共找到 20 条结果
Clinical framing -- the linguistic manner in which clinical information is presented -- can influence patient understanding and decision-making, with important implications for healthcare outcomes. Obstetrics is a high-stakes domain in which physicians counsel patients on delivery mode choices such as vaginal birth after cesarean (VBAC) and repeat cesarean section (RCS), yet counseling language remains underexplored in large-scale clinical text analysis. In this work, we analyze physician counseling language in 2,024 obstetric history and physical narratives for a rigorously defined cohort of patients for whom both VBAC and RCS were clinically viable options. To control for confounding due to medical contraindications, we first construct a VBAC-eligible cohort using structured clinical data supplemented by a large language model (LLM)-based extraction pipeline constrained to grounded, verbatim evidence from free-text narratives. We then apply a zero-shot LLM framework to categorize counseling segments into predefined framing categories capturing how physicians linguistically present delivery options. Our analysis reveals a significant difference in counseling framing distributions
Clinician skepticism toward opaque AI hinders adoption in high-stakes healthcare. We present AICare, an interactive and interpretable AI copilot for collaborative clinical decision-making. By analyzing longitudinal electronic health records, AICare grounds dynamic risk predictions in scrutable visualizations and LLM-driven diagnostic recommendations. Through a within-subjects counterbalanced study with 16 clinicians across nephrology and obstetrics, we comprehensively evaluated AICare using objective measures (task completion time and error rate), subjective assessments (NASA-TLX, SUS, and confidence ratings), and semi-structured interviews. Our findings indicate AICare's reduced cognitive workload. Beyond performance metrics, qualitative analysis reveals that trust is actively constructed through verification, with interaction strategies diverging by expertise: junior clinicians used the system as cognitive scaffolding to structure their analysis, while experts engaged in adversarial verification to challenge the AI's logic. This work offers design implications for creating AI systems that function as transparent partners, accommodating diverse reasoning styles to augment rather t
Blind Sweep Obstetric Ultrasound (BSOU) enables scalable fetal imaging in low-resource settings by allowing minimally trained operators to acquire standardized sweep videos for automated Artificial Intelligence(AI) interpretation. However, the reliability of such AI systems depends critically on the quality of the acquired sweeps, and little is known about how deviations from the intended protocol affect downstream predictions. In this work, we present a systematic evaluation of BSOU quality and its impact on three key AI tasks: sweep-tag classification, fetal presentation classification, and placenta-location classification. We simulate plausible acquisition deviations, including reversed sweep direction, probe inversion, and incomplete sweeps, to quantify model robustness, and we develop automated quality-assessment models capable of detecting these perturbations. To approximate real-world deployment, we simulate a feedback loop in which flagged sweeps are re-acquired, showing that such correction improves downstream task performance. Our findings highlight the sensitivity of BSOU-based AI models to acquisition variability and demonstrate that automated quality assessment can pla
Clinical free-text notes contain vital patient information. They are structured into labelled sections; recognizing these sections has been shown to support clinical decision-making and downstream NLP tasks. In this paper, we advance clinical section segmentation through three key contributions. First, we curate a new de-identified, section-labeled obstetrics notes dataset, to supplement the medical domains covered in public corpora such as MIMIC-III, on which most existing segmentation approaches are trained. Second, we systematically evaluate transformer-based supervised models for section segmentation on a curated subset of MIMIC-III (in-domain), and on the new obstetrics dataset (out-of-domain). Third, we conduct the first head-to-head comparison of supervised models for medical section segmentation with zero-shot large language models. Our results show that while supervised models perform strongly in-domain, their performance drops substantially out-of-domain. In contrast, zero-shot models demonstrate robust out-of-domain adaptability once hallucinated section headers are corrected. These findings underscore the importance of developing domain-specific clinical resources and h
A growing share of the world's population is being born via assisted reproductive technology (ART), including in-vitro fertilisation (IVF). However, two concerns persist. First, ART pregnancies correlate with predictors of poor outcomes at birth--and it is unclear whether this relationship is causal. Second, the emotional and financial costs associated with ART-use might exacerbate defensive medical behaviour, where physicians intervene more than necessary to reduce the risk of adverse medical outcomes and litigation. We address the challenge of identifying the pure effect of ART-use on both maternal and infant outcomes at birth by leveraging exogenous variation in the success of ART cycles. We compare the obstetric outcomes for ART-conceived births with those of spontaneously-conceived births after a failed ART treatment. Moreover, we flexibly adjust for key confounders using double machine learning. We do this using clinical registry ART data and administrative maternal and infant data from New South Wales (NSW) between 2009-2017. We find that ART slightly decreases the risk of obstetric interventions, lowering the risk of a caesarean section and increasing the rate of spontaneou
Effective physician-patient communications in pre-diagnostic environments, and most specifically in complex and sensitive medical areas such as infertility, are critical but consume a lot of time and, therefore, cause clinic workflows to become inefficient. Recent advancements in Large Language Models (LLMs) offer a potential solution for automating conversational medical history-taking and improving diagnostic accuracy. This study evaluates the feasibility and performance of LLMs in those tasks for infertility cases. An AI-driven conversational system was developed to simulate physician-patient interactions with ChatGPT-4o and ChatGPT-4o-mini. A total of 70 real-world infertility cases were processed, generating 420 diagnostic histories. Model performance was assessed using F1 score, Differential Diagnosis (DDs) Accuracy, and Accuracy of Infertility Type Judgment (ITJ). ChatGPT-4o-mini outperformed ChatGPT-4o in information extraction accuracy (F1 score: 0.9258 vs. 0.9029, p = 0.045, d = 0.244) and demonstrated higher completeness in medical history-taking (97.58% vs. 77.11%), suggesting that ChatGPT-4o-mini is more effective in extracting detailed patient information, which is cr
Accurate fetal movement (FM) detection is essential for assessing prenatal health, as abnormal movement patterns can indicate underlying complications such as placental dysfunction or fetal distress. Traditional methods, including maternal perception and cardiotocography (CTG), suffer from subjectivity and limited accuracy. To address these challenges, we propose Contrastive Ultrasound Video Representation Learning (CURL), a novel self-supervised learning framework for FM detection from extended fetal ultrasound video recordings. Our approach leverages a dual-contrastive loss, incorporating both spatial and temporal contrastive learning, to learn robust motion representations. Additionally, we introduce a task-specific sampling strategy, ensuring the effective separation of movement and non-movement segments during self-supervised training, while enabling flexible inference on arbitrarily long ultrasound recordings through a probabilistic fine-tuning approach. Evaluated on an in-house dataset of 92 subjects, each with 30-minute ultrasound sessions, CURL achieves a sensitivity of 78.01% and an AUROC of 81.60%, demonstrating its potential for reliable and objective FM analysis. These
Despite the rapid development of AI models in medical image analysis, their validation in real-world clinical settings remains limited. To address this, we introduce a generic framework designed for deploying image-based AI models in such settings. Using this framework, we deployed a trained model for fetal ultrasound standard plane detection, and evaluated it in real-time sessions with both novice and expert users. Feedback from these sessions revealed that while the model offers potential benefits to medical practitioners, the need for navigational guidance was identified as a key area for improvement. These findings underscore the importance of early deployment of AI models in real-world settings, leading to insights that can guide the refinement of the model and system based on actual user feedback.
Eye trackers can provide visual guidance to sonographers during ultrasound (US) scanning. Such guidance is potentially valuable for less experienced operators to improve their scanning skills on how to manipulate the probe to achieve the desired plane. In this paper, a multimodal guidance approach (Multimodal-GuideNet) is proposed to capture the stepwise dependency between a real-world US video signal, synchronized gaze, and probe motion within a unified framework. To understand the causal relationship between gaze movement and probe motion, our model exploits multitask learning to jointly learn two related tasks: predicting gaze movements and probe signals that an experienced sonographer would perform in routine obstetric scanning. The two tasks are associated by a modality-aware spatial graph to detect the co-occurrence among the multi-modality inputs and share useful cross-modal information. Instead of a deterministic scanning path, Multimodal-GuideNet allows for scanning diversity by estimating the probability distribution of real scans. Experiments performed with three typical obstetric scanning examinations show that the new approach outperforms single-task learning for both
Background: Pregnancy-associated thrombotic microangiopathy (P-TMA) is rare but life-threatening. Early risk prediction before overt clinical presentation remains challenging, as the associated laboratory abnormalities are subtle, multidimensional, and frequently masked by common physiological changes such as gestational thrombocytopenia and pregnancy-related proteinuria, thus overlapping heavily with benign obstetric and renal conditions. This complexity is poorly captured by univariate or rule-based approaches; however, it is addressable by machine learning, which can extract latent, time-dependent risk signatures from longitudinal clinical tests. Methods: This retrospective study included 300 pregnancies comprising 142 P-TMA cases and 158 controls. After exclusion of identifiers and non-informative variables, 146 longitudinal laboratory predictors were retained. Participants were divided into a training cohort (80%) and a held-out test cohort (20%) using stratified sampling. Five algorithms were evaluated: logistic regression, support vector machine with radial basis function kernel, random forest, extra trees, and gradient boosting. The final model was selected by mean cross-va
While machine learning shows promise for maternal health risk prediction, clinical adoption in resource-constrained settings faces a critical barrier: lack of explainability and trust. This study presents a hybrid explainable AI (XAI) framework combining ante-hoc fuzzy logic with post-hoc SHAP explanations, validated through systematic clinician feedback. We developed a fuzzy-XGBoost model on 1,014 maternal health records, achieving 88.67% accuracy (ROC-AUC: 0.9703). A validation study with 14 healthcare professionals in Bangladesh revealed strong preference for hybrid explanations (71.4% across three clinical cases) with 54.8% expressing trust for clinical use. SHAP analysis identified healthcare access as the primary predictor, with the engineered fuzzy risk score ranking third, validating clinical knowledge integration (r=0.298). Clinicians valued integrated clinical parameters but identified critical gaps: obstetric history, gestational age, and connectivity barriers. This work demonstrates that combining interpretable fuzzy rules with feature importance explanations enhances both utility and trust, providing practical insights for XAI deployment in maternal healthcare.
Health systems are rapidly deploying large language models (LLMs) that use clinical notes for clinical decision support applications. However, modern documentation practices rely heavily on templates, copy--paste shortcuts, and auto-populated fields, producing extensive duplicated text (``note bloat'') that dilutes clinically meaningful signal and substantially increases the computational cost of LLM use. We introduce TRACE, a scalable preprocessing pipeline that removes note bloat by leveraging EHR attribution metadata to identify templated and copied content and applying frequency-based deduplication when metadata are unavailable. We evaluated TRACE across four real--world clinical cohorts spanning liver transplantation, obstetrics, and inpatient care (5.3 million notes) using blinded physician review and downstream modeling tasks. TRACE removed 47.3% of chart text while preserving performance for information extraction and clinical outcome prediction. At a large academic medical center, this reduction corresponds to an estimated $9.5 million annual decrease in LLM inference costs assuming one query per encounter. These findings show how underutilized EHR metadata can enable more
Approximately 10% of newborns require assistance to initiate breathing at birth, and around 5% need ventilation support. Fetal heart rate (FHR) monitoring plays a crucial role in assessing fetal well-being during prenatal care, enabling the detection of abnormal patterns and supporting timely obstetric interventions to mitigate fetal risks during labor. Applying artificial intelligence (AI) methods to analyze large datasets of continuous FHR monitoring episodes with diverse outcomes may offer novel insights into predicting the risk of needing breathing assistance or interventions. Recent advances in wearable FHR monitors have enabled continuous fetal monitoring without compromising maternal mobility. However, sensor displacement during maternal movement, as well as changes in fetal or maternal position, often lead to signal dropout, resulting in gaps in recorded FHR data. Such missing data limits the extraction of meaningful insights and complicates automated (AI-based) analysis. Traditional approaches to handling missing data, such as simple interpolation techniques, often fail to preserve the spectral characteristics of the signals. In this paper, we propose a masked transformer-
Ultrasound is widely used in obstetric care due to its safety, accessibility, and real-time imaging. However, interpretation remains operator-dependent and susceptible to noise and artifacts. Deep learning models have shown strong performance to solve these problem, but they typically require large annotated datasets that are difficult to obtain in clinical ultrasound. Foundation models (FMs) offer an alternative, using a large number of ultrasound images to learn transferable representations that can generalize with limited labeled data. This work presents a comprehensive benchmark of ultrasound-specific FMs for fetal plane classification. We evaluated four ultrasound FMs (USFM, MOFO, UltraSAM, FetalCLIP) against two CNN baselines (ResNet50, EfficientNet-V2) and a ViT (DINOv3) pretrained on natural images. We trained all models under two complementary settings: full fine-tuning and linear probing with a frozen encoder. All models were trained using 5-fold patient-level cross-validation on a Spanish fetal ultrasound dataset and tested on both in-domain data and an external African cohort to assess cross-population generalization. We found that FetalCLIP achieved the best results in
The fragmentation of obstetric information across electronic health record modules, device repositories, and laboratory systems, as it is common in hospitals, hinders both intrapartum care and reproducible research. In this work, we present a practical blueprint for transforming heterogeneous peripartum records into computable, queryable assets by designing and prototyping a unified peripartum relational database with natural-language-to-SQL (NL2SQL) capabilities at the Obstetrics Clinic of Udine University Hospital. Requirements were co-defined with clinicians and formalized as an Entity-Relationship diagram, from which the logical schema and SQL implementation of the database were then derived. The latter integrates heterogeneous sources to connect maternal anamnestic and longitudinal history, current-pregnancy findings, intrapartum course, and delivery and neonatal outcomes. The NL2SQL layer enables clinicians to pose natural-language queries to the system, lowering barriers to audit and exploratory analysis.
Placenta Accreta Spectrum (PAS) is a life-threatening obstetric complication involving abnormal placental invasion into the uterine wall. Early and accurate prenatal diagnosis is essential to reduce maternal and neonatal risks. This study aimed to develop and validate a deep learning framework that enhances PAS detection by integrating multiple imaging modalities. A multimodal deep learning model was designed using an intermediate feature-level fusion architecture combining 3D Magnetic Resonance Imaging (MRI) and 2D Ultrasound (US) scans. Unimodal feature extractors, a 3D DenseNet121-Vision Transformer for MRI and a 2D ResNet50 for US, were selected after systematic comparative analysis. Curated datasets comprising 1,293 MRI and 1,143 US scans were used to train the unimodal models and paired samples of patient-matched MRI-US scans was isolated for multimodal model development and evaluation. On an independent test set, the multimodal fusion model achieved superior performance, with an accuracy of 92.5% and an Area Under the Receiver Operating Characteristic Curve (AUC) of 0.927, outperforming the MRI-only (82.5%, AUC 0.825) and US-only (87.5%, AUC 0.879) models. Integrating MRI an
Prenatal maternal stress (PS) is a risk factor for adverse offspring neurodevelopment. Heart rate variability (HRV) complexity provides a non-invasive marker of maternal autonomic regulation and may be influenced by mind--body interventions such as Yoga. In this quasi-randomized controlled trial, 28 chronically stressed pregnant women were followed from the second trimester until birth: 14 participated in weekly Hatha Yoga with electrocardiogram (ECG) recordings, and 14 received standard obstetric care with monthly ECGs. Group allocation was based on availability, with participants unaware of their assignment at enrollment. HRV complexity was assessed first with Sample Entropy and Entropy Rate and then expanded to 94 HRV metrics spanning temporal, frequency, nonlinear, and information-theoretical domains. All metrics were covariate-adjusted (maternal age, BMI, gestational age), standardized, and analyzed using timepoint-specific principal component analysis (PCA). From this, a unified HRV index was derived. Analyses revealed that HRV metric relationships changed dynamically across pregnancy, with PCA loadings shifting from frequency toward complexity measures in late gestation. The
Digitization of medical records often relies on smartphone photographs of printed reports, producing images degraded by blur, shadows, and other noise. Conventional OCR systems, optimized for clean scans, perform poorly under such real-world conditions. This study evaluates compact multimodal language models as privacy-preserving alternatives for transcribing noisy clinical documents. Using obstetric ultrasound reports written in regionally inflected medical English common to Indian healthcare settings, we compare eight systems in terms of transcription accuracy, noise sensitivity, numeric accuracy, and computational efficiency. Compact multimodal models consistently outperform both classical and neural OCR pipelines. Despite higher computational costs, their robustness and linguistic adaptability position them as viable candidates for on-premises healthcare digitization.
Segmenting fetal head structures from prenatal ultrasound remains a practical bottleneck in obstetric imaging. The current state-of-the-art baseline, proposed alongside the published dataset, adapts the Segment Anything Model with per-class Dice and Lovász losses but still depends on bounding-box prompts at test time. We build a prompt-free pipeline on top of YOLO26-Seg that jointly detects and segments three structures, Brain, Cavum Septi Pellucidi (CSP), and Lateral Ventricles (LV), in a single forward pass. Three modifications are central to our approach: (i) a composite BCE-Dice-Lovász segmentation loss with inverse-frequency class weighting, injected into the YOLO26 training loop via runtime monkey-patching; (ii) domain-guided copy-paste augmentation that transplants minority-class structures while respecting their anatomical location relative to the brain boundary; and (iii) inter-patient stratified splitting to prevent data leakage. On 575 held-out test images, the composite loss variant reaches a mean Dice coefficient of 0.9253, exceeding the baseline (0.9012) by 2.68 percentage points, despite reporting over three foreground classes only, whereas the baseline's reported me
Access to obstetric ultrasound is often limited in low-resource settings, particularly in rural areas of low- and middle-income countries. This work proposes a human-in-the-loop artificial intelligence (AI) system designed to assist midwives in acquiring diagnostically relevant fetal images using blind sweep protocols. The system incorporates a classification model along with a web-based platform for asynchronous specialist reviews. By identifying key frames in blind sweep studies, the AI system allows specialists to concentrate on interpretation rather than having to review entire videos. To evaluate its performance, blind sweep videos captured by a small group of soft-trained midwives using a low-cost Point-of-Care Ultrasound (POCUS) device were analyzed. The system demonstrated promising results in identifying standard fetal planes from sweeps made by non-experts. A field evaluation indicated good usability and a low cognitive workload, suggesting that it has the potential to expand access to prenatal imaging in underserved regions.