Suspension microarrays based on optically encoded microbeads have become one of the most versatile platforms for multiplexed bioanalysis because they combine solution-phase reaction kinetics, flexible assay design, and high-throughput detection. However, despite more than two decades of intense research, no consensus has emerged regarding the optimal strategies for particle encoding, surface functionalization, and signal decoding. Progress has mainly been driven by incremental improvements in individual materials rather than by systematic comparison of competing technological concepts. This review critically evaluates the main approaches to the fabrication of optically encoded microbeads, including post-synthetic (swelling and layer-by-layer assembly) and in situ encoding strategies, and proposes a mechanistic classification of in situ methods of particle formation into polymerization-driven and confinement-controlled ones. Instead of comparing the fabrication methods solely in terms of encoding capacity, we assess their relative merits in terms of structural control, code stability, scalability, compatibility with biofunctionalization, and suitability for clinical implementation.
Multidimensional or multiplex bioanalysis represents a crucial approach to improve diagnostic precision, increase assay throughput and advance fundamental discoveries in analytical industry, life science and nanomedicine. Along this line, bio-interfacing magnetic particles have been playing an important role. Fully exploiting the properties of magnetic particles is the key to tailoring recent technology development for better translational outcomes. In this mini-review, typical magnetophysical dimensions of magnetic particles are introduced. Recent progress of implementing these dimensions with advanced sensor and actuator technologies in multiplex bioanalysis is discussed. Outlooks on potential biomedical applications and challenges are provided.
Whispering gallery mode (WGM) laser sensors, utilizing the interaction between the in-plane evanescent field and the surface vicinity, provide enhanced sensitivity in label-free sensing for bioanalysis and disease screening. However, the unavoidably excited spiral modes resulting from the weak axial confinement and their sensing potential were overlooked. In this study, a microfluidic biosensor using the localized conical modes of an active resonator based on the thin-walled capillaries was developed, demonstrating ultrasensitive refractive index and biomolecule detection capabilities. This sensor provides nonspecific detection of bovine serum albumin (BSA) and specific detection of Carcinoembryonic antigen-related cell adhesion molecule 5 (CEACAM5) with ultra-low detection limits, large sensing range, rapid response, and a cost-effective design, making it a promising candidate for industrial-scale production. The theoretical detection limit for CEACAM5 is as low as 0.38ag/mL (5zM), and the sensitivity in the linear region reaches 0.25nm/(ag/mL). These results are approximately an order of magnitude higher in sensitivity than currently reported active WGM biosensors, demonstrating
Microfluidic droplet screens serve as an innovative platform for high-throughput biotechnology, enabling significant advancements in discovery, product optimization, and analysis. This review sheds light on the emerging trend of interaction assays in microfluidic droplets, underscoring the unique suitability of droplets for these applications. Encompassing a diverse range of biological entities such as antibodies, enzymes, DNA, RNA, various microbial and mammalian cell types, drugs, and other molecules, these assays demonstrate their versatility and scope. Recent methodological breakthroughs have escalated these screens to novel scales of bioanalysis and biotechnological product design. Moreover, we highlight pioneering advancements that extend droplet-based screens into new domains: cargo delivery within human bodies, application of synthetic gene circuits in natural environments, 3D-printing, and the development of droplet structures responsive to environmental signals. The potential of this field is profound and only set to increase.
When a micron-sized magnetizable particle is introduced into a suspension of nanosized magnetic particles, the nanoparticles accumulate around the microparticle and form thick anisotropic clouds extended in the direction of the applied magnetic field. This phenomenon promotes colloidal stabilization of bimodal magnetic suspensions and allows efficient magnetic separation of nanoparticles used in bioanalysis and water purification. In the present work, size and shape of nanoparticle clouds under the simultaneous action of an external uniform magnetic field and the flow have been studied in details. In experiments, dilute suspension of iron oxide nanoclusters (of a mean diameter of 60 nm) was pushed through a thin slit channel with the nickel microspheres (of a mean diameter of 50$μ$m) attached to the channel wall. The behavior of nanocluster clouds was observed in the steady state using an optical microscope. In the presence of strong enough flow, the size of the clouds monotonically decreases with increasing flow speed in both longitudinal and transverse magnetic fields. This is qualitatively explained by enhancement of hydrodynamic forces washing the nanoclusters away from the clo
Compound droplets can be used in substance encapsulation and material compartmentalization to achieve a precise control over the relevant processes in many applications, such as bioanalysis, pharmaceutical manufacturing, and material synthesis. The flow fields in compound droplets directly affect the performance of these applications, but it is challenging to measure them experimentally. In this study, the flow in compound droplets in axisymmetric microchannels is simulated using the Finite Volume Method, and the interface is captured using the Level Set Method with surface tension accounted for via the Ghost Fluid Method. The combination of the Level Set Method and the Ghost Fluid Method reduces spurious currents that are produced unphysically near the interface, and achieves a precise simulation of the complex flow field within compound droplets. The shape of compound droplets, the vortical patterns, the velocity fields, and the eccentricity are investigated and the effects of the key dimensionless parameters, including the size of the compound droplet, the size of the core droplet, the capillary number, and the viscosity ratio, are analyzed. The flow structures in multi-layered
Application of Microelectronic to bioanalysis is an emerging field which holds great promise. From the standpoint of electronic and system design, biochips imply a radical change of perspective, since new, completely different constraints emerge while other usual constraints can be relaxed. While electronic parts of the system can rely on the usual established design-flow, fluidic and packaging design, calls for a new approach which relies significantly on experiments. We hereby make some general considerations based on our experience in the development of biochips for cell analysis.
Growth hormone (GH) constitutes a set of closely related protein isoforms. In clinical practice, the disagreement of test results between commercially available ligand-binding assays is still an ongoing issue, and incomplete knowledge about the particular function of the different forms leaves an uncertainty of what should be the appropriate measurand. Mass spectrometry is promising to be a way forward. Not only is it capable of providing SI-traceable reference values for the calibration of current GH-tests, but it also offers an independent approach to highly reliable mass-selective quantification of individual GH-isoforms. This capability may add to reliability in doping control too. The article points out why and how.
Background: The increasing prevalence of food allergies requires development of specific and sensitive tests capable of identifying the allergen responsible for the disease. The development of serologic tests that can detect specific IgE antibodies to allergenic proteins would therefore be highly received. Results: Here we present two new quantitative immuno-PCR assays for the sensitive detection of antibodies specific to the shrimp allergen tropomyosin. Both assays are based on the self-assembling Tus-Ter-lock protein-DNA conjugation system. Significantly elevated levels of tropomyosin-specific IgE were detected in sera from patients allergic to shrimp. Conclusions: This is the first time an allergenic protein has been fused with Tus to enable specific IgE antibody detection in human sera by quantitative immuno-PCR.