BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and detailed TRT dose calculation. METHODS: The novel application egs_mird is introduced, including its structure and variation reduction approaches. A new egs++ source class egs_internal_source and a modified version of egs_radionuclide_source are described. The new code is compared to other MC calculations of S-value kernels, along with self-validation using the electron Fano test. Full patient prostate 177Lu TRT cancer treatment simulations are performed using a single set of patient DICOM CT and [18F]-DCFPyL PET data. RESULTS: Good agreement is found between S-value kernels calculated using egs_mird and those found in the literature. The Fano test is satisfied to 0.1%. Patient prostate, rectum, bone marrow, and bladder dose volume histogram results did not vary significantly when using th
This study presents the first clinical integration and experimental demonstration of a nozzle-mounted Compton camera prompt gamma imaging (PGI) system for in vivo proton range verification. Four position-sensitive solid-state Compton camera modules, each containing four cadmium zinc telluride (CdZnTe) detector crystals, were integrated into a modified range shifter mounted directly on the treatment nozzle of a clinical proton therapy gantry. This compact fixed-geometry configuration maintained alignment with the proton beam axis throughout irradiation and enabled stable synchronized data acquisition during pencil-beam scanning delivery. The system was evaluated under realistic clinical proton beam delivery conditions using single-energy and spread-out Bragg peak (SOBP) irradiations at gantry angles of 90° and 270°, delivered doses of 2 Gy and 7.5 Gy, and controlled distal range shifts of up to 10 mm. Prompt gamma events were reconstructed into three-dimensional emission distributions using a physics-based Compton scatter reconstruction framework. The system operated reliably during all irradiations and produced reproducible prompt-gamma localization across repeated measurements. Re
This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in nuclear astrophysics experiments at CERN, is being optimized for detecting and imaging 478 keV gamma-rays, critical for accurate BNCT dosimetry. Detailed Monte Carlo simulations were used to optimize the i-TED detector configuration and enhance its performance in the challenging radiation environment typical of BNCT. Additionally, advanced 3D image reconstruction algorithms, including a combination of back-projection and List-Mode Maximum Likelihood Expectation Maximization (LM-MLEM), are implemented and validated through simulations. Preliminary experimental tests at the Institut Laue-Langevin (ILL) demonstrate the potential of i-TED in a clinical setting, with ongoing experiments focusing on improving imaging capabilities in realistic BNCT conditions.
Robot-Assisted Therapy (RAT) has successfully been used in Human Robot Interaction (HRI) research by including social robots in health-care interventions by virtue of their ability to engage human users in both social and emotional dimensions. Robots used for these tasks must be designed with several user groups in mind, including both individuals receiving therapy and care professionals responsible for the treatment. These robots must also be able to perceive their context of use, recognize human actions and intentions, and follow the therapeutic goals to perform meaningful and personalized treatment. Effective interactions require for robots to be capable of coordinated, timely behavior in response to social cues. This means being able to estimate and predict levels of engagement, attention, intentionality and emotional state during human-robot interactions. An additional challenge for social robots in therapy and care is the wide range of needs and conditions the different users can have during their interventions, even if they may share the same pathologies their current requirements and the objectives of their therapies can varied extensively. Therefore, it becomes crucial for
Spectral imaging is a fundamental diagnostic technique with widespread application. Conventional spectral imaging approaches have intrinsic limitations on spatial and spectral resolutions due to the physical components they rely on. To overcome these physical limitations, in this paper, we develop a novel multi-spectral imaging modality that enables higher spatial and spectral resolutions. In the developed computational imaging modality, we exploit a diffractive lens, such as a photon sieve, for both dispersing and focusing the optical field, and achieve measurement diversity by changing the focusing behavior of this lens. Because the focal length of a diffractive lens is wavelength-dependent, each measurement is a superposition of differently blurred spectral components. To reconstruct the individual spectral images from these superimposed and blurred measurements, model-based fast reconstruction algorithms are developed with deep and analytical priors using alternating minimization and unrolling. Finally, the effectiveness and performance of the developed technique is illustrated for an application in astrophysical imaging under various observation scenarios in the extreme ultrav
We aim to characterize the U-band variability of young brown dwarfs in the Taurus Molecular Cloud and discuss its origin. We used the XMM-Newton Extended Survey of the Taurus Molecular Cloud, where a sample of 11 young bona fide brown dwarfs (spectral type later than M6) were observed simultaneously in X-rays with XMM-Newton and in the U-band with the XMM-Newton Optical/UV Monitor (OM). We obtained upper limits to the U-band emission of 10 brown dwarfs (U>19.6-20.6 mag), whereas 2MASSJ04141188+2811535 was detected in the U-band. Remarkably, the magnitude of this brown dwarf increased regularly from U~19.5 mag at the beginning of the observation, peaked 6h later at U~18.4 mag, and then decreased to U~18.65 mag in the next 2h. The first OM U-band measurement is consistent with the quiescent level observed about one year later thanks to ground follow-up observations. This brown dwarf was not detected in X-rays by XMM-Newton during the OM observation. We discuss the possible sources of U-band variability for this young brown dwarf, namely a magnetic flare, non-steady accretion onto the substellar surface, and rotational modulation of a hot spot. We conclude that this event is relate
The $^{10}$B isotope has been almost exclusively used in the neutron-capture radiation therapy (NCT) of cancer for decades. We have identified two other nuclides suitable for the radiotherapy, which have ca.10 times larger cross section of absorption for neutrons and emit heavy charged particles. This would provide several key advantages for potential NCT, such as the possibility to use either a lower nuclide concentration in the target tissues, or a lower neutron irradiation flux. By detecting the characteristic $γ$ radiation from the spontaneous decay of the radionuclides, one can image and control their accumulation. These advantages could be critical for the revival of the NCT as a safer, more efficient and more widely used cancer therapy.
Selective accumulation of B-10 compound in tumour tissue is a fundamental condition for the achievement of BNCT (Boron Neutron Capture Therapy), since the effectiveness of therapy irradiation derives just from neutron capture reaction of B-10. Hence, the determination of the B-10 concentration ratio, between tumour and healthy tissue, and a control of this ratio, during the therapy, are essential to optimise the effectiveness of the BNCT, which it is known to be based on the selective uptake of B-10 compound. In this work, experimental methods are proposed and evaluated for the determination in vivo of B-10 compound in biological samples, in particular based on neutron radiography and gammaray spectroscopy by telescopic system. Measures and Monte Carlo calculations have been performed to investigate the possibility of executing imaging of the 10B distribution, both by radiography with thermal neutrons, using 6LiF/ZnS:Ag scintillator screen and a CCD camera, and by spectroscopy, based on the revelation of gamma-ray reaction products from B-10 and the H. A rebuilding algorithm has been implemented. The present study has been done for the standard case of B-10 uptake, as well as for p
Apparent excesses in early-solar $^{26}$Al, $^{36}$Cl, $^{41}$Ca, and $^{60}$Fe disappear if one accounts for ejecta from massive-star winds concentrated into dense phases of the ISM in star-forming regions. The removal of apparent excesses is evident when wind yields from Wolf-Rayet stars are included in the plot of radionuclide abundances vs. mean life. The resulting trend indicates that the solar radionuclides were inherited from parental molecular clouds with a characteristic residence time of 10$^8$ years. This residence time is of the same order as the present-day timescale for conversion of molecular cloud material into stars. The concentrations of these extinct isotopes in the early solar system need not signify injection from unusual proximal stellar sources, but instead are well explained by normal concentrations in average star-forming clouds. The results imply that the efficiency of capture is greater for stellar winds than for supernova ejecta proximal to star-forming regions.
Eye tracking has emerged as a powerful tool for examining visual perception and search strategies in various domains, including medicine. While it is relatively straightforward to apply in 2D settings, its use in 3D medical imaging remains challenging and not yet well explored. This gap is particularly relevant for radiology, where volumetric images such as computed tomography (CT) scans are routinely read by medical experts. Radiologists typically interpret these images by navigating through hundreds of 2D slices, most often viewed in the axial projection. A taxonomy of eye movement data during navigation through a CT volume could be valuable to understand how radiologists approach diagnostic tasks. As an example of the derived taxonomy, we asked two radiologists to search abdominal CTs of the pancreas. We collect eye tracking data and align eye gaze movements with slice navigation to visualize the representation of the pancreas through volume and analyze clinicians' gaze behavior in both space and time.
As the data volume of astronomical imaging surveys rapidly increases, traditional methods for image anomaly detection, such as visual inspection by human experts, are becoming impractical. We introduce a machine-learning-based approach to detect poor-quality exposures in large imaging surveys, with a focus on the DECam Legacy Survey (DECaLS) in regions of low extinction (i.e., $E(B-V)<0.04$). Our semi-supervised pipeline integrates a vision transformer (ViT), trained via self-supervised learning (SSL), with a k-Nearest Neighbor (kNN) classifier. We train and validate our pipeline using a small set of labeled exposures observed by surveys with the Dark Energy Camera (DECam). A clustering-space analysis of where our pipeline places images labeled in ``good'' and ``bad'' categories suggests that our approach can efficiently and accurately determine the quality of exposures. Applied to new imaging being reduced for DECaLS Data Release 11, our pipeline identifies 780 problematic exposures, which we subsequently verify through visual inspection. Being highly efficient and adaptable, our method offers a scalable solution for quality control in other large imaging surveys.
Stuttering, also called stammering, is a communication disorder that breaks the continuity of the speech. This program of work is an attempt to develop automatic recognition procedures to assess stuttered dysfluencies and use these assessments to filter out speech therapies for an individual. Stuttering may be in the form of repetitions, prolongations or abnormal stoppages of sounds and syllables. Our system aims to help stutterers by diagnosing the severity and type of stutter and also by suggesting appropriate therapies for practice by learning the correlation between stutter descriptors and the effectiveness of speech therapies on them. This paper focuses on the implementation of a stutter diagnosis agent using Gated Recurrent CNN on MFCC audio features and therapy recommendation agent using SVM. It also presents the results obtained and various key findings of the system developed.
Color quantization represents an image using a fraction of its original number of colors while only minimally losing its visual quality. The $k$-means algorithm is commonly used in this context, but has mostly been applied in the machine-based RGB colorspace composed of the three primary colors. However, some recent studies have indicated its improved performance in human perception-based colorspaces. We investigated the performance of $k$-means color quantization at four quantization levels in the RGB, CIE-XYZ, and CIE-LUV/CIE-HCL colorspaces, on 148 varied digital images spanning a wide range of scenes, subjects and settings. The Visual Information Fidelity (VIF) measure numerically assessed the quality of the quantized images, and showed that in about half of the cases, $k$-means color quantization is best in the RGB space, while at other times, and especially for higher quantization levels ($k$), the CIE-XYZ colorspace is where it usually does better. There are also some cases, especially at lower $k$, where the best performance is obtained in the CIE-LUV colorspace. Further analysis of the performances in terms of the distributions of the hue, chromaticity and luminance in an
Robot-assisted therapy is an emerging form of therapy for autistic children, although designing effective robot behaviors is a challenge for effective implementation of such therapy. A series of usability tests assessed trends in the effectiveness of modelling a robot's facial expressions on realistic facial expressions and of adding peripherals enabling child-led control of emotion learning activities with autistic children. Nineteen autistic children interacted with a small humanoid robot and an adult therapist in several emotion-learning activities that featured realistic facial expressions modelled on either a pre-existing database or live facial mirroring, and that used peripherals (tablets or tangible 'squishies') to enable child-led activities. Both types of realistic facial expressions by the robot were less effective than exaggerated expressions, with the mirroring being unintuitive for children. The tablet was usable but required more feedback and lower latency, while the tactile tangibles were engaging aids.
When conducting large-scale studies that collect brain MR images from multiple facilities, the impact of differences in imaging equipment and protocols at each site cannot be ignored, and this domain gap has become a significant issue in recent years. In this study, we propose a new low-dimensional representation (LDR) acquisition method called style encoder adversarial domain adaptation (SE-ADA) to realize content-based image retrieval (CBIR) of brain MR images. SE-ADA reduces domain differences while preserving pathological features by separating domain-specific information from LDR and minimizing domain differences using adversarial learning. In evaluation experiments comparing SE-ADA with recent domain harmonization methods on eight public brain MR datasets (ADNI1/2/3, OASIS1/2/3/4, PPMI), SE-ADA effectively removed domain information while preserving key aspects of the original brain structure and demonstrated the highest disease search accuracy.
Purpose: To demonstrate the feasibility and performance of a fully automated deep learning framework to estimate myocardial strain from short-axis cardiac magnetic resonance tagged images. Methods and Materials: In this retrospective cross-sectional study, 4508 cases from the UK Biobank were split randomly into 3244 training and 812 validation cases, and 452 test cases. Ground truth myocardial landmarks were defined and tracked by manual initialization and correction of deformable image registration using previously validated software with five readers. The fully automatic framework consisted of 1) a convolutional neural network (CNN) for localization, and 2) a combination of a recurrent neural network (RNN) and a CNN to detect and track the myocardial landmarks through the image sequence for each slice. Radial and circumferential strain were then calculated from the motion of the landmarks and averaged on a slice basis. Results: Within the test set, myocardial end-systolic circumferential Green strain errors were -0.001 +/- 0.025, -0.001 +/- 0.021, and 0.004 +/- 0.035 in basal, mid, and apical slices respectively (mean +/- std. dev. of differences between predicted and manual stra
In this paper, we discuss the possibility of imaging molecular orbitals from photoelectron spectra obtained via Laser Induced Electron Diffraction (LIED) in linear molecules. This is an extension of our work published recently in Physical Review A \textbf{94}, 023421 (2016) to the case of the HOMO-1 orbital of the carbon dioxide molecule. We show that such an imaging technique has the potential to image molecular orbitals at different internuclear distances in a sub-femtosecond time scale and with a resolution of a fraction of an Angström.
With the proliferation of image-based applications in various domains, the need for accurate and interpretable image similarity measures has become increasingly critical. Existing image similarity models often lack transparency, making it challenging to understand the reasons why two images are considered similar. In this paper, we propose the concept of explainable image similarity, where the goal is the development of an approach, which is capable of providing similarity scores along with visual factual and counterfactual explanations. Along this line, we present a new framework, which integrates Siamese Networks and Grad-CAM for providing explainable image similarity and discuss the potential benefits and challenges of adopting this approach. In addition, we provide a comprehensive discussion about factual and counterfactual explanations provided by the proposed framework for assisting decision making. The proposed approach has the potential to enhance the interpretability, trustworthiness and user acceptance of image-based systems in real-world image similarity applications. The implementation code can be found in https://github.com/ioannislivieris/Grad_CAM_Siamese.git.
For acute ischemic stroke (AIS) patients with large vessel occlusions, clinicians must decide if the benefit of mechanical thrombectomy (MTB) outweighs the risks and potential complications following an invasive procedure. Pre-treatment computed tomography (CT) and angiography (CTA) are widely used to characterize occlusions in the brain vasculature. If a patient is deemed eligible, a modified treatment in cerebral ischemia (mTICI) score will be used to grade how well blood flow is reestablished throughout and following the MTB procedure. An estimation of the likelihood of successful recanalization can support treatment decision-making. In this study, we proposed a fully automated prediction of a patient's recanalization score using pre-treatment CT and CTA imaging. We designed a spatial cross attention network (SCANet) that utilizes vision transformers to localize to pertinent slices and brain regions. Our top model achieved an average cross-validated ROC-AUC of 77.33 $\pm$ 3.9\%. This is a promising result that supports future applications of deep learning on CT and CTA for the identification of eligible AIS patients for MTB.
Lensless illumination single-pixel imaging with a multicore fiber (MCF) is a computational imaging technique that enables potential endoscopic observations of biological samples at cellular scale. In this work, we show that this technique is tantamount to collecting multiple symmetric rank-one projections (SROP) of an interferometric matrix--a matrix encoding the spectral content of the sample image. In this model, each SROP is induced by the complex sketching vector shaping the incident light wavefront with a spatial light modulator (SLM), while the projected interferometric matrix collects up to $O(Q^2)$ image frequencies for a $Q$-core MCF. While this scheme subsumes previous sensing modalities, such as raster scanning (RS) imaging with beamformed illumination, we demonstrate that collecting the measurements of $M$ random SLM configurations--and thus acquiring $M$ SROPs--allows us to estimate an image of interest if $M$ and $Q$ scale log-linearly with the image sparsity level This demonstration is achieved both theoretically, with a specific restricted isometry analysis of the sensing scheme, and with extensive Monte Carlo experiments. On a practical side, we perform a single ca