The process of collecting blood from donors and making it available for transfusion requires a complex series of operations involving multiple actors and resources at each step. Ensuring hospitals receive adequate and safe blood for transfusion is a common challenge across low- and middle-income countries, but is rarely addressed from a system level. This paper presents the first use of discrete event simulation to study the blood system in Kenya and to explore the effect of variations and perturbations at different steps of the system on meeting patient blood demand. A process map of the Kenyan blood system was developed to capture critical steps from blood donation to transfusion using interviews with blood bank, hospital, and laboratory personnel at four public hospitals across three counties in Kenya. The blood system was simulated starting with blood collection, a blood bank where blood is tested and stored before it is issued, a major hospital attached to the blood bank, and several smaller hospitals served by the same blood bank. Values for supply-side parameters were based mainly on expert opinion; demand-side parameters were based on data from blood requisitions made in ho
Blood Donation and Blood Transfusion Services (BTS) are crucial for saving people lives. Recently, worldwide efforts have been undertaken to utilize social media and smartphone applications to make the blood donation process more convenient, offer additional services, and create communities around blood donation centers. Blood banks suffer frequent shortage of blood; hence, advertisements are frequently seen on social networks urging healthy individuals to donate blood for patients who urgently require blood transfusion. The blood donation process usually consumes a lot of time and effort from both donors and medical staff since there is no concrete information system that allows donors and blood donation centers communicate efficiently and coordinate with each other to minimize time and effort required for blood donation process. Moreover, most blood banks work in isolation and are not integrated with other blood donation centers and health organizations which affect the blood donation and blood transfusion services quality. This work aims at developing a Blood Donation System (BDS) based on the cutting-edge information technologies of cloud computing and mobile computing.
The influence of blood rheology on hemodynamic parameters is investigated using Computational Fluid Dynamics on blood flow through the human carotid artery. We performed three-dimensional modeling and simulation to study blood flow through the carotid artery, which is divided into internal and exterior parts with a decreased radius. The blood flow was classified as basic pulsatile to simulate the human heart's rhythmic pulses. For hemodynamic modeling viscosity of the fluid, the Carreau model was utilized with four distinct blood instances: Anemic, diabetic, and two healthy blood types. The boundary conditions with Carreau viscosity were applied using the Ansys Fluent simulator, and the governing equations were solved using the finite volume technique. Different time steps were tested for their impact on wall deformation, strain rate, blood velocity, pressure, wall shear, and skin friction coefficient. The hemodynamical parameters were calculated using many cross-sectional planes along the artery. Finally, the impact of the four types of blood cases listed above was investigated, and we discovered that each blood case has a substantial impact on blood velocity, pressure, wall shear
Blood donation is a critical component of healthcare, yet locating suitable donors in emergencies often presents significant challenges. This paper presents the design and development of a Blood Donation Web Platform, a web-based system that connects patients, donors, and administrators within a centralized digital space. The platform allows interested donors to register their personal information, including blood group, contact details, and availability. Patients can search for donors based on blood group and location, and the system provides a list of nearby donors who are ready to donate. The platform design was guided by use case, database, class, and sequence diagrams to ensure a well-structured and efficient system architecture. Modern web technologies, including PHP (Laravel framework), HTML, CSS, Bootstrap, and MySQL, supported by XAMPP and Visual Studio Code, were employed to implement a dynamic, interactive, and user-friendly platform. By streamlining donor refgistration, blood requests, and communication, the proposed system reduces delays and complexities in emergencies, improving timely accessibility of blood and enhancing overall efficiency in blood donation services.
Our research addresses the critical challenge of managing blood transfusions and optimizing allocation in resource-constrained regions. We present heuristic matching algorithms for donor-patient and blood bank selection, alongside machine learning methods to analyze blood transfusion acceptance data and predict potential shortages. We developed simulations to optimize blood bank operations, progressing from random allocation to a system incorporating proximity-based selection, blood type compatibility, expiration prioritization, and rarity scores. Moving from blind matching to a heuristic-based approach yielded a 28.6% marginal improvement in blood request acceptance, while a multi-level heuristic matching resulted in a 47.6% improvement. For shortage prediction, we compared Long Short-Term Memory (LSTM) networks, Linear Regression, and AutoRegressive Integrated Moving Average (ARIMA) models, trained on 170 days of historical data. Linear Regression slightly outperformed others with a 1.40% average absolute percentage difference in predictions. Our solution leverages a Cassandra NoSQL database, integrating heuristic optimization and shortage prediction to proactively manage blood r
Accurate classification of blood cells plays a key role in improving automated blood analysis for both medical and veterinary applications. This work presents a two-stage deep clustering method for classifying blood cells from high-dimensional signal data. In the first stage, red blood cells (RBCs) and platelets (PLTs) are separated using a combination of an improved autoencoder and the IDEC algorithm. The second stage further classifies RBC subtypes, pure RBCs, reticulocytes, and clumped RBCs, through a variational deep embedding (VaDE) approach. Due to the lack of detailed cell-level labels, soft classification probabilities are generated from sample-level data to approximate the true distributions. The aim is to contribute to the development of low-cost, automated blood analysis systems suitable for veterinary and biomedical use. Initial results indicate this method shows promise in effectively distinguishing different blood cell populations, even with limited supervision.
Identification of a person is central in forensic science, security, and healthcare. Methods such as iris scanning and genomic profiling are more accurate but expensive, time-consuming, and more difficult to implement. This study focuses on the relationship between the fingerprint patterns and the ABO blood group as a biometric identification tool. A total of 200 subjects were included in the study, and fingerprint types (loops, whorls, and arches) and blood groups were compared. Associations were evaluated with statistical tests, including chi-square and Pearson correlation. The study found that the loops were the most common fingerprint pattern and the O+ blood group was the most prevalent. Even though there was some associative pattern, there was no statistically significant difference in the fingerprint patterns of different blood groups. Overall, the results indicate that blood group data do not significantly improve personal identification when used in conjunction with fingerprinting. Although the study shows weak correlation, it may emphasize the efforts of multi-modal based biometric systems in enhancing the current biometric systems. Future studies may focus on larger and
Blood, a ubiquitous and fundamental carbohydrate material composed of plasma, red blood cells, white blood cells, and platelets, has been playing an important role in biology, life science, history, and religious study, while graphene has garnered significant attention due to its exceptional properties and extensive range of potential applications. Achieving environmentally friendly, cost-effective growth using hybrid precursors and obtaining high-quality graphene through a straightforward CVD process has been traditionally considered mutually exclusive. This study demonstrates that we can produce high-quality graphene domains with controlled thickness through a one-step growth process at atmospheric pressure using blood as a precursor. Raman spectroscopy confirms the uniformity of the blood-grown graphene films, and observing the half-integer quantum Hall effect in the measured devices highlights its outstanding electronic properties. This unprecedented approach opens possibilities for blood application, facilitating an unconventional route in graphene growth applications.
Machine learning has endless applications in the health care industry. White blood cell classification is one of the interesting and promising area of research. The classification of the white blood cells plays an important part in the medical diagnosis. In practise white blood cell classification is performed by the haematologist by taking a small smear of blood and careful examination under the microscope. The current procedures to identify the white blood cell subtype is more time taking and error-prone. The computer aided detection and diagnosis of the white blood cells tend to avoid the human error and reduce the time taken to classify the white blood cells. In the recent years several deep learning approaches have been developed in the context of classification of the white blood cells that are able to identify but are unable to localize the positions of white blood cells in the blood cell image. Following this, the present research proposes to utilize YOLOv3 object detection technique to localize and classify the white blood cells with bounding boxes. With exhaustive experimental analysis, the proposed work is found to detect the white blood cell with 99.2% accuracy and clas
Despite decades of research on blood flow, an analogue of Navier-Stokes equations that accurately describe blood flow properties has not been established yet. The reason behind this is that the properties of blood flow seem à priori non universal as they depend on various factors such as global concentration of red blood cells (RBCs) and channel width. Here, we have discovered a universal law when the stress and strain rate are measured at a given local RBCs concentration. However, the local concentration must be determined in order to close the problem. We propose a non-local diffusion equation of RBCs concentration that agrees with the full simulation. The universal law is exemplified for both shear and pressure driven flows. While the theory is restricted to a simplistic geometry (straight channel) it provides a fundamental basis for future research on blood flow dynamics and could lead to the development of a new theory that accurately describes blood flow properties under various conditions, such as in complex vascular networks.
Dynamic and precise measurement of cerebral blood flow velocity is crucial in neuroscience and the diagnosis of cerebrovascular diseases. Traditional color Doppler ultrasound can only measure the velocity component along the ultrasound beam, which restricts its ability to accurately capture the complete blood flow vector in complex environments. To overcome these limitations, we propose an ultrafast pulse-coded vector Doppler (PC-UVD) imaging method, utilizing Hadamard matrix-based pulse encoding to improve velocity estimation accuracy under low signal-to-noise ratio (SNR) conditions. Our study encompasses spiral flow simulations and in vivo rat brain experiments, showing significantly enhanced measurement precision compared to conventional ultrafast vector Doppler (UVD). This innovative approach enables the measurement of dynamic cerebral blood flow velocity within a single cardiac cycle, offering insights into the characteristics of cerebrovascular resistivity. The proposed PC-UVD method employs Hadamard matrix encoding of plane waves, boosting SNR without compromising temporal or spatial resolution. Velocity vectors are subsequently estimated using a weighted least squares (WLS)
Leukemia is diagnosed with complete blood counts which is by calculating all blood cells and compare the number of white blood cells (White Blood Cells / WBC) and red blood cells (Red Blood Cells / RBC). Information obtained from a complete blood count, has become a cornerstone in the hematology laboratory for diagnostic purposes and monitoring of hematological disorders. However, the traditional procedure for counting blood cells manually requires effort and a long time, therefore this method is one of the most expensive routine tests in laboratory hematology clinic. Solution for such kind of time consuming task and necessity of data tracability can be found in image processing techniques based on blood cell morphology . This study aims to identify Acute Lymphocytic Leukemia (ALL) and Acute Myeloid Leukemia type M3 (AML M3) using Fuzzy Rule Based System based on morphology of white blood cells. Characteristic parameters witch extractedare WBC Area, Nucleus and Granule Ratio of white blood cells. Image processing algorithms such as thresholding, Canny edge detection and color identification filters are used.Then for identification of ALL, AML M3 and Healthy cells used Fuzzy Rule Ba
The flow dynamics of red blood cells in vivo in blood capillaries and in vitro in microfluidic channels is complex. Cells can obtain differnet shapes such as discoid, parachute, slipper-like shapes and various intermediate states depending on flow conditions and their viscoelastic properties. We use artificial intelligence based analysis of red blood cells (RBCs) in an oscillating mircorchannel to distinguish healthy red blood cells from red blood cells treated with formaldehyde to chemically modify their viscoelastic behavior. We used TensorFlow to train and validate a deep learning model and achived a testing accuracy of over 90%. This method is a first step to a non-invasive, label-free characterization of diseased red blood cells and will be useful for diagnostic purposes in haematology labs. This method provides quantitative data on the number of affected cells based on single cell classification.
A complete thermodynamical analysis for a blood model, based on mixture theory, is performed. The model is developed considering the blood as a suspension of red blood cells (solid component) in the plasma (fluid component), and taking into account the temperature effects. Furthermore, two independent scalar internal variables are introduced accounting for additional dissipative effects. Using Clausius-Duhem inequality, the general thermodynamic restrictions and residual dissipation inequality are derived. The thermodynamic admissibility with the second law of thermodynamics is assessed by means of the extended Coleman-Noll procedure; in one space dimension we exhibit a solution of all the thermodynamical constraints.
Previous studies suggest that the behaviour of impacting blood is similar to that of a Newtonian fluid, which has a shear viscosity equivalent to that of blood at high shear rates. To understand this important fact, we conducted comparative experiments of droplet impact on a glass surface using whole blood and three solutions with a shear viscosity similar to that of blood. Specifically, we used dog's whole blood (deformable red blood cells dispersed in plasma, WB), plasma with non-deformable resin particles (PwP), glycerol and water with resin particles (GWwP), and a commercial blood simulant (hard particles dispersed in a water-based Newtonian solution, BS). The ranges of Reynolds and Weber numbers in our experiments were 550 $<Re<$ 1700 and 120 $<We<$ 860, respectively. Side and bottom views of droplet impact were simultaneously recorded by two high-speed cameras. The spreading radius of the impacting WB droplet in our experiments agreed well with that of Newtonian fluids with viscosity similar to that of WB at high shear rates. Splashing droplets of WB and Newtonian fluids form finger structures (finger-splashing). Although PwP has a viscosity similar to that of WB
Our purpose is to measure the internal radiation dose (ID) using human blood sample. In the literature, there is no process that allows the direct measurement of ID received by a person. This study has shown that it is possible to determine ID in human blood exposed to internal or external ionizing radiation treatment both directly and retrospectively. OSL technique was used to measure the total dose from the blood sample. OSL counts from the waste blood of the patient injected with a radiopharmaceutical for diagnostic or treatment purposes and from a blood sample having a laboratory-injected radiation dose were both used for measurements. The decay and dose-response curves (DRC) were plotted for different doses. The doses received by different blood aliquots have been determined by interpolating the natural luminescence counts to DRC. In addition, OSL counts from a healthy blood sample exposed to an external radiation source were measured. The blood aliquots were given different 0-200Gy beta doses and their decay and dose-response curves were plotted. The internal dose received by the blood aliquots injected with radioisotope was determined by interpolating the natural luminescenc
We present a method and model for the direct and continuous separation of red and white blood cells in plasma. The method is implemented at the microscale using a microfluidic system that consists of an array of integrated soft-magnetic elements embedded beneath a microfluidic channel. The microsystem is passive, and is activated via application of a bias field that magnetizes the elements. Once magnetized, the elements produce a nonuniform magnetic field distribution in the microchannel, which gives rise to a force on blood cells as they pass through the microsystem. In whole blood, white blood cells behave as diamagnetic microparticles while red blood cells exhibit diamagnetic or paramagnetic behavior depending on the oxygenation of their hemoglobin. We develop a mathematical model for predicting the motion of blood cells in the microsystem that takes into account the dominant magnetic, fluidic and buoyant forces on the cells. We use the model to study red/white blood cell transport, and our analysis indicates that the microsystem is capable of rapid and efficient red/white blood cell separation.
Non-invasive measurement of the arterial blood speed gives rise to important healthinformation such as cardio output and blood supplies to vital organs. The magnitude andchange in arterial blood speed are key indicators of the health conditions and development andprogression of diseases. We demonstrated a simple technique to directly measure the blood flowspeed in main arteries based on the diffused light model. The concept is demonstrated with aphantom that uses intralipid hydrogel to model the biological tissue and an embedded glass tubewith flowing human blood to model the blood vessel. The correlation function of the measuredphotocurrent was used to find the electrical field correlation function via the Siegert relation.We have shown that the characteristic decorrelation rate (i.e. the inverse of the decoherent time)is linearly proportional to the blood speed and independent of the tube diameter. This strikingproperty can be explained by an approximate analytic solution for the diffused light equation inthe regime where the convective flow is the dominating factor for decorrelation. As a result, wehave demonstrated a non-invasive method of measuring arterial blood speed without
The liver has a unique blood supply system and plays an important role in the human blood circulatory system. Thus, hemodynamic problems related to the liver serve as an important part in clinical diagnosis and treatment. Although estimating parameters in these hemodynamic models is essential to the study of liver models, due to the limitations of medical measurement methods and constraints of ethics on clinical studies, it is impossible to directly measure the parameters of blood vessels in livers. Furthermore, as an important part of the systemic blood circulation, livers' studies are supposed to be in conjunction with other blood vessels. In this article, we present an innovative method to fix parameters of an individual liver in a human blood circulation using non-invasive clinical measurements. The method consists of a 1-D blood flow model of human arteries and veins, a 0-D model reflecting the peripheral resistance of capillaries and a lumped parameter circuit model for human livers. We apply the finite element method in fluid mechanics of these models to a numerical study, based on non-invasive blood related measures of 33 individuals. The estimated results of human blood ve
In this paper, we present a mathematical and numerical model for blood solidification and its rupture in stenosed arteries. The interaction between the blood flow and an existing stenosis in the arterial wall is modeled as a three dimensional fluid-structure interaction problem. The blood is assumed to be a non-Newtonian incompressible fluid with a time-dependent viscosity that obeys a modified Carreau's model and the flow dynamics is described by the Navier-Stokes equations. Whereas, the arterial wall is considered a hyperelastic material whose displacement satisfies the quasi-static equilibrium equations. Numerical simulations are performed using FreeFem++ on a two dimensional domain. We investigate the behavior of the viscosity of blood, its speed and the maximum shear stress. From the numerical results, blood recirculation zones have been identified. Moreover, a zone of the blood of high viscosity and low speed has been observed directly after the stenosis in the flow direction. This zone may correspond to a blood accumulation and then solidification zone that is subjected to shear stress by the blood flow and to forces exerted by the artery wall deformation. Therefore, this zo