In ophthalmic surgery, developing an AI system capable of interpreting surgical videos and predicting subsequent operations requires numerous ophthalmic surgical videos with high-quality annotations, which are difficult to collect due to privacy concerns and labor consumption. Text-guided video generation (T2V) emerges as a promising solution to overcome this issue by generating ophthalmic surgical videos based on surgeon instructions. In this paper, we present Ophora, a pioneering model that can generate ophthalmic surgical videos following natural language instructions. To construct Ophora, we first propose a Comprehensive Data Curation pipeline to convert narrative ophthalmic surgical videos into a large-scale, high-quality dataset comprising over 160K video-instruction pairs, Ophora-160K. Then, we propose a Progressive Video-Instruction Tuning scheme to transfer rich spatial-temporal knowledge from a T2V model pre-trained on natural video-text datasets for privacy-preserved ophthalmic surgical video generation based on Ophora-160K. Experiments on video quality evaluation via quantitative analysis and ophthalmologist feedback demonstrate that Ophora can generate realistic and re
Visual Question Answering (VQA) holds great promise for clinical support, particularly in ophthalmology, where retinal fundus photography is essential for diagnosis. However, ophthalmic VQA benchmarks primarily emphasize answer accuracy, neglecting the explicit visual evidence necessary for clinical interpretability. In this work, we introduce FundusGround, a new benchmark for clinically interpretable ophthalmic VQA with spatially-grounded lesion evidence. Specifically, we propose a three-stage pipeline that collects 10,719 fundus images with 15,595 image-level meticulously annotated lesions. To ensure anatomical consistency and clinical validity, all lesions are spatially localized using the Early Treatment Diabetic Retinopathy Study (ETDRS) grid, enabling standardized mapping to nine clinically meaningful retinal regions. Built upon this structured lesion evidence, 72,706 questions are then generated spanning four formats: open-ended, closed-ended, single-choice, and multiple-choice. We further benchmark multiple general- and medical- large vision-language models using dual metrics for answer accuracy and lesion-level reasoning. The experiments demonstrate that incorporating lesi
The conventional manufacturing of ophthalmic lenses is an inefficient subtractive process where up to 97% of the material is discarded through grinding, polishing, and edging. Fluidic Shaping has emerged as a powerful alternative, utilizing surface tension to form optical-quality surfaces. While the approach enabled the creation of ophthalmic lenses without grinding or polishing, it was limited to lenses with a circular or elliptical footprint and still required the wasteful edging process to fit the lenses into the eyewear rims. Here, the Cookie Cutter algorithm is introduced, generalizing the Fluidic Shaping approach to be applicable to arbitrary domains, thus eliminating all subtractive processes. This mathematical framework calculates the unique varying edge-height required for a boundary frame, allowing a liquid polymer to naturally settle into a target spherocylindrical prescription within an arbitrary rim footprint. By utilizing neutral buoyancy to negate gravity, the liquid polymer is shaped solely by surface tension and subsequently cured, resulting in a lens that fits directly into commercial eyewear rims without any mechanical post-processing. The method is validated exp
Foundation models (FMs) have shown great promise in medical image analysis by improving generalization across diverse downstream tasks. In ophthalmology, several FMs have recently emerged, but there is still no clear answer to fundamental questions: Which FM performs the best? Are they equally good across different tasks? What if we combine all FMs together? To our knowledge, this is the first study to systematically evaluate both single and fused ophthalmic FMs. To address these questions, we propose FusionFM, a comprehensive evaluation suite, along with two fusion approaches to integrate different ophthalmic FMs. Our framework covers both ophthalmic disease detection (glaucoma, diabetic retinopathy, and age-related macular degeneration) and systemic disease prediction (diabetes and hypertension) based on retinal imaging. We benchmarked four state-of-the-art FMs (RETFound, VisionFM, RetiZero, and DINORET) using standardized datasets from multiple countries and evaluated their performance using AUC and F1 metrics. Our results show that DINORET and RetiZero achieve superior performance in both ophthalmic and systemic disease tasks, with RetiZero exhibiting stronger generalization on
Medical Large Language Models (MLLMs) play a crucial role in ophthalmic diagnosis, holding significant potential to address vision-threatening diseases. However, their accuracy is constrained by hallucinations stemming from limited ophthalmic knowledge, insufficient visual localization and reasoning capabilities, and a scarcity of multimodal ophthalmic data, which collectively impede precise lesion detection and disease diagnosis. Furthermore, existing medical benchmarks fail to effectively evaluate various types of hallucinations or provide actionable solutions to mitigate them. To address the above challenges, we introduce EH-Benchmark, a novel ophthalmology benchmark designed to evaluate hallucinations in MLLMs. We categorize MLLMs' hallucinations based on specific tasks and error types into two primary classes: Visual Understanding and Logical Composition, each comprising multiple subclasses. Given that MLLMs predominantly rely on language-based reasoning rather than visual processing, we propose an agent-centric, three-phase framework, including the Knowledge-Level Retrieval stage, the Task-Level Case Studies stage, and the Result-Level Validation stage. Experimental results s
High-fidelity surgical video generation can greatly improve medical training and the development of AI, adapting these generative models for precise video editing remains a formidable challenge. Modifying surgical attributes, such as instrument tissue interactions or procedural phases is challenging due to the strict anatomical and temporal constraints. In this paper, we propose OphEdit, a novel training-free framework for the text-guided editing of ophthalmic surgical videos. Our approach leverages a deterministic second-order ODE inversion pipeline to capture Attention Value (V) tensors from the original video. By selectively injecting these stored tensors into the conditional Classifier-Free Guidance (CFG) branch during the denoising phase, OphEdit rigorously preserves the intricate anatomical geometry of the eye while seamlessly mapping text-driven semantic modifications onto the video stream. Clinical evaluations demonstrates that OphEdit effectively handles complex surgical transformations, such as instrument swaps and procedural variations, with superior structural fidelity and temporal consistency compared to natural-domain video editors. Our work represents the first appli
Purpose: To develop a bilingual multimodal visual question answering (VQA) benchmark for evaluating VLMs in ophthalmology. Methods: Ophthalmic image posts and associated captions published between January 1, 2016, and December 31, 2024, were collected from WeChat Official Accounts. Based on these captions, bilingual question-answer (QA) pairs in Chinese and English were generated using GPT-4o-mini. QA pairs were categorized into six subsets by question type and language: binary (Binary_CN, Binary_EN), single-choice (Single-choice_CN, Single-choice_EN), and open-ended (Open-ended_CN, Open-ended_EN). The benchmark was used to evaluate the performance of three VLMs: GPT-4o, Gemini 2.0 Flash, and Qwen2.5-VL-72B-Instruct. Results: The final OphthalWeChat dataset included 3,469 images and 30,120 QA pairs across 9 ophthalmic subspecialties, 548 conditions, 29 imaging modalities, and 68 modality combinations. Gemini 2.0 Flash achieved the highest overall accuracy (0.548), outperforming GPT-4o (0.522, P < 0.001) and Qwen2.5-VL-72B-Instruct (0.514, P < 0.001). It also led in both Chinese (0.546) and English subsets (0.550). Subset-specific performance showed Gemini 2.0 Flash excelled i
Cataract surgery remains one of the most widely performed and effective procedures for vision restoration. Effective surgical planning requires integrating diverse clinical examinations for patient assessment, intraocular lens (IOL) selection, and risk evaluation. Large language models (LLMs) have shown promise in supporting clinical decision-making. However, existing LLMs often lack the domain-specific expertise to interpret heterogeneous ophthalmic data and provide actionable surgical plans. To enhance the model's ability to interpret heterogeneous ophthalmic reports, we propose a knowledge-driven Multi-Agent System (MAS), where each agent simulates the reasoning process of specialist ophthalmologists, converting raw clinical inputs into structured, actionable summaries in both training and deployment stages. Building on MAS, we introduce CataractSurg-80K, the first large-scale benchmark for cataract surgery planning that incorporates structured clinical reasoning. Each case is annotated with diagnostic questions, expert reasoning chains, and structured surgical recommendations. We further introduce Qwen-CSP, a domain-specialized model built on Qwen-4B, fine-tuned through a multi
Accurate 3D reconstruction of hands and instruments is critical for vision-based analysis of ophthalmic microsurgery, yet progress has been hampered by the lack of realistic, large-scale datasets and reliable annotation tools. In this work, we introduce OphNet-3D, the first extensive RGB-D dynamic 3D reconstruction dataset for ophthalmic surgery, comprising 41 sequences from 40 surgeons and totaling 7.1 million frames, with fine-grained annotations of 12 surgical phases, 10 instrument categories, dense MANO hand meshes, and full 6-DoF instrument poses. To scalably produce high-fidelity labels, we design a multi-stage automatic annotation pipeline that integrates multi-view data observation, data-driven motion prior with cross-view geometric consistency and biomechanical constraints, along with a combination of collision-aware interaction constraints for instrument interactions. Building upon OphNet-3D, we establish two challenging benchmarks-bimanual hand pose estimation and hand-instrument interaction reconstruction-and propose two dedicated architectures: H-Net for dual-hand mesh recovery and OH-Net for joint reconstruction of two-hand-two-instrument interactions. These models le
Visual impairment represents a major global health challenge, with multimodal imaging providing complementary information that is essential for accurate ophthalmic diagnosis. This comprehensive survey systematically reviews the latest advances in multimodal deep learning methods in ophthalmology up to the year 2025. The review focuses on two main categories: task-specific multimodal approaches and large-scale multimodal foundation models. Task-specific approaches are designed for particular clinical applications such as lesion detection, disease diagnosis, and image synthesis. These methods utilize a variety of imaging modalities including color fundus photography, optical coherence tomography, and angiography. On the other hand, foundation models combine sophisticated vision-language architectures and large language models pretrained on diverse ophthalmic datasets. These models enable robust cross-modal understanding, automated clinical report generation, and decision support. The survey critically examines important datasets, evaluation metrics, and methodological innovations including self-supervised learning, attention-based fusion, and contrastive alignment. It also discusses
Medical image classification is a core task in computer-aided diagnosis (CAD), playing a pivotal role in early disease detection, treatment planning, and patient prognosis assessment. In ophthalmic practice, fluorescein fundus angiography (FFA) and indocyanine green angiography (ICGA) provide hemodynamic and lesion-structural information that conventional fundus photography cannot capture. However, due to the single-modality nature, subtle lesion patterns, and significant inter-device variability, existing methods still face limitations in generalization and high-confidence prediction. To address these challenges, we propose CLEAR-Mamba, an enhanced framework built upon MedMamba with optimizations in both architecture and training strategy. Architecturally, we introduce HaC, a hypernetwork-based adaptive conditioning layer that dynamically generates parameters according to input feature distributions, thereby improving cross-domain adaptability. From a training perspective, we develop RaP, a reliability-aware prediction scheme built upon evidential uncertainty learning, which encourages the model to emphasize low-confidence samples and improves overall stability and reliability. We
Multimodal ophthalmic imaging-based diagnosis integrates color fundus image with optical coherence tomography (OCT) to provide a comprehensive view of ocular pathologies. However, the uneven global distribution of healthcare resources often results in real-world clinical scenarios encountering incomplete multimodal data, which significantly compromises diagnostic accuracy. Existing commonly used pipelines, such as modality imputation and distillation methods, face notable limitations: 1)Imputation methods struggle with accurately reconstructing key lesion features, since OCT lesions are localized, while fundus images vary in style. 2)distillation methods rely heavily on fully paired multimodal training data. To address these challenges, we propose a novel multimodal alignment and fusion framework capable of robustly handling missing modalities in the task of ophthalmic diagnostics. By considering the distinctive feature characteristics of OCT and fundus images, we emphasize the alignment of semantic features within the same category and explicitly learn soft matching between modalities, allowing the missing modality to utilize existing modality information, achieving robust cross-m
Early ophthalmic screening in low-resource and remote settings is constrained by access to specialized equipment and trained practitioners. We present SKINOPATHY AI, a smartphone-first web application that delivers five complementary, explainable screening modules entirely through commodity mobile hardware: (1) redness quantification via LAB a* color-space normalization; (2) blink-rate estimation using MediaPipe FaceMesh Eye Aspect Ratio (EAR) with adaptive thresholding; (3) pupil light reflex characterization through Pupil-to-Iris Ratio (PIR) time-series analysis; (4) scleral color indexing foricterus and anemia proxies via LAB/HSV statistics; and (5) iris-landmark-calibrated lesion encroachment measurement with millimeter-scale estimates and longitudinal trend tracking. The system is implemented as a React/FastAPI stack with OpenCV and MediaPipe, MongoDB-backed session persistence, and PDF report generation. All algorithms are fully deterministic, privacy-preserving, and designed for non-diagnostic consumer triage. We detail system architecture, algorithm design, evaluation methodology, clinical context, and ethical boundaries of the platform. SKINOPATHY AI demonstrates that mult
We present VisionFM, a foundation model pre-trained with 3.4 million ophthalmic images from 560,457 individuals, covering a broad range of ophthalmic diseases, modalities, imaging devices, and demography. After pre-training, VisionFM provides a foundation to foster multiple ophthalmic artificial intelligence (AI) applications, such as disease screening and diagnosis, disease prognosis, subclassification of disease phenotype, and systemic biomarker and disease prediction, with each application enhanced with expert-level intelligence and accuracy. The generalist intelligence of VisionFM outperformed ophthalmologists with basic and intermediate levels in jointly diagnosing 12 common ophthalmic diseases. Evaluated on a new large-scale ophthalmic disease diagnosis benchmark database, as well as a new large-scale segmentation and detection benchmark database, VisionFM outperformed strong baseline deep neural networks. The ophthalmic image representations learned by VisionFM exhibited noteworthy explainability, and demonstrated strong generalizability to new ophthalmic modalities, disease spectrum, and imaging devices. As a foundation model, VisionFM has a large capacity to learn from div
Ophthalmic image segmentation serves as a critical foundation for ocular disease diagnosis. Although fully convolutional neural networks (CNNs) are commonly employed for segmentation, they are constrained by inductive biases and face challenges in establishing long-range dependencies. Transformer-based models address these limitations but introduce substantial computational overhead. Recently, a simple yet efficient Multilayer Perceptron (MLP) architecture was proposed for image classification, achieving competitive performance relative to advanced transformers. However, its effectiveness for ophthalmic image segmentation remains unexplored. In this paper, we introduce MM-UNet, an efficient Mixed MLP model tailored for ophthalmic image segmentation. Within MM-UNet, we propose a multi-scale MLP (MMLP) module that facilitates the interaction of features at various depths through a grouping strategy, enabling simultaneous capture of global and local information. We conducted extensive experiments on both a private anterior segment optical coherence tomography (AS-OCT) image dataset and a public fundus image dataset. The results demonstrated the superiority of our MM-UNet model in comp
Automatic ophthalmic disease diagnosis on fundus images is important in clinical practice. However, due to complex fundus textures and limited annotated data, developing an effective automatic method for this problem is still challenging. In this paper, we present a self-supervised method via polar transformation based progressive contrastive learning, called PoCo, for ophthalmic disease diagnosis. Specifically, we novelly inject the polar transformation into contrastive learning to 1) promote contrastive learning pre-training to be faster and more stable and 2) naturally capture task-free and rotation-related textures, which provides insights into disease recognition on fundus images. Beneficially, simple normal translation-invariant convolution on transformed images can equivalently replace the complex rotation-invariant and sector convolution on raw images. After that, we develop a progressive contrastive learning method to efficiently utilize large unannotated images and a novel progressive hard negative sampling scheme to gradually reduce the negative sample number for efficient training and performance enhancement. Extensive experiments on three public ophthalmic disease data
Ophthalmic surgical robots offer superior stability and precision by reducing the natural hand tremors of human surgeons, enabling delicate operations in confined surgical spaces. Despite the advancements in developing vision- and force-based control methods for surgical robots, preoperative navigation remains heavily reliant on manual operation, limiting the consistency and increasing the uncertainty. Existing eye gaze estimation techniques in the surgery, whether traditional or deep learning-based, face challenges including dependence on additional sensors, occlusion issues in surgical environments, and the requirement for facial detection. To address these limitations, this study proposes an innovative eye localization and tracking method that combines machine learning with traditional algorithms, eliminating the requirements of landmarks and maintaining stable iris detection and gaze estimation under varying lighting and shadow conditions. Extensive real-world experiment results show that our proposed method has an average estimation error of 0.58 degrees for eye orientation estimation and 2.08-degree average control error for the robotic arm's movement based on the calculated
Ophthalmic images and derivatives such as the retinal nerve fiber layer (RNFL) thickness map are crucial for detecting and monitoring ophthalmic diseases (e.g., glaucoma). For computer-aided diagnosis of eye diseases, the key technique is to automatically extract meaningful features from ophthalmic images that can reveal the biomarkers (e.g., RNFL thinning patterns) linked to functional vision loss. However, representation learning from ophthalmic images that links structural retinal damage with human vision loss is non-trivial mostly due to large anatomical variations between patients. The task becomes even more challenging in the presence of image artifacts, which are common due to issues with image acquisition and automated segmentation. In this paper, we propose an artifact-tolerant unsupervised learning framework termed EyeLearn for learning representations of ophthalmic images. EyeLearn has an artifact correction module to learn representations that can best predict artifact-free ophthalmic images. In addition, EyeLearn adopts a clustering-guided contrastive learning strategy to explicitly capture the intra- and inter-image affinities. During training, images are dynamically
Ophthalmic diseases represent a significant global health issue, necessitating the use of advanced precise diagnostic tools. Optical Coherence Tomography (OCT) imagery which offers high-resolution cross-sectional images of the retina has become a pivotal imaging modality in ophthalmology. Traditionally physicians have manually detected various diseases and biomarkers from such diagnostic imagery. In recent times, deep learning techniques have been extensively used for medical diagnostic tasks enabling fast and precise diagnosis. This paper presents a novel approach for ophthalmic biomarker detection using an ensemble of Convolutional Neural Network (CNN) and Vision Transformer. While CNNs are good for feature extraction within the local context of the image, transformers are known for their ability to extract features from the global context of the image. Using an ensemble of both techniques allows us to harness the best of both worlds. Our method has been implemented on the OLIVES dataset to detect 6 major biomarkers from the OCT images and shows significant improvement of the macro averaged F1 score on the dataset.
Ultrasound imaging reveals eye morphology and aids in diagnosing and treating eye diseases. However, interpreting diagnostic reports requires specialized physicians. We present a labeled ophthalmic dataset for the precise analysis and the automated exploration of medical images along with their associated reports. It collects three modal data, including the ultrasound images, blood flow information and examination reports from 2,417 patients at an ophthalmology hospital in Shenyang, China, during the year 2018, in which the patient information is de-identified for privacy protection. To the best of our knowledge, it is the only ophthalmic dataset that contains the three modal information simultaneously. It incrementally consists of 4,858 images with the corresponding free-text reports, which describe 15 typical imaging findings of intraocular diseases and the corresponding anatomical locations. Each image shows three kinds of blood flow indices at three specific arteries, i.e., nine parameter values to describe the spectral characteristics of blood flow distribution. The reports were written by ophthalmologists during the clinical care. The proposed dataset is applied to generate m