy and the surgical tools. In this paper, we present an on-the-fly surgical support system that provides guidance using augmented reality and can be used in quasi-unprepared operating rooms. The proposed system builds upon a multi-modality marker and simultaneous localization and mapping technique to co-calibrate an optical see-through head mounted display to a C-arm fluoroscopy system. Then, annotations on the 2D X-ray images can be rendered as virtual objects in 3D providing surgical guidance. We quantitatively evaluate the components of the proposed system, and finally, design a feasibility study on a semi-anthropomorphic phantom. The accuracy of our system was comparable to the traditional image-guided technique while substantially reducing the number of acquired X-ray images as well as procedure time
Conventional computer-assisted orthopaedic navigation systems rely on the tracking of dedicated optical markers for patient poses, which makes the surgical workflow more invasive, tedious, and expensive. Visual tracking has recently been proposed to measure the target anatomy in a markerless and effortless way, but the existing methods fail under real-world occlusion caused by intraoperative interventions. Furthermore, such methods are hardware-specific and not accurate enough for surgical applications. In this paper, we propose a RGB-D sensing-based markerless tracking method that is robust against occlusion. We design a new segmentation network that features dynamic region-of-interest prediction and robust 3D point cloud segmentation. As it is expensive to collect large-scale training data with occlusion instances, we also propose a new method to create synthetic RGB-D images for network training. Experimental results show that our proposed markerless tracking method outperforms recent state-of-the-art approaches by a large margin, especially when an occlusion exists. Furthermore, our method generalises well to new cameras and new target models, including a cadaver, without the n
Alumina-zirconia nano-composites were recently developed as alternative bearing materials for orthopedics. Previous, preliminary reports show that such alumina-zirconia nanocomposites exhibit high crack resistance and low wear rate. In this paper, additional information is given in terms of wear, crack resistance and ageing behaviour: femoral heads are inspected after 7 million cycles of wear testing on a hip simulator, crack resistance is measured and compared to other ceramics used today in orthopedics, slow crack growth is reported under static and cyclic fatigue, and aging resistance is assessed. We also report on the load to failure of femoral heads prototypes during compression tests. This overall reliability assessment ensures a potential future development for these kinds of new nanocomposites in the orthopedic field.
Antimicrobial photodynamic therapy (aPDT) is a promising modality for inactivation of antibiotic resistant bacteria, relying on the activation of a photosensitizer (PS) by light of a specific wavelength. This process results in the formation of reactive oxygen species, which ultimately induce cell death. However, aPDT in its conventional form, is limited by the shallow penetration of visible light, restricting its effectiveness for treatment of soft tissue and orthopaedic tissues. To overcome this limitation, near-infrared (NIR) absorbing PS can be used. However, poor stability in vivo after injection, ineffective microbial targeting due to hydrophilic nature and off-site tissue damage are the issues with use of NIR absorbing bare PSs. This issue can be mitigated by combining NIR light with a upconverting nanoparticles (UCNPs), which mediate in conversion of NIR into visible light for effective PS activation. In this study, LaF$_3$:Er$^{3+}$,Yb$^{3+}$ nanoparticles were synthesized using a hydrothermal method and coated with Rose Bengal (RB), a promising hydrophilic PS for aPDT, to evaluate the potential for NIR-triggered aPDT. Characterization of the synthesized UCNPs confirmed th
Musculoskeletal diseases are among the leading causes of disability and drive the greatest global need for rehabilitation. Because recovery, remodelling and degeneration of bones, joints and related tissues unfold over months to years, care requires longitudinal management rather than isolated decisions. Clinicians must repeatedly integrate evolving patient evidence, medical knowledge and stage-specific functional goals, yet evidence is often fragmented across visits, departments and hospital systems, disrupting continuous, individualised management. Here we report OrthoPilot, a clinical artificial intelligence (AI) system powered by a large language model (LLM) that integrates hospital data streams with authoritative external knowledge for continuous musculoskeletal care. It autonomously retrieves real-time imaging, laboratory, pathology and order data and translates evolving patient states into evidence-based decisions from admission diagnosis through rehabilitation planning. We established a specialist-validated benchmark from real-world electronic health records (EHRs) spanning 1,000 disease codes. In a full-pathway reader study against 81 orthopaedic physicians, OrthoPilot out
Radiographic images are a cornerstone of medical diagnostics in orthopaedics, with anatomical landmark detection serving as a crucial intermediate step for information extraction. General-purpose foundational segmentation models, such as SAM (Segment Anything Model), do not support landmark segmentation out of the box and require prompts to function. However, in medical imaging, the prompts for landmarks are highly specific. Since SAM has not been trained to recognize such landmarks, it cannot generate accurate landmark segmentations for diagnostic purposes. Even MedSAM, a medically adapted variant of SAM, has been trained to identify larger anatomical structures, such as organs and their parts, and lacks the fine-grained precision required for orthopaedic pelvic landmarks. To address this limitation, we propose leveraging another general-purpose, non-foundational model: YOLO. YOLO excels in object detection and can provide bounding boxes that serve as input prompts for SAM. While YOLO is efficient at detection, it is significantly outperformed by SAM in segmenting complex structures. In combination, these two models form a reliable pipeline capable of segmenting not only a small p
Automating data extraction from full-text randomised controlled trials (RCTs) for meta-analysis remains a significant challenge. This study evaluates the practical performance of three LLMs (Gemini-2.0-flash, Grok-3, GPT-4o-mini) across tasks involving statistical results, risk-of-bias assessments, and study-level characteristics in three medical domains: hypertension, diabetes, and orthopaedics. We tested four distinct prompting strategies (basic prompting, self-reflective prompting, model ensemble, and customised prompts) to determine how to improve extraction quality. All models demonstrate high precision but consistently suffer from poor recall by omitting key information. We found that customised prompts were the most effective, boosting recall by up to 15\%. Based on this analysis, we propose a three-tiered set of guidelines for using LLMs in data extraction, matching data types to appropriate levels of automation based on task complexity and risk. Our study offers practical advice for automating data extraction in real-world meta-analyses, balancing LLM efficiency with expert oversight through targeted, task-specific automation.
By 2050, a quarter of the US population will be over the age of 65 with greater than a 40% risk of developing life-altering neuromusculoskeletal pathologies. The potential of wearables, such as Apple AirPods and hearing aids, to provide personalized preventative and predictive health monitoring outside of the clinic is nascent, but large quantities of open-ended data that capture movement in the physical world now exist. Algorithms that leverage existing wearable technology to detect subtle changes to walking mechanics, an early indicator of neuromusculoskeletal pathology, have successfully been developed to determine population-level statistics, but individual-level variability is more difficult to parse from population-level data. Like genetic sequencing, the individual's gait pattern can be discerned by decomposing the movement signal into its fundamental features from which we can detect "mutations" or changes to the pattern that are early indicators of pathology - movement-based biomarkers. We have developed a novel approach to quantify "normal baseline movement" at an individual level, combining methods from gait laboratories with methods used to characterize stellar oscillat
Compliant mechanisms have significant potential in precision applications due to their ability to guide motion without contact. However, an inherent vulnerability to fatigue and mechanical failure has hindered the translation of compliant mechanisms to real-world applications. This is particularly challenging in service environments where loading is complex and uncertain, and the cost of failure is high. In such cases, mechanical hard stops are critical to prevent yielding and buckling. Conventional hard-stop designs, which rely on stacking single-DOF limits, must be overly restrictive in multi-DOF space to guarantee safety in the presence of unknown loads. In this study, we present a systematic design synthesis method to guarantee overload protection in compliant mechanisms by integrating coupled multi-DOF motion limits within a single pair of compact hard-stop surfaces. Specifically, we introduce a theoretical and practical framework for optimizing the contact surface geometry to maximize the mechanisms multi-DOF working space while still ensuring that the mechanism remains within its elastic regime. We apply this synthesis method to a case study of a caged-hinge mechanism for or
The individual contributions of pH and chloride concentration to the corrosion kinetics of bioabsorbable magnesium (Mg) alloys remain unresolved despite their significant roles as driving factors in Mg corrosion. This study demonstrates and quantifies hitherto unknown separate effects of pH and chloride content on the corrosion of Mg alloys pertinent to biomedical implant applications. The experimental setup designed for this purpose enables the quantification of the dependence of corrosion on pH and chloride concentration. The in vitro tests conclusively demonstrate that variations in chloride concentration, relevant to biomedical applications, have a negligible effect on corrosion kinetics. The findings identify pH as a critical factor in the corrosion of bioabsorbable Mg alloys. A variationally consistent phase-field model is developed for assessing the degradation of Mg alloys in biological fluids. The model accurately predicts the corrosion performance of Mg alloys observed during the experiments, including their dependence on pH and chloride concentration. The capability of the framework to account for mechano-chemical effects during corrosion is demonstrated in practical ort
Pelvic bone tumor resections remain significantly challenging due to complex three-dimensional anatomy and limited surgical visualization. Current navigation systems and patient-specific instruments, while accurate, present limitations including high costs, radiation exposure, workflow disruption, long production time, and lack of reusability. This study evaluates a real-time vision-guided surgical system combined with modular jigs to improve accuracy in pelvic bone tumor resections. A vision-guided surgical system combined with modular cutting jigs and real-time optical tracking was developed and validated. Five female pelvis sawbones were used, with each hemipelvis randomly assigned to either the vision-guided and modular jig system or traditional freehand method. A total of twenty resection planes were analyzed for each method. Accuracy was assessed by measuring distance and angular deviations from the planned resection planes. The vision-guided and modular jig system significantly improved resection accuracy compared to the freehand method, reducing the mean distance deviation from 2.07 $\pm$ 1.71 mm to 1.01 $\pm$ 0.78 mm (p=0.0193). In particular, all specimens resected using
Deep learning based approaches have been used to improve image quality in cone-beam computed tomography (CBCT), a medical imaging technique often used in applications such as image-guided radiation therapy, implant dentistry or orthopaedics. In particular, while deep learning methods have been applied to reduce various types of CBCT image artifacts arising from motion, metal objects, or low-dose acquisition, a comprehensive review summarizing the successes and shortcomings of these approaches, with a primary focus on the type of artifacts rather than the architecture of neural networks, is lacking in the literature. In this review, the data generation and simulation pipelines, and artifact reduction techniques are specifically investigated for each type of artifact. We provide an overview of deep learning techniques that have successfully been shown to reduce artifacts in 3D, as well as in time-resolved (4D) CBCT through the use of projection- and/or volume-domain optimizations, or by introducing neural networks directly within the CBCT reconstruction algorithms. Research gaps are identified to suggest avenues for future exploration. One of the key findings of this work is an obser
Plantar pressure measurements can provide valuable insight into various health characteristics in patients. In this study, we describe different plantar pressure devices available on the market and their clinical relevance. Current devices are either platform-based or wearable and consist of a variety of sensor technologies: resistive, capacitive, piezoelectric, and optical. The measurements collected from any of these sensors can be utilized for a range of clinical applications including patients with diabetes, trauma, deformity and cerebral palsy, stroke, cervical myelopathy, ankle instability, sports injuries, and Parkinsons disease. However, the proper technology should be selected based on the clinical need and the type of tests being performed on the device. In this review we provide the reader with a simple overview of the existing technologies their advantages and disadvantages and provide application examples for each. Moreover, we suggest new areas in orthopaedic that plantar pressure mapping technology can be utilized for increased quality of care.
This research proposal discusses two challenges in the field of medical image analysis: the multi-parametric investigation on microstructural and macrostructural characteristics of the cervical spinal cord and deep learning-based medical image segmentation. First, we conduct a thorough analysis of the cervical spinal cord within a healthy population. Unlike most previous studies, which required medical professionals to perform functional examinations using metrics like the modified Japanese Orthopaedic Association (mJOA) score or the American Spinal Injury Association (ASIA) impairment scale, this research focuses solely on Magnetic Resonance (MR) images of the cervical spinal cord. Second, we employ cutting-edge deep learning-based segmentation methods to achieve highly accurate macrostructural measurements from MR images. To this end, we propose an enhanced UNet-like Transformer-based framework with attentive skip connections. This paper reports on the problem domain, proposed solutions, current status of research, and expected contributions.
Augmented reality (AR) has the potential to improve the immersion and efficiency of computer-assisted orthopaedic surgery (CAOS) by allowing surgeons to maintain focus on the operating site rather than external displays in the operating theatre. Successful deployment of AR to CAOS requires a calibration that can accurately calculate the spatial relationship between real and holographic objects. Several studies attempt this calibration through manual alignment or with additional fiducial markers in the surgical scene. We propose a calibration system that offers a direct method for the calibration of AR head-mounted displays (HMDs) with CAOS systems, by using infrared-reflective marker-arrays widely used in CAOS. In our fast, user-agnostic setup, a HoloLens 2 detected the pose of marker arrays using infrared response and time-of-flight depth obtained through sensors onboard the HMD. Registration with a commercially available CAOS system was achieved when an IR marker-array was visible to both devices. Study tests found relative-tracking mean errors of 2.03 mm and 1.12° when calculating the relative pose between two static marker-arrays at short ranges. When using the calibration resu