The kinematics analysis of foot-ankle complex during gait is essential for advancing biomechanical research and clinical assessment. Collecting accurate surface geometry data from the foot and ankle during dynamic gait conditions is inherently challenging due to swing foot occlusions and viewing limitations. Thus, this paper introduces FootGait3D, a novel multi-view dataset of high-resolution ankle-foot surface point clouds captured during natural gait. Different from existing gait datasets that typically target whole-body or lower-limb motion, FootGait3D focuses specifically on the detailed modeling of the ankle-foot region, offering a finer granularity of motion data. To address this, FootGait3D consists of 8,403 point cloud frames collected from 46 subjects using a custom five-camera depth sensing system. Each frame includes a complete 5-view reconstruction of the foot and ankle (serving as ground truth) along with partial point clouds obtained from only four, three, or two views. This structured variation enables rigorous evaluation of 3D point cloud completion methods under varying occlusion levels and viewpoints. Our dataset is designed for shape completion tasks, facilitatin
State-of-the-art methods can recover accurate overall 3D human body motion from in-the-wild videos. However, they often fail to capture fine-grained articulations, especially in the feet, which are critical for applications such as gait analysis and animation. This limitation results from training datasets with inaccurate foot annotations and limited foot motion diversity. We address this gap with FootMR, a Foot Motion Refinement method that refines foot motion estimated by an existing human recovery model through lifting 2D foot keypoint sequences to 3D. By avoiding direct image input, FootMR circumvents inaccurate image-3D annotation pairs and can instead leverage large-scale motion capture data. To resolve ambiguities of 2D-to-3D lifting, FootMR incorporates knee and foot motion as context and predicts only residual foot motion. Generalization to extreme foot poses is further improved by representing joints in global rather than parent-relative rotations and applying extensive data augmentation. To support evaluation of foot motion reconstruction, we introduce MOOF, a 2D dataset of complex foot movements. Experiments on MOOF, MOYO, and RICH show that FootMR outperforms state-of-
The present study focused on the effects of trunk extensor muscles fatigue on postural control during quiet standing under different somatosensory conditions from the foot and the ankle. With this aim, 20 young healthy adults were asked to stand as immobile as possible in two conditions of No fatigue and Fatigue of trunk extensor muscles. In Experiment 1 (n = 10), somatosensation from the foot and the ankle was degraded by standing on a foam surface. In Experiment 2 (n = 10), somatosensation from the foot and ankle was facilitated through the increased cutaneous feedback at the foot and ankle provided by strips of athletic tape applied across both ankle joints. The centre of foot pressure displacements (CoP) were recorded using a force platform. The results showed that (1) trunk extensor muscles fatigue increased CoP displacements under normal somatosensatory conditions (Experiment 1 and Experiment 2), (2) this destabilizing effect was exacerbated when somatosensation from the foot and the ankle was degraded (Experiment 1), and (3) this destabilizing effect was mitigated when somatosensation from the foot and the ankle was facilitated (Experiment 2). Altogether, the present finding
Walking on compliant terrain presents a substantial challenge for individuals with lower-limb amputation, further elevating their already high risk of falling. While powered ankle-foot prostheses have demonstrated adaptability across speeds and rigid terrains, control strategies optimized for soft or compliant surfaces remain underexplored. This work experimentally validates an admittance-based control strategy that dynamically adjusts the quasi-stiffness of powered prostheses to enhance gait stability on compliant ground. Human subject experiments were conducted with three healthy individuals walking on two bilaterally compliant surfaces with ground stiffness values of 63 and 25 kN/m, representative of real-world soft environments. Controller performance was quantified using phase portraits and two walking stability metrics, offering a direct assessment of fall risk. Compared to a standard phase-variable controller developed for rigid terrain, the proposed admittance controller consistently improved gait stability across all compliant conditions. These results demonstrate the potential of adaptive, stability-aware prosthesis control to reduce fall risk in real-world environments a
This paper extends the forced-oscillation-based reduced-order model of walking to a model with ankles and feet. A human-inspired paradigm was designed for the ankle dynamics, which results in improved gait characteristics compared to the point-foot model. In addition, it was shown that while the proposed model can stabilize against large errors in initial conditions through combination of foot placement and ankle strategies, the model is able to stabilize against small perturbations without relying on the foot placement control and solely through the designed proprioceptive ankle scheme. This novel property, which is also observed in humans, can help in better understanding of anthropomorphic walking and its stabilization mechanisms.
Simulation of assistive devices on pathological gait through musculoskeletal models offers the potential and advantages of estimating the effect of the device in several biomechanical variables and the device characteristics ahead of manufacturing. In this study, we introduce a novel musculoskeletal modelling approach to simulate the biomechanical impact of ankle foot orthoses (AFO) on gait in individuals with spinal cord injury (SCI). Leveraging data from the Swiss Paraplegic Center, we constructed anatomically and muscularly scaled models for SCI-AFO users, aiming to predict changes in gait kinematics and kinetics. The importance of this work lies in its potential to enhance rehabilitation strategies and improve quality of life by enabling the pre-manufacturing assessment of assistive devices. Despite the application of musculoskeletal models in simulating walking aids effects in other conditions, no predictive model currently exists for SCI gait. Evaluation through RMSE showed similar results compared with other pathologies, simulation errors ranged between 0.23 to 2.3 degrees in kinematics. Moreover, the model was able to capture ankle joint muscular asymmetries and predict sym
Cadaveric studies have provided important insights into the mechanics of the human foot arch and plantar fascia. However, repeatedly probing posture-dependent viscoelastic responses immediately after landing impact is difficult in biological specimens, leaving the contribution of skeletal architecture to landing dynamics incompletely understood. In this study, we developed an anthropomimetic foot joint structure aimed at replicating the skeletal geometry of the human foot. Using a vertical drop apparatus that simulates landing and a viscoelastic system-identification model, we investigated how skeletal structure and posture modulate the apparent post-impact viscoelastic response. The results show that the multi-jointed anthropomimetic structure exhibited a higher damping ratio than simplified flat and rigid feet. Moreover, ankle dorsiflexion and toe extension systematically shifted the identified parameters, reducing the damping ratio under the tested conditions. Taken together, these findings indicate that an arch-like, multi-jointed skeletal architecture can enhance impact attenuation in an anthropomimetic mechanical foot, and that morphology and passive posture alone can tune th
Recent technological advancements in artificial intelligence and computer vision have enabled gait analysis on portable devices such as cell phones. However, most state-of-the-art vision-based systems still impose numerous constraints for capturing a patient's video, such as using a static camera and maintaining a specific distance from it. While these constraints are manageable under professional observation, they pose challenges in home settings. Another issue with most vision-based systems is their output, typically a classification label and confidence value, whose reliability is often questioned by medical professionals. This paper addresses these challenges by presenting a novel system for gait analysis robust to camera movements and providing explanations for its output. The study utilizes a dataset comprising videos of subjects wearing two types of Knee Ankle Foot Orthosis (KAFO), namely "Locked Knee" and "Semi-flexion," for mobility, along with metadata and ground truth for explanations. The ground truth highlights the statistical significance of seven features captured using motion capture systems to differentiate between the two gaits. To address camera movement challeng
Unilateral muscle weakness often leads to asymmetric gait, disrupting interlimb coordination and stance timing. This study presents a reinforcement learning (RL) based musculoskeletal simulation framework to (1) quantify how progressive unilateral muscle weakness affects gait symmetry and (2) evaluate whether ankle exoskeleton assistance can improve gait symmetry under impaired conditions. The overarching goal is to establish a simulation- and learning-based workflow that supports early controller development prior to patient experiments. Asymmetric gait was induced by reducing right-leg muscle strength to 75%, 50%, and 25% of baseline. Gait asymmetry was quantified using toe-off timing, peak contact forces, and joint-level symmetry metrics. Increasing weakness produced progressively larger temporal and kinematic asymmetry, most pronounced at the ankle. Ankle range of motion symmetry degraded from near-symmetric behavior at 100% strength (symmetry index, SI = +6.4%; correlation r=0.974) to severe asymmetry at 25% strength (SI = -47.1%, r=0.889), accompanied by a load shift toward the unimpaired limb. At 50% strength, ankle exoskeleton assistance improved kinematic symmetry relative
Ankle proprioceptive deficits are common after stroke and occur independently of ankle motor impairments. Despite this independence, some studies have found that ankle proprioceptive deficits predict gait function, consistent with the concept that somatosensory input plays a key role in gait control. Other studies, however, have not found a relationship, possibly because of variability in proprioception assessments. Robotic assessments of proprioception offer improved consistency and sensitivity. Here we relationships between ankle proprioception, ankle motor impairment, and gait function after stroke using robotic assessments of ankle proprioception. We quantified ankle proprioception using two different robotic tests (Joint Position Reproduction and Crisscross) in 39 persons in the chronic phase of stroke. We analyzed the extent to which these robotic proprioception measures predicted gait speed, measured over a long distance (6-minute walk test) and a short distance (10-meter walk test). We also studied the relationship between robotic proprioception measures and lower extremity motor impairment, quantified with measures of ankle strength, active range of motion, and the lower e
Passive dynamic walkers are widely adopted as a mathematical model to represent biped walking. The stable locomotion of these models is limited to tilted surfaces, requiring gravitational energy. Various techniques, such as actuation through the ankle and hip joints, have been proposed to extend the applicability of these models to level ground and rough terrain with improved locomotion efficiency. However, most of these techniques rely on impulsive energy injection schemes and torsional springs, which are quite challenging to implement in a physical platform. Here, a new model is proposed, named triggering controlled ankle actuated compass gait (TC-AACG), which allows non-instantaneous compliant ankle pushoff. The proposed technique can be implemented in physical platforms via series elastic actuators (SEAs). Our systematic examination shows that the proposed approach extends the locomotion capabilities of a biped model compared to impulsive ankle pushoff approach. We provide extensive simulation analysis investigating the locomotion speed, mechanical cost of transport, and basin of attraction of the proposed model.
Powered ankle-foot prostheses can often reduce the energy cost of walking by assisting with push-off. However, focus on providing mechanical work may lead to ignoring or exacerbating common issues with chronic pain, irritation, pressure ulcer development, and eventual osteoarthritis in persons with amputation. This paper presents the design and validation of a novel transtibial prosthesis informed by predictive biomechanical simulations of gait which minimize a combination of user effort and interaction loading from the prosthesis socket. From these findings, the device was designed with a non-biomimetic anterior-posterior translation degree of freedom with a 10 cm range of motion which is primarily position-controlled to change the alignment of the prosthetic foot with the residual limb. The system is both mobile and tethered, with the batteries, actuators, and majority of electronics located in a small backpack. Mechanical loads are transmitted through cables to the prosthesis, minimizing the distal mass carriage required. We measured torque and force sensing accuracy, open loop actuator performance, closed loop torque and position control bandwidth, and torque and position track
It is technically challenging to design efficient transceiver coil arrays for foot and ankle imaging at ultrahigh fields due to the irregular geometry of the anatomy. Shortened wavelength because of the high operation frequency at ultrahigh fields increases phase variation, leading to inhomogeneous B1 distribution in the imaging sample. In this work, we propose a hybrid design with mixed L-C loops and microstrip resonators for multichannel foot/ankle transceiver arrays at the ultrahigh field of 7T. The proposed transceiver array consists of 14 microstrip resonators and 5 L-C loop coils to cover the entire region of interest of the irregular-shaped foot/ankle with a relatively uniform B1 distribution at 7T. The feasibility and field behavior of the proposed design are systematically investigated numerically.
Assistive ankle-foot orthoses (AAFOs) are powerful solutions to assist or rehabilitate gait on humans. Existing AAFO technologies include passive, quasi-passive, and active principles to provide assistance to the users, and their mechanical configuration and control depend on the eventual support they aim for within the gait pattern. In this research we analyze the state-of-the-art of AAFO and classify the different approaches into clusters, describing their basis and working principles. Additionally, we reviewed the purpose and experimental validation of the devices, providing the reader with a better view of the technology readiness level. Finally, the reviewed designs, limitations, and future steps in the field are summarized and discussed.
Humans rely on ankle torque to maintain standing balance, particularly in the presence of small to moderate perturbations. Reductions in maximum torque (MT) production and maximum rate of torque development (MRTD) occur at the ankle with age, diminishing stability. Ankle exoskeletons are powered orthotic devices that may assist older adults by compensating for reduced muscle force and power production capabilities. They may also be able to assist with ankle strategies used for balance. However, no studies have investigated the effect of such devices on balance in older adults. Here, we model the effect ankle exoskeletons have on stability in physics-based models of healthy young and old adults, focusing on the mitigation of age-related deficits such as reduced MT and MRTD. We show that an ankle exoskeleton moderately reduces feasible stability boundaries in users who have full ankle strength. For individuals with age-related deficits, there is a trade-off. While exoskeletons augment stability in low velocity conditions, they reduce stability in some high velocity conditions. Our results suggest that well-established control strategies must still be experimentally validated in older
Stationary robotic trainers are lower limb rehab robots which often incorporate an exoskeleton attached to a stationary base. The issue observed in the stationery trainers for simultaneous knee and ankle-foot complex joints is that they restrict the natural motion of ankle-foot in the rehab trainings due to the insufficient Degrees of Freedom (DOFs) of these trainers. A new stationary knee-ankle-foot rehab robot with all necessary DOFs is developed here. A typical rehab training is first implemented in simulation, and then tested on a healthy subject. Results show that the proposed system functions naturally and meets the requirements of the desired rehab training.
This paper proposes a novel contact and wearable sensing system for estimating the upper body posture and joint angles (ankle, knee, and hip) of the human body using foot pressure distribution information obtained from a sensor attached to the plantar region. In the proposed estimation method, sensors are installed only on the plantar region, which is the end of the human body and the point of contact with the environment. The posture and joint angles of other parts of the body are estimated using only this information. As a contact and wearable sensor, the proposed system differs from previous measurement systems in the sense that the sensor does not need to be placed near the target joint or body. The estimation was carried out using a multivariate linear regression model with the foot pressure distribution as the input and the joint angle or posture as the output. The results reveal that it is possible to estimate the posture and joint angles of the human body from foot pressure distribution information (R2$\fallingdotseq$0.9). The proposed estimation method was validated by morphological computation to confirm that it is enabled by foot morphology. The validation approach compa
Defant and Kravitz considered the following problem: Suppose that, to the right of a foot, there is a line of colored socks that needs to be sorted. However, at any point in time, one can only either place the leftmost sock to the right of the foot onto the foot (stack) or remove the outermost sock on the foot and make it the rightmost sock to the left of the foot (unstack). In this paper, we explicitly describe all minimal initial sock orderings that are unsortable.
The design of the humanoid ankle is critical for safe and efficient ground interaction. Key factors such as mechanical compliance and motor mass distribution have driven the adoption of parallel mechanism architectures. However, selecting the optimal configuration depends on both actuator availability and task requirements. We propose a unified methodology for the design and evaluation of parallel ankle mechanisms. A multi-objective optimization synthesizes the mechanism geometry, the resulting solutions are evaluated using a scalar cost function that aggregates key performance metrics for cross-architecture comparison. We focus on two representative architectures: the Spherical-Prismatic-Universal (SPU) and the Revolute-Spherical-Universal (RSU). For both, we resolve the kinematics, and for the RSU, introduce a parameterization that ensures workspace feasibility and accelerates optimization. We validate our approach by redesigning the ankle of an existing humanoid robot. The optimized RSU consistently outperforms both the original serial design and a conventionally engineered RSU, reducing the cost function by up to 41% and 14%, respectively.
Because of the complicated mechanism of ankle injury, it is very difficult to diagnose ankle fracture in clinic. In order to simplify the process of fracture diagnosis, an automatic diagnosis model of ankle fracture was proposed. Firstly, a tibia-fibula segmentation network is proposed for the joint tibiofibular region of the ankle joint, and the corresponding segmentation dataset is established on the basis of fracture data. Secondly, the image registration method is used to register the bone segmentation mask with the normal bone mask. Finally, a semi-supervised classifier is constructed to make full use of a large number of unlabeled data to classify ankle fractures. Experiments show that the proposed method can segment fractures with fracture lines accurately and has better performance than the general method. At the same time, this method is superior to classification network in several indexes.