Quantitative angiography (QA) in two dimensions has been instrumental in assessing neurovascular contrast flow patterns, aiding disease severity and treatment outcome evaluations. However, QA requires high spatio-temporal resolution, restricting its use to digital subtraction angiography (DSA), and is prone to errors in quantification of highly 3D flow patterns. This study examines whether 3D QA information can be recovered by reconstructing four-dimensional (4D) angiography using data from standard clinical imaging protocols. Patient-specific internal carotid aneurysm models were used to generate high-fidelity computational fluid dynamics (CFD) simulations of contrast flow. The resulting 4D angiograms were used to simulate biplane DSA under clinical imaging protocols. 4D angiography was reconstructed from two views using back-projection constrained by an a priori 3D geometry. Quantitative angiographic parametric imaging (API) metrics obtained from the CFD-based 4D angiography and reconstructed 4D angiography were compared using mean square error (MSE) and mean absolute percentage error (MAPE). The reconstructed 4D datasets effectively captured 3D flow dynamics, achieving an averag
Accurate correspondence matching across multiple angiographic views is the prerequisite for 3D coronary reconstruction and interventional guidance. However, the development of robust deep learning models for this task has been stifled by a fundamental data bottleneck. Obtaining ground truth for matching tasks in angiography pairs is prohibitively expensive and hard to scale. To overcome this barrier, we introduce a physically-grounded data generation framework that synthesizes high-fidelity Digital Reconstructed Radiographs (DRRs) from 3D Coronary CT Angiography (CCTA) volumes. Our framework generates dense, highly accurate 3D-to-2D projection labels by simulating realistic C-arm acquisition geometry on patient anatomy at zero human cost. Leveraging this dense supervision, we propose a Geometry-Informed Matching Module (GIMM) that integrates global feature and anatomical structure into correspondence learning. Unlike real angiography where assessment relies on subjective human annotation, our dataset provides 2D correspondence labels with paired images, allowing human-free evaluation. We comprehensively evaluate our method on the proposed CT-derived DRR dataset and demonstrate impr
Coronary angiography is the reference standard for evaluating coronary artery disease, yet visual interpretation remains variable between readers. Existing artificial intelligence methods typically analyze single frames or projections and focus mainly on stenosis, limiting comprehensive coronary assessment. We present DeepCORO-CLIP, a multi-view foundation model trained with video-text contrastive learning on 203,808 angiography videos from 28,117 patients across 32,473 studies at the Montreal Heart Institute and externally validated on 4,249 studies from the University of California, San Francisco. DeepCORO-CLIP integrates multiple projections with attention-based pooling for study-level assessment across diagnostic, prognostic, and disease progression tasks. For significant stenosis detection, the model achieved an AUROC of 0.888 internally and 0.89 on external validation. Mean absolute error against core laboratory quantitative coronary angiography was 13.6%, lower than clinical reports at 19.0%. The model also performed strongly for chronic total occlusion, intracoronary thrombus, and coronary calcification detection. Transfer learning enabled prediction of one-year major adver
Medical image classification is a core task in computer-aided diagnosis (CAD), playing a pivotal role in early disease detection, treatment planning, and patient prognosis assessment. In ophthalmic practice, fluorescein fundus angiography (FFA) and indocyanine green angiography (ICGA) provide hemodynamic and lesion-structural information that conventional fundus photography cannot capture. However, due to the single-modality nature, subtle lesion patterns, and significant inter-device variability, existing methods still face limitations in generalization and high-confidence prediction. To address these challenges, we propose CLEAR-Mamba, an enhanced framework built upon MedMamba with optimizations in both architecture and training strategy. Architecturally, we introduce HaC, a hypernetwork-based adaptive conditioning layer that dynamically generates parameters according to input feature distributions, thereby improving cross-domain adaptability. From a training perspective, we develop RaP, a reliability-aware prediction scheme built upon evidential uncertainty learning, which encourages the model to emphasize low-confidence samples and improves overall stability and reliability. We
Coronary angiography is the main tool for assessing coronary artery disease, but visual grading of stenosis is variable and only moderately related to ischaemia. Wire based fractional flow reserve (FFR) improves lesion selection but is not used systematically. Angiography derived indices such as quantitative flow ratio (QFR) offer wire free physiology, yet many tools are workflow intensive and separate from automated anatomy analysis and virtual PCI planning. We developed AngioAI-QFR, an end to end angiography only pipeline combining deep learning stenosis detection, lumen segmentation, centreline and diameter extraction, per millimetre Relative Flow Capacity profiling, and virtual stenting with automatic recomputation of angiography derived QFR. The system was evaluated in 100 consecutive vessels with invasive FFR as reference. Primary endpoints were agreement with FFR (correlation, mean absolute error) and diagnostic performance for FFR <= 0.80. On held out frames, stenosis detection achieved precision 0.97 and lumen segmentation Dice 0.78. Across 100 vessels, AngioAI-QFR correlated strongly with FFR (r = 0.89, MAE 0.045). The AUC for detecting FFR <= 0.80 was 0.93, with se
Background: Coronary angiography (CAG) is the cornerstone imaging modality for evaluating coronary artery stenosis and guiding interventional decision-making. However, interpretation based on single-frame angiographic images remains highly operator-dependent, and conventional deep learning models still face challenges in modeling complex vascular morphology and fine-grained texture patterns.Methods: We propose a Lightweight Quantum-Enhanced ResNet (LQER) for binary classification of coronary angiography images. A pretrained ResNet18 is employed as a classical feature extractor, while a parameterized quantum circuit (PQC) is introduced at the high-level semantic feature space for quantum feature enhancement. The quantum module utilizes data re-uploading and entanglement structures, followed by residual fusion with classical features, enabling end-to-end hybrid optimization with a strictly controlled number of qubits.Results: On an independent test set, the proposed LQER outperformed the classical ResNet18 baseline in accuracy, AUC, and F1-score, achieving a test accuracy exceeding 90%. The results demonstrate that lightweight quantum feature enhancement improves discrimination of po
Angiography imaging is a medical imaging technique that enhances the visibility of blood vessels within the body by using contrast agents. Angiographic images can effectively assist in the diagnosis of vascular diseases. However, contrast agents may bring extra radiation exposure which is harmful to patients with health risks. To mitigate these concerns, in this paper, we aim to automatically generate angiography from non-angiographic inputs, by leveraging and enhancing the inherent physical properties of vascular structures. Previous methods relying on 2D slice-based angiography synthesis struggle with maintaining continuity in 3D vascular structures and exhibit limited effectiveness across different imaging modalities. We propose VasTSD, a 3D vascular tree-state space diffusion model to synthesize angiography from 3D non-angiographic volumes, with a novel state space serialization approach that dynamically constructs vascular tree topologies, integrating these with a diffusion-based generative model to ensure the generation of anatomically continuous vasculature in 3D volumes. A pre-trained vision embedder is employed to construct vascular state space representations, enabling co
Multi-view reasoning in coronary X-ray angiography is inherently a cross-projection geometric problem, yet automated report generation in this setting remains largely unexplored. The 3D vascular topology leads to projection-dependent branch overlap and foreshortening, rendering single-view modeling fundamentally incomplete and unstable for lesion localization and stenosis grading. Although multi-view fusion appears promising, learning anatomically consistent fusion from real angiograms is impeded by a critical limitation: cross-view alignment is unobservable and cannot be explicitly supervised. Consequently, conventional fusion relies on implicit correlations rather than verified anatomical correspondence. We address this by reformulating multi-view stenosis reporting as an alignment-constrained aggregation problem. A controllable synthetic angiography generation strategy is introduced to expose geometry-derived patch-level correspondence supervision unavailable in real data. An anatomy-correspondence module learns cross-view correspondence matrices that explicitly align auxiliary features within the main-view coordinate space prior to fusion, thereby constraining evidence aggregat
Segmentation of the main coronary artery from X-ray coronary angiography (XCA) sequences is crucial for the diagnosis of coronary artery diseases. However, this task is challenging due to issues such as blurred boundaries, inconsistent radiation contrast, complex motion patterns, and a lack of annotated images for training. Although Semi-Supervised Learning (SSL) can alleviate the annotation burden, conventional methods struggle with complicated temporal dynamics and unreliable uncertainty quantification. To address these challenges, we propose SAM3-based Teacher-student framework with Motion-Aware consistency and Progressive Confidence Regularization (SMART), a semi-supervised vessel segmentation approach for X-ray angiography videos. First, our method utilizes SAM3's unique promptable concept segmentation design and innovates a SAM3-based teacher-student framework to maximize the performance potential of both the teacher and the student. Second, we enhance segmentation by integrating the vessel mask warping technique and motion consistency loss to model complex vessel dynamics. To address the issue of unreliable teacher predictions caused by blurred boundaries and minimal contras
Optical coherence tomography angiography (OCTA) provides non-invasive visualization of retinal microvasculature, but learning robust representations remains challenging due to sparse vessel structures and strong topological constraints. Many existing self-supervised learning approaches, including masked autoencoders, are primarily designed for dense natural images and rely on uniform masking and pixel-level reconstruction, which may inadequately capture vascular geometry. We propose VAMAE, a vessel-aware masked autoencoding framework for self-supervised pretraining on OCTA images. The approach incorporates anatomically informed masking that emphasizes vessel-rich regions using vesselness and skeleton-based cues, encouraging the model to focus on vascular connectivity and branching patterns. In addition, the pretraining objective includes reconstructing multiple complementary targets, enabling the model to capture appearance, structural, and topological information. We evaluate the proposed pretraining strategy on the OCTA-500 benchmark for several vessel segmentation tasks under varying levels of supervision. The results indicate that vessel-aware masking and multi-target reconstru
The scarcity of high-quality imaging data for coronary angiography (CAG) stenosis limits the clinical translation of automated stenosis detection. Synthetic stenosis data provides a practical avenue to augment training sets, improving data quality, diversity, and distributional coverage, and enhancing detection precision and generalization. However, diffusion-based editing commonly relies on soft guidance in a noise-initialized reverse process, offering limited pixel-level precision and structure preservation. We propose the OT-Bridge Editor, which reframes localized editing as a constrained entropic optimal transport (OT) problem and leverages geometric information to steer the generation path, enabling stronger geometric control. Extensive experiments show that our synthesized angiograms consistently improve downstream stenosis detection, yielding substantial relative gains of 27.8% on the public ARCADE benchmark and 23.0% on our multi-center dataset, supported by consistent qualitative results.
Background: Coronary angiography (CAG) is a cornerstone imaging modality for assessing coronary artery disease and guiding interventional treatment decisions. However, in real-world clinical settings, angiographic images are often characterized by complex lesion morphology, severe class imbalance, label uncertainty, and limited computational resources, posing substantial challenges to conventional deep learning approaches in terms of robustness and generalization.Methods: The proposed framework is built upon a pretrained convolutional neural network to construct a lightweight hybrid neural representation. A selective neural plasticity training strategy is introduced to enable efficient parameter adaptation. Furthermore, a brain-inspired attention-modulated loss function, combining Focal Loss with label smoothing, is employed to enhance sensitivity to hard samples and uncertain annotations. Class-imbalance-aware sampling and cosine annealing with warm restarts are adopted to mimic rhythmic regulation and attention allocation mechanisms observed in biological neural systems.Results: Experimental results demonstrate that the proposed lightweight brain-inspired model achieves strong an
The application of iodinated contrast media (ICM) improves the sensitivity and specificity of computed tomography (CT) for a wide range of clinical indications. However, overdose of ICM can cause problems such as kidney damage and life-threatening allergic reactions. Deep learning methods can generate CT images of normal-dose ICM from low-dose ICM, reducing the required dose while maintaining diagnostic power. However, existing methods are difficult to realize accurate enhancement with incompletely paired images, mainly because of the limited ability of the model to recognize specific structures. To overcome this limitation, we propose a Structure-constrained Language-informed Diffusion Model (SLDM), a unified medical generation model that integrates structural synergy and spatial intelligence. First, the structural prior information of the image is effectively extracted to constrain the model inference process, thus ensuring structural consistency in the enhancement process. Subsequently, semantic supervision strategy with spatial intelligence is introduced, which integrates the functions of visual perception and spatial reasoning, thus prompting the model to achieve accurate enha
Accurate segmentation of coronary arteries remains a significant challenge in clinical practice, hindering the ability to effectively diagnose and manage coronary artery disease. The lack of large, annotated datasets for model training exacerbates this issue, limiting the development of automated tools that could assist radiologists. To address this, we introduce CM-UNet, which leverages self-supervised pre-training on unannotated datasets and transfer learning on limited annotated data, enabling accurate disease detection while minimizing the need for extensive manual annotations. Fine-tuning CM-UNet with only 18 annotated images instead of 500 resulted in a 15.2% decrease in Dice score, compared to a 46.5% drop in baseline models without pre-training. This demonstrates that self-supervised learning can enhance segmentation performance and reduce dependence on large datasets. This is one of the first studies to highlight the importance of self-supervised learning in improving coronary artery segmentation from X-ray angiography, with potential implications for advancing diagnostic accuracy in clinical practice. By enhancing segmentation accuracy in X-ray angiography images, the pro
Recent advancements in AI have significantly transformed medical imaging, particularly in angiography, by enhancing diagnostic precision and patient care. However existing works are limited in analyzing the aorta and iliac arteries, above all for vascular anomaly detection and characterization. To close this gap, we propose Dr-SAM, a comprehensive multi-stage framework for vessel segmentation, diameter estimation, and anomaly analysis aiming to examine the peripheral vessels through angiography images. For segmentation we introduce a customized positive/negative point selection mechanism applied on top of the Segment Anything Model (SAM), specifically for medical (Angiography) images. Then we propose a morphological approach to determine the vessel diameters followed by our histogram-driven anomaly detection approach. Moreover, we introduce a new benchmark dataset for the comprehensive analysis of peripheral vessel angiography images which we hope can boost the upcoming research in this direction leading to enhanced diagnostic precision and ultimately better health outcomes for individuals facing vascular issues.
Accurate correspondence matching in coronary angiography images is crucial for reconstructing 3D coronary artery structures, which is essential for precise diagnosis and treatment planning of coronary artery disease (CAD). Traditional matching methods for natural images often fail to generalize to X-ray images due to inherent differences such as lack of texture, lower contrast, and overlapping structures, compounded by insufficient training data. To address these challenges, we propose a novel pipeline that generates realistic paired coronary angiography images using a diffusion model conditioned on 2D projections of 3D reconstructed meshes from Coronary Computed Tomography Angiography (CCTA), providing high-quality synthetic data for training. Additionally, we employ large-scale image foundation models to guide feature aggregation, enhancing correspondence matching accuracy by focusing on semantically relevant regions and keypoints. Our approach demonstrates superior matching performance on synthetic datasets and effectively generalizes to real-world datasets, offering a practical solution for this task. Furthermore, our work investigates the efficacy of different foundation model
Accurate segmentation of vascular structures in coronary angiography remains a core challenge in medical image analysis due to the complexity of elongated, thin, and low-contrast vessels. Classical convolutional neural networks (CNNs) often fail to preserve topological continuity, while recent Vision Transformer (ViT)-based models, although strong in global context modeling, lack precise boundary awareness. In this work, we introduce BAVT, a Boundary-Aware Vision Transformer, a ViT-based architecture enhanced with an edge-aware loss that explicitly guides the segmentation toward fine-grained vascular boundaries. Unlike hybrid transformer-CNN models, BAVT retains a minimal, scalable structure that is fully compatible with large-scale vision foundation model (VFM) pretraining. We validate our approach on the DCA-1 coronary angiography dataset, where BAVT achieves superior performance across medical image segmentation metrics outperforming both CNN and hybrid baselines. These results demonstrate the effectiveness of combining plain ViT encoders with boundary-aware supervision for clinical-grade vascular segmentation.
Coronary microvascular dysfunction (CMD), characterized by impaired regulation of blood flow in the coronary microcirculation, plays a key role in the pathogenesis of ischemic heart disease and is increasingly recognized as a contributor to adverse cardiovascular outcomes. Despite its clinical importance, CMD remains underdiagnosed due to the reliance on invasive procedures such as pressure wire-based measurements of the index of microcirculatory resistance (IMR) and coronary flow reserve (CFR), which are costly, time-consuming, and carry procedural risks. To date, no study has sought to quantify CMD indices using data-driven approaches while leveraging the rich information contained in coronary angiograms. To address these limitations, this study proposes a novel data-driven framework for inference of CMD indices based on coronary angiography. A physiologically validated multi-physics model was used to generate synthetic datasets for data-driven model training, consisting of CMD indices and computational angiograms with corresponding contrast intensity profiles (CIPs). Two neural network architectures were developed: a single-input-channel encoder-MLP model for IMR prediction and
Coronary Microvascular Dysfunction (CMD) is characterized by impaired vasodilation and can lead to insufficient blood flow to the myocardium during stress or exertion, affecting millions of people globally. Despite their diagnostic value, invasive, wire-based diagnosis techniques of CMD, such as index of microcirculatory resistance (IMR) and coronary flow reserve (CFR), are underutilized due to their complexity and inconsistency. Coronary angiography, one of the most commonly used imaging modalities, offers valuable flow information that assists in diagnosing CMD. However, this information is not fully understood or utilized in current clinical practice. In this study, a 3D-0D coupled multi-physics computational fluid dynamics (CFD) model was developed and calibrated to simulate and study the process of contrast injection and washout during clinical angiography. A contrast intensity profile (CIP) was introduced to describe the dynamics of coronary angiography data. Additionally, sensitivity studies were conducted to evaluate the influence of various coronary lumped parameter model (LPM) parameters on the shapes of CIPs. The results demonstrate that the multi-physics model can be ef
Cardiovascular diseases are the leading cause of death globally, with X-ray Coronary Angiography (XCA) as the gold standard during real-time cardiac interventions. Segmentation of coronary vessels from XCA can facilitate downstream quantitative assessments, such as measurement of the stenosis severity and enhancing clinical decision-making. However, developing generalizable vessel segmentation models for XCA is challenging due to variations in imaging protocols and patient demographics that cause domain shifts. These limitations are exacerbated by the lack of annotated datasets, making Single-source Domain Generalization (SDG) a necessary solution for achieving generalization. Existing SDG methods are largely augmentation-based, which may not guarantee the mitigation of overfitting to augmented or synthetic domains. We propose a novel approach, ``AngioDG", to bridge this gap by channel regularization strategy to promote generalization. Our method identifies the contributions of early feature channels to task-specific metrics for DG, facilitating interpretability, and then reweights channels to calibrate and amplify domain-invariant features while attenuating domain-specific ones. W