For getting good sleep quality, an improved approach of new mattress development based on the pressure sensors for body-contouring uniform support is proposed in this paper. This method solved the problems of innerspring mattresses that cannot allow body-contouring uniform support, and foam mattresses that cannot provide everybody equal comfort from the same mattress. By the buried pressure sensor array and actuator array in foam layer of a mattress, both are connected to a controller to generate the pressure distribution mapping of a human body on the mattress, then from the data of this mapping, some of the actuators are driven up or down by the controller to generate a body-contouring uniform support. By the aid of mathematical morphology algorithms, user can also choose a different support mode by another wireless controller with touch-screen to accommodate personal favorite firmness of the mattress and to take his tensed mood and pressure off with good sleep until daylight. Moreover, some other homecare functions, such as temperature measurement, sleep on posture correction and fall down prevention, can approach by additional hardware and software as user requirement in the fu
Winkler's mattress model is often used as a simplified model to understand how a thin elastic layer, such as a coating, deforms when subject to a distributed normal load: the deformation of the layer is assumed proportional to the applied normal load. This simplicity means that the Winkler model has found a wide range of applications from soft matter to geophysics. However, in the limit of an incompressible elastic layer the model predicts infinite resistance to deformation, and hence breaks down. Since many of the thin layers used in applications are elastomeric, and hence close to incompressible, we consider the question of when the Winkler model is appropriate for such layers. We formally derive a model that interpolates between the Winkler and incompressible limits for thin elastic layers, and illustrate this model by detailed consideration of two example problems: the point indentation of a coated elastomeric layer and self-sustained lift in soft elastohydrodynamic lubrication. We find that the applicability (or otherwise) of the Winkler model is not determined by the value of the Poisson ratio alone, but by a compressibility parameter that combines the Poisson ratio with a me
Recent experiments (Zhu & Granick (2001) Phys. Rev. Lett. 87 096105) have measured a large shear dependent fluid slip at partially wetting fluid-solid surfaces. We present a simple model for such slip, motivated by the recent observations of nanobubbles on hydrophobic surfaces. The model considers the dynamic response of bubbles to change in hydrodynamic pressure due to the oscillation of a solid surface. Both the compression and diffusion of gas in the bubbles decrease the force on the oscillating surface by a ``leaking mattress'' effect, thereby creating an apparent shear-dependent slip. With bubbles similar to those observed by atomic force microscopy to date, the model is found to lead to force decreases consistent with the experimental measurements of Zhu & Granick.
Laminar flow over a bubble mattress is expected to experience a significant reduction in friction since the individual surfaces of the bubbles are shear-free. However, if the bubbles are sufficiently curved, their protrusion into the fluid and along the flow direction can lead to an increase in friction as was recently demonstrated experimentally and computationally. We provide in this paper a simple model for this result. We consider a shear flow at low Reynolds number past a two-dimensional array of bubbles, and calculate analytically the effective slip length of the surface as function of the bubble geometry in the dilute limit. Our model is able to reproduce quantitatively the relationship between effective friction and bubble geometry obtained in numerical computations, and in particular: (a) The asymmetry in friction between convex and concave bubbles, and (b) the existence of a geometric transition from reduced to enhanced friction at a critical bubble protrusion angle.
We consider the effective hydrophobicity of a periodically grooved surface immersed in liquid, with trapped shear-free bubbles protruding between the no-slip ridges at a $π/2$ contact angle. Specifically, we carry out a singular-perturbation analysis in the limit $ε\ll1$ where the bubbles are closely spaced, finding the effective slip length (normalised by the bubble radius) for longitudinal flow along the the ridges as $π/{\sqrt{2ε}}-(12/π)\ln 2 + (13π/24)\sqrt{2ε}+ o(\sqrtε)$, the small parameter $ε$ being the planform solid fraction. The square-root divergence highlights the strong hydrophobic character of this configuration; this leading singular term (along with the third term) follows from a local lubrication-like analysis of the gap regions between the bubbles, together with general matching considerations and a global conservation relation. The $O(1)$ constant term is found by matching with a leading-order solution in the "outer'" region, where the bubbles appear to be touching. We find excellent agreement between our slip-length formula and a numerical scheme recently derived using a "unified-transform" method (D. Crowdy, IMA J. Appl. Math., 80 1902, 2015). The comparison
DemandLens demonstrates an innovative Prophet based forecasting model for the mattress-in-a-box industry, incorporating COVID-19 metrics and SKU-specific hyperparameter optimization. This industry has seen significant growth of E-commerce players in the recent years, wherein the business model majorly relies on outsourcing Mattress manufacturing and related logistics and supply chain operations, focusing on marketing the product and driving conversions through Direct-to-Consumer sales channels. Now, within the United States, there are a limited number of Mattress contract manufacturers available, and hence, it is important that they manage their raw materials, supply chain, and, inventory intelligently, to be able to cater maximum Mattress brands. Our approach addresses the critical need for accurate Sales Forecasting in an industry that is heavily dependent on third-party Contract Manufacturing. This, in turn, helps the contract manufacturers to be prepared, hence, avoiding bottleneck scenarios, and aiding them to source raw materials at optimal rates. The model demonstrates strong predictive capabilities through SKU-specific Hyperparameter optimization, offering the Contract Manu
Bed-based pressure-sensitive mats (PSMs) offer a non-intrusive way of monitoring patients during sleep. We focus on four-way sleep position classification using data collected from a PSM placed under a mattress in a sleep clinic. Sleep positions can affect sleep quality and the prevalence of sleep disorders, such as apnea. Measurements were performed on patients with suspected sleep disorders referred for assessments at a sleep clinic. Training deep learning models can be challenging in clinical settings due to the need for large amounts of labeled data. To overcome the shortage of labeled training data, we utilize transfer learning to adapt pre-trained deep learning models to accurately estimate sleep positions from a low-resolution PSM dataset collected in a polysomnography sleep lab. Our approach leverages Vision Transformer models pre-trained on ImageNet using masked autoencoding (ViTMAE) and a pre-trained model for human pose estimation (ViTPose). These approaches outperform previous work from PSM-based sleep pose classification using deep learning (TCN) as well as traditional machine learning models (SVM, XGBoost, Random Forest) that use engineered features. We evaluate the p
Prolonged seated activity is increasingly common in modern environments, raising concerns around musculoskeletal health, ergonomics, and the design of responsive interactive systems. Existing posture sensing methods such as vision-based or wearable approaches face limitations including occlusion, privacy concerns, user discomfort, and restricted deployment flexibility. We introduce ChairPose, the first full body, wearable free seated pose estimation system that relies solely on pressure sensing and operates independently of chair geometry. ChairPose employs a two stage generative model trained on pressure maps captured from a thin, chair agnostic sensing mattress. Unlike prior approaches, our method explicitly incorporates chair morphology into the inference process, enabling accurate, occlusion free, and privacy preserving pose estimation. To support generalization across diverse users and chairs, we introduce a physics driven data augmentation pipeline that simulates realistic variations in posture and seating conditions. Evaluated across eight users and four distinct chairs, ChairPose achieves a mean per joint position error of 89.4 mm when both the user and the chair are unseen
Lower-Limb Fractures (LLF) are a major health concern for older adults, often leading to reduced mobility and prolonged recovery, potentially impairing daily activities and independence. During recovery, older adults frequently face social isolation and functional decline, complicating rehabilitation and adversely affecting physical and mental health. Multi-modal sensor platforms that continuously collect data and analyze it using machine-learning algorithms can remotely monitor this population and infer health outcomes. They can also alert clinicians to individuals at risk of isolation and decline. This paper presents a new publicly available multi-modal sensor dataset, MAISON-LLF, collected from older adults recovering from LLF in community settings. The dataset includes data from smartphone and smartwatch sensors, motion detectors, sleep-tracking mattresses, and clinical questionnaires on isolation and decline. The dataset was collected from ten older adults living alone at home for eight weeks each, totaling 560 days of 24-hour sensor data. For technical validation, supervised machine-learning and deep-learning models were developed using the sensor and clinical questionnaire d
Accurately predicting the 3D human posture and the pressure exerted on the body for people resting in bed, visualized as a body mesh (3D pose & shape) with a 3D pressure map, holds significant promise for healthcare applications, particularly, in the prevention of pressure ulcers. Current methods focus on singular facets of the problem -- predicting only 2D/3D poses, generating 2D pressure images, predicting pressure only for certain body regions instead of the full body, or forming indirect approximations to the 3D pressure map. In contrast, we introduce BodyMAP, which jointly predicts the human body mesh and 3D applied pressure map across the entire human body. Our network leverages multiple visual modalities, incorporating both a depth image of a person in bed and its corresponding 2D pressure image acquired from a pressure-sensing mattress. The 3D pressure map is represented as a pressure value at each mesh vertex and thus allows for precise localization of high-pressure regions on the body. Additionally, we present BodyMAP-WS, a new formulation of pressure prediction in which we implicitly learn pressure in 3D by aligning sensed 2D pressure images with a differentiable 2D
Body weight, as an essential physiological trait, is of considerable significance in many applications like body management, rehabilitation, and drug dosing for patient-specific treatments. Previous works on the body weight estimation task are mainly vision-based, using 2D/3D, depth, or infrared images, facing problems in illumination, occlusions, and especially privacy issues. The pressure mapping mattress is a non-invasive and privacy-preserving tool to obtain the pressure distribution image over the bed surface, which strongly correlates with the body weight of the lying person. To extract the body weight from this image, we propose a deep learning-based model, including a dual-branch network to extract the deep features and pose features respectively. A contrastive learning module is also combined with the deep-feature branch to help mine the mutual factors across different postures of every single subject. The two groups of features are then concatenated for the body weight regression task. To test the model's performance over different hardware and posture settings, we create a pressure image dataset of 10 subjects and 23 postures, using a self-made pressure-sensing bedsheet.
Mechanical shock is a common occurrence in various settings, there are two different scenarios for shock protection: catastrophic protection (e.g. car collisions and falls) and routine protection (e.g. shoe soles and shock absorbers for car seats). The former protects against one-time events, the latter against periodic shocks and loads. Common shock absorbers based on plasticity and fracturing materials are suitable for the former, while our focus is on the latter, where elastic structures are useful. Improved elastic materials protecting against shock can be used in applications such as automotive suspension, furniture like sofas and mattresses, landing gear systems, etc. Materials offering optimal protection against shock have a highly non-linear elastic response: their reaction force needs to be as close as possible to constant with respect to deformation. In this paper, we use shape optimization and topology search to design 2D families of microstructures approximating the ideal behavior across a range of deformations, leading to superior shock protection. We present an algorithmic pipeline for the optimal design of such families combining differentiable nonlinear homogenizati
Understanding user intentions is essential for improving product recommendations, navigation suggestions, and query reformulations. However, user intentions can be intricate, involving multiple sessions and attribute requirements connected by logical operators such as And, Or, and Not. For instance, a user may search for Nike or Adidas running shoes across various sessions, with a preference for purple. In another example, a user may have purchased a mattress in a previous session and is now looking for a matching bed frame without intending to buy another mattress. Existing research on session understanding has not adequately addressed making product or attribute recommendations for such complex intentions. In this paper, we present the task of logical session complex query answering (LS-CQA), where sessions are treated as hyperedges of items, and we frame the problem of complex intention understanding as an LS-CQA task on an aggregated hypergraph of sessions, items, and attributes. This is a unique complex query answering task with sessions as ordered hyperedges. We also introduce a new model, the Logical Session Graph Transformer (LSGT), which captures interactions among items a
Recently, a new bi-layer dressing was proposed by Urgo RID to reduce the healing time of pressure ulcers (PU). This dressing was numerically evaluated in previously published work. In the current work, the influence on the maximal shear strains of modelling parameters such as the dressing local geometry, the pressure applied by the gauze inside the wound, the wound deepness, and the mattress stiffness, was assessed. A sensitivity analysis was performed on these four parameters. Among all experiments, the mean maximal Green--Lagrange shear strain was 0.29. The gauze pressure explained 60% of the model response in terms of the volume of tissues under strains of 0.3, while the wound deepness explained 28%. The mattress had a significant, but low impact, whereas the dressing local geometry had no significant impact. As expected, the wound deepness was one of the most influential parameters. The gauze turned out to be more significant than expected. This may be explained by the large range of values chosen for this study. The results should be extended to more subjects, but still suggest that the gauze is a parameter that might not be neglected. Care should also be taken in clinical pra
Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Current OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bondselective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect, achieving label-free bond-selective 3D sectioned imaging of highly scattering samples. We first demonstrate BS-FF-OCT imaging of 1 μm PMMA beads embedded in agarose gel. Next, we then show 3D hyperspectral imaging of polypropylene fiber mattress from a standard surgical mask. We then demonstrate BS-FFOCT imaging on biological samples, including cancer cell spheroids and C. elegans. Using an alternative pulse timing configuration, we finally demonstrate the capability of BS-FF-OCT on a bulky and highly scattering 150 μm thick mouse brain slice.
In the 21st century, sending babies or children to daycare centres has become more and more common among young guardians. The balance between full-time work and child care is increasingly challenging nowadays. In Malaysia, thousands of child abuse cases have been reported from babysitting centres every year, which indeed triggers the anxiety and stress of the guardians. Hence, this paper proposes to construct a remote baby surveillance system with radio-frequency identification (RFID) and global positioning system (GPS) tracking. With the incorporation of the Internet of Things (IoT), a sensor-based microcontroller is used to detect the conditions of the baby as well as the surrounding environment and then display the real-time data as well as notifications to alert the guardians via a mobile application. These conditions include the crying and waking of the baby, as well as temperature, the mattress's wetness, and moving objects around the baby. In addition, RFID and GPS location tracking are implemented to ensure the safety of the baby, while white noise is used to increase the comfort of the baby. In the end, a prototype has been successfully developed for functionality and reli
Contact pressure between the human body and its surroundings has important implications. For example, it plays a role in comfort, safety, posture, and health. We present a method that infers contact pressure between a human body and a mattress from a depth image. Specifically, we focus on using a depth image from a downward facing camera to infer pressure on a body at rest in bed occluded by bedding, which is directly applicable to the prevention of pressure injuries in healthcare. Our approach involves augmenting a real dataset with synthetic data generated via a soft-body physics simulation of a human body, a mattress, a pressure sensing mat, and a blanket. We introduce a novel deep network that we trained on an augmented dataset and evaluated with real data. The network contains an embedded human body mesh model and uses a white-box model of depth and pressure image generation. Our network successfully infers body pose, outperforming prior work. It also infers contact pressure across a 3D mesh model of the human body, which is a novel capability, and does so in the presence of occlusion from blankets.
We develop and evaluate a respiratory rate estimation algorithm that utilizes data from pressure-sensitive mat (PSM) technology for continuous patient monitoring in neonatal intensive care units (NICU). An analysis of the random effect of drift and systematic effect of creep in the PSM data is presented, showing that these are essentially dependent on the applied load and contact surface. Uncertainty measurements are pivotal when estimating physiologic parameters. The standard uncertainty in the PSM data is here represented by the percent drift. Next, we evaluate the applicability of PSM technology to estimate RR in neonatal patient simulator trials under five mixed effects including internally and externally induced motion, mattress type, grunting, laying position, and different breathing rates. We analyze the limits of agreement on the mixed effects model to derive the uncertainty in the estimated RR obtained through two estimation techniques. In comparison with the gold standard RR values, we achieved a mean bias of 0.56 breaths per minute (bpm) with an error bounded by a 95% confidence interval of [-2.26, 3.37] bpm. These results meet the clinical accuracy requirements of RR wi
Smart devices in the Internet of Things (IoT) paradigm provide a variety of unobtrusive and pervasive means for continuous monitoring of bio-metrics and health information. Furthermore, automated personalization and authentication through such smart systems can enable better user experience and security. In this paper, simultaneous estimation and monitoring of body mass index (BMI) and user identity recognition through a unified machine learning framework using smart beds is explored. To this end, we utilize pressure data collected from textile-based sensor arrays integrated onto a mattress to estimate the BMI values of subjects and classify their identities in different positions by using a deep multitask neural network. First, we filter and extract 14 features from the data and subsequently employ deep neural networks for BMI estimation and subject identification on two different public datasets. Finally, we demonstrate that our proposed solution outperforms prior works and several machine learning benchmarks by a considerable margin, while also estimating users' BMI in a 10-fold cross-validation scheme.
This paper presents a robust method to monitor heart rate (HR) from BCG (Ballistocardiography) signal, which is acquired from the sensor embedded in a chair or a mattress. The proposed algorithm addresses the shortfalls in traditional Fast Fourier Transform (FFT) based approaches by introducing Hilbert Transform to extract the pulse envelope that models the repetition of J-peaks in BCG signal. The frequency resolution is further enhanced by applying FFT and phase vocoder to the pulse envelope. The performance of the proposed algorithm is verified by experiment from 7 subjects. For HR estimation, mean absolute error (MAE) of 0.90 beats per minute (BPM) and standard deviation of absolute error (STD) of 1.14 BPM are obtained. Pearson correlation coefficient between estimated HR and ground truth HR of 0.98 is also achieved.